ABB 1SDA071733R1 SACE Emax 2 E4.2V 2000 Ekip Dip LSIG four-pole fixed air circuit breaker rated at 2000 A and 690 V AC with 150 kA breaking capacity at 400–440 V AC and integrated earth-fault protection.
£12,000.75
The ABB E4.2V 2000 Ekip Dip LSIG 4p F HR, order code 1SDA071733R1, is a high-performance four-pole air circuit breaker (ACB) designed for protection and switching in demanding low-voltage power distribution systems. As part of the advanced ABB SACE Emax 2 series, it combines a 2000 A rated uninterrupted current with an Ekip Dip LSIG electronic protection release and the exceptional short-circuit performance of the E4.2V frame.
This fixed circuit breaker incorporates the Ekip Dip LSIG solid-state electronic trip unit, providing long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. The comprehensive LSIG protection package supports effective coordination throughout complex electrical distribution networks, helping safeguard cables, busbars, switchgear and connected equipment against overloads, short circuits and earth faults.
With a rated operational voltage of 690 V AC, an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC and a 100 kA short-time withstand current for 1 s, the E4.2V 2000 is engineered for installations with exceptionally high prospective fault currents. This version features a fixed four-pole construction with rear flat horizontal terminals and is supplied with four auxiliary contacts and circuit-breaker open/closed position indication.
Air circuit breakers such as the ABB SACE Emax 2 protect high-current low-voltage distribution circuits against potentially damaging electrical faults. The E4.2V frame is engineered for systems with exceptionally high prospective short-circuit currents, while the Ekip Dip LSIG release provides comprehensive protection against overloads, short circuits and earth faults to help safeguard cables, busbars, switchgear and connected electrical equipment.
The Ekip Dip LSIG electronic trip unit combines long-time, short-time, instantaneous and earth-fault protection within a robust electronic release. Together with the E4.2V frame's 150 kA Icu at 400–440 V AC and 100 kA Icw for 1 s, the 1SDA071733R1 is particularly suited to main switchboards and high-power distribution systems where selective protection, earth-fault detection and exceptional fault interruption capability are required.
| Range | SACE Emax 2 |
|---|---|
| Series | E4.2V |
| ABB order code | 1SDA071733R1 |
| EAN | 8015644755836 |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 2000 A |
| Rated current (In) | 2000 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Number of poles | 4 |
| Neutral pole current | 100% of Iu |
| Short-circuit performance level | V |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 150 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 150 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 100 kA |
| Service short-circuit breaking capacity (Ics) at 400 V AC | 150 kA |
| Service short-circuit breaking capacity (Ics) at 440 V AC | 150 kA |
| Service short-circuit breaking capacity (Ics) at 690 V AC | 100 kA |
| Ics as percentage of Icu | 100% |
| Short-time withstand current (Icw) | 100 kA for 1 s; 75 kA for 3 s |
| Trip unit | Ekip Dip LSIG |
| Release type | Solid-state electronic |
| Protection functions | Long-time (L), short-time (S), instantaneous (I) and earth-fault (G) |
| Mounting type | Fixed |
| Terminal type | Rear flat horizontal |
| Auxiliary contacts | 4 |
| Power loss | 425 W |
| Mechanical durability | 20,000 operating cycles |
| Electrical durability | 10,000 operating cycles at up to 690 V AC |
| Standard | IEC 60947-2 |
The ABB 1SDA071733R1 is a four-pole air circuit breaker used for switching and protecting high-current low-voltage power distribution circuits against overloads, short circuits and earth faults, particularly in installations with high prospective fault currents.
The E4.2V 2000 Ekip Dip LSIG 4p F HR has a rated uninterrupted current of 2000 A.
The E4.2V provides an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC and 100 kA at 690 V AC.
The Ekip Dip LSIG electronic trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection.
This model is a fixed four-pole circuit breaker with rear flat horizontal terminals, designed for installation within compatible low-voltage switchboards and high-capacity power distribution assemblies.
ABB SACE Emax 2 air circuit breakers are engineered for dependable protection, switching and management of low-voltage power distribution systems, combining comprehensive electronic protection with exceptional short-circuit performance for demanding industrial and infrastructure installations.