ABB 1SDA071778R1 E4.2N 3200 Ekip Hi-Touch LSI four-pole fixed air circuit breaker with a 3200 A rated current, 690 V AC rated operational voltage and 66 kA breaking capacity at 400/415 V AC.
£15,684.30
The ABB E4.2N 3200 Ekip Hi-Touch LSI 4p FHR, order code 1SDA071778R1, is a high-performance four-pole Emax 2 air circuit breaker designed for protection, switching, measurement and monitoring in demanding low-voltage electrical distribution systems. Part of the ABB SACE Emax 2 E4.2 series, it combines a 3200 A rated current with the advanced Ekip Hi-Touch LSI electronic trip unit.
The E4.2N performance level provides a rated ultimate short-circuit breaking capacity of 66 kA across a broad operating-voltage range, including at 400/415 V AC. Its Ekip Hi-Touch LSI trip unit provides adjustable long-time overload, selective short-time and instantaneous short-circuit protection, giving engineers comprehensive control over protection settings and coordination within complex electrical networks.
This model is a four-pole fixed circuit breaker with rear horizontal terminals and is rated for operation up to 690 V AC. The Ekip Hi-Touch platform incorporates advanced measurement capabilities, including Ekip Measuring Pro and network analysis functionality, making the breaker particularly suitable for installations requiring both dependable protection and detailed supervision of electrical-system performance.
Air circuit breakers such as the ABB E4.2N protect high-current low-voltage networks against overload and short-circuit conditions while providing the switching performance required by major distribution circuits. The 3200 A current rating, 66 kA breaking capacity and configurable LSI protection functions make the 1SDA071778R1 well suited to installations where selective coordination and continuity of service are important.
The Ekip Hi-Touch trip unit extends conventional circuit protection with sophisticated measurement and network-analysis capabilities. This enables electrical engineers to combine protection, system supervision and power-quality monitoring within the Emax 2 platform, helping improve visibility and management of critical electrical distribution networks.
| Series | SACE Emax 2 E4.2 |
|---|---|
| Order code / MPN | 1SDA071778R1 |
| EAN | 8015644756284 |
| Product type | Air circuit breaker (ACB) |
| Frame / performance level | E4.2N |
| Rated uninterrupted current (Iu) | 3200 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Frequency | 50 / 60 Hz |
| Number of poles | 4 |
| Trip unit | Ekip Hi-Touch LSI |
| Protection functions | Long-time, short-time and instantaneous (LSI) |
| Overload protection adjustment | 1280–3200 A |
| Selective short-circuit protection adjustment | 1920–32000 A |
| Instantaneous short-circuit protection adjustment | 4800–48000 A |
| Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC | 66 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC | 66 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 66 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC | 66 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 66 kA |
| Rated short-time withstand current (Icw), 1 s | 66 kA |
| Measurement | Ekip Measuring Pro |
| Power-quality monitoring | Network Analyzer |
| Execution | Fixed |
| Main terminals | Rear horizontal (FHR) |
| Auxiliary contacts | 4 for open/closed circuit-breaker position |
| Standard | IEC 60947-2 |
The ABB 1SDA071778R1 is an Emax 2 air circuit breaker designed for protection, switching, measurement and monitoring of high-current low-voltage power-distribution systems.
This E4.2N circuit breaker has a rated uninterrupted current of 3200 A.
The Ekip Hi-Touch LSI trip unit provides adjustable long-time overload, selective short-time and instantaneous short-circuit protection.
The E4.2N 3200 has a rated ultimate short-circuit breaking capacity of 66 kA at 400/415 V AC, with a 66 kA rating also specified across its principal operating-voltage range up to 690 V AC.
The 1SDA071778R1 is a fixed four-pole air circuit breaker fitted with rear horizontal terminals and four auxiliary contacts for open/closed position signalling.
ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, high-current switching performance, integrated measurement and network monitoring to provide dependable control and protection for modern low-voltage power-distribution systems.
We use cookies