1SDA071773R1 ABB E4.2N 3200 Ekip Dip LSIG 4p F HR Air Circuit Breaker 3200 A

1SDA071773R1 ABB E4.2N 3200 Ekip Dip LSIG 4p F HR Air Circuit Breaker 3200 A

ABB 1SDA071773R1 E4.2N 3200 Ekip Dip LSIG 4p F HR is a 3200 A four-pole fixed SACE Emax 2 air circuit breaker with Ekip Dip LSIG electronic protection, 66 kA short-circuit breaking capacity and rear horizontal terminals.

SKU: 1SDA071773R1MPN: 1SDA071773R1
Price
List Price £17,774.58 ex VAT
Your Price (ex VAT) Save 25%
£13,330.94 25% OFF
You save £4,443.65 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £13,330.94
Trade pricing is personalised to your account

Manufacturer Lead Time

£13,330.94

Why Choose the ABB E4.2N 3200 Ekip Dip LSIG 4p F HR Air Circuit Breaker?

The ABB E4.2N 3200 Ekip Dip LSIG 4p F HR, order code 1SDA071773R1, is a high-current four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range. Designed for fixed installation in demanding low-voltage power distribution systems, it combines a 3200 A rated uninterrupted current with an Ekip Dip LSIG solid-state electronic release for long-time overload, selective short-time, instantaneous short-circuit and earth-fault protection.

The Ekip Dip LSIG release provides comprehensive adjustable electronic protection using straightforward DIP-switch settings. Long-time protection is adjustable from 0.4–1 × In, selective short-circuit protection from 0.6–10 × In, instantaneous protection from 1.5–15 × In and earth-fault protection from 0.1–1 × In, supporting effective coordination throughout the electrical distribution system.

The E4.2N performance level provides a rated ultimate short-circuit breaking capacity of 66 kA across operating voltages from 380–690 V AC, together with a rated short-time withstand current of 66 kA for 1 s. Its four-pole fixed construction, rear horizontal terminals and four auxiliary contacts make the 1SDA071773R1 a robust solution for high-current industrial, commercial and infrastructure switchboards.

Key Advantages

  • High-current ABB SACE Emax 2 air circuit breaker for demanding low-voltage distribution systems.
  • 3200 A rated uninterrupted current for substantial industrial and commercial electrical loads.
  • Four-pole configuration for simultaneous switching of three phases and neutral.
  • Ekip Dip LSIG electronic trip unit with straightforward DIP-switch adjustment.
  • Provides long-time, selective short-time, instantaneous and earth-fault protection.
  • 66 kA Icu at 380–690 V AC provides consistent short-circuit performance across common low-voltage system voltages.
  • 66 kA Icw for 1 s supports selective protection coordination in high-current distribution systems.
  • Adjustable 0.1–1 × In earth-fault protection adds protection against ground-fault conditions.
  • Fixed construction with rear horizontal terminals for permanent switchboard integration.

Key Features

  • ABB SACE Emax 2 E4.2N series.
  • 3200 A rated uninterrupted current.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 50 / 60 Hz operating frequency.
  • Four-pole fixed air circuit breaker.
  • Ekip Dip LSIG solid-state electronic release.
  • Adjustable long-time overload protection.
  • Adjustable selective short-time short-circuit protection.
  • Adjustable instantaneous short-circuit protection.
  • Adjustable earth-fault protection.
  • Long-time protection adjustment from 0.4–1 × In.
  • Short-time protection adjustment from 0.6–10 × In.
  • Instantaneous protection adjustment from 1.5–15 × In.
  • Earth-fault protection adjustment from 0.1–1 × In.
  • 66 kA Icu at 380–690 V AC.
  • 66 kA Icw for 1 s.
  • Rear horizontal main terminals.
  • Four auxiliary contacts and circuit-breaker open/closed position indication.

Comprehensive LSIG Protection for High-Current Distribution

ABB SACE Emax 2 air circuit breakers provide switching, isolation and electronic protection for high-current low-voltage distribution circuits. With its 3200 A rated uninterrupted current, 66 kA ultimate short-circuit breaking capacity and 66 kA short-time withstand capability for 1 s, the E4.2N 3200 is designed for substantial incoming supplies and distribution feeders where dependable fault interruption and system selectivity are essential.

The Ekip Dip LSIG release combines long-time overload, selective short-time, instantaneous and earth-fault protection within one electronic trip unit. Adjustable DIP-switch settings provide a straightforward method of configuring protection thresholds, helping a correctly engineered distribution system protect cables, switchgear and connected equipment while coordinating operation between upstream and downstream protective devices.

Typical Applications

  • Low-voltage main distribution switchboards.
  • High-current incoming supply circuits.
  • Industrial electrical distribution systems.
  • Manufacturing and process plants.
  • Large commercial building power distribution.
  • Transformer secondary protection.
  • High-current outgoing distribution feeders.
  • Infrastructure and utility installations.
  • Power systems requiring integrated earth-fault protection and selective coordination.

Technical Specifications

Series SACE Emax 2
ABB product group Emax2 Air Circuit Breaker
Frame / type E4.2N
Order code 1SDA071773R1
EAN / GTIN 8015644756239
Product type Air circuit breaker
Rated uninterrupted current (Iu) 3200 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50 / 60 Hz
Number of poles 4
Release Ekip Dip LSIG
Release type Solid-state electronic
Protection functions Long-time, short-time, instantaneous and earth fault (LSIG)
Long-time overload protection setting 0.4–1 × In
Long-time overload adjustment 1280–3200 A
Selective short-circuit protection setting 0.6–10 × In
Instantaneous short-circuit protection setting 1.5–15 × In
Instantaneous protection adjustment 4800–48000 A
Earth-fault protection setting 0.1–1 × In
Earth-fault protection Integrated
Protection adjustment method DIP switches
Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Rated short-time withstand current (Icw) 66 kA for 1 s
Short-circuit performance level N
Version Fixed (F)
Terminal connection Rear horizontal (HR)
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Net weight 70 kg
Reference standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071773R1 used for?

The ABB 1SDA071773R1 is a 3200 A four-pole air circuit breaker designed for switching and protecting high-current low-voltage distribution circuits where configurable LSIG protection, earth-fault protection and selective coordination are required.

What is the current rating of the E4.2N 3200 Ekip Dip LSIG?

The breaker has a rated uninterrupted current of 3200 A and a rated operational voltage of up to 690 V AC.

What protection does the Ekip Dip LSIG release provide?

The Ekip Dip LSIG solid-state electronic release provides long-time overload, selective short-time short-circuit, instantaneous short-circuit and earth-fault protection, with protection settings configured using DIP switches.

What is the breaking capacity of the ABB E4.2N 3200?

The E4.2N 3200 provides a rated ultimate short-circuit breaking capacity of 66 kA at 380–690 V AC and a rated short-time withstand current of 66 kA for 1 s.

Is the ABB 1SDA071773R1 fixed or withdrawable?

The 1SDA071773R1 is a fixed four-pole air circuit breaker with rear horizontal terminals for permanent installation within a low-voltage switchboard.

Trusted High-Current LSIG Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high-current switching, configurable electronic protection and strong short-time withstand performance to provide dependable overload, short-circuit and earth-fault protection for demanding low-voltage electrical distribution systems.