1SDA071715R1 ABB E2.2H 2500 Ekip Touch LSI 4-Pole Fixed Air Circuit Breaker

1SDA071715R1 ABB E2.2H 2500 Ekip Touch LSI 4-Pole Fixed Air Circuit Breaker

ABB 1SDA071715R1 Emax 2 E2.2H 2500 is a 2500 A four-pole fixed air circuit breaker with rear horizontal terminals and an Ekip Touch LSI solid-state electronic release providing adjustable long-time, short-time and instantaneous circuit protection.

SKU: 1SDA071715R1MPN: 1SDA071715R1
Price
List Price £16,312.86 ex VAT
Your Price (ex VAT) Save 25%
£12,234.65 25% OFF
You save £4,078.22 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £12,234.65
Trade pricing is personalised to your account

Manufacturer Lead Time

£12,234.65

Why Choose the ABB E2.2H 2500 Ekip Touch LSI 4p FHR Air Circuit Breaker?

The ABB E2.2H 2500 Ekip Touch LSI 4p FHR, order code 1SDA071715R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for switching and selective protection in demanding low-voltage power distribution systems. This fixed four-pole E2.2H configuration combines a 2500 A rated uninterrupted current with ABB's Ekip Touch LSI solid-state electronic trip unit and rear horizontal main terminals.

The Ekip Touch LSI release provides long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection. Its electronic protection platform allows the breaker to protect against sustained overloads and severe faults while the adjustable short-time function supports selective coordination between upstream and downstream protective devices.

The E2.2H performance level is engineered for high-fault-level installations, with an ultimate short-circuit breaking capacity of 100 kA at 400 V AC and E2.2H series performance of 85 kA at 690 V AC. Together with its 690 V AC rated voltage, fixed four-pole construction and rear horizontal terminals, the 1SDA071715R1 is well suited to main switchboards, transformer secondary systems and high-current industrial distribution networks.

Key Advantages

  • 2500 A rated uninterrupted current for high-current low-voltage distribution circuits.
  • E2.2H high-breaking-capacity frame for demanding installations with substantial prospective fault currents.
  • Four-pole configuration supports switching and protection of three-phase systems incorporating the neutral conductor.
  • Ekip Touch LSI electronic release combines long-time, short-time and instantaneous protection.
  • Short-time protection supports selective coordination with downstream protective devices.
  • 100 kA Icu at 400 V AC provides substantial short-circuit interruption capability.
  • Adjustable protection settings allow the breaker response to be matched to the protected distribution circuit.
  • Four changeover auxiliary contacts support breaker status integration with control and monitoring systems.
  • Fixed construction with rear horizontal terminals provides practical integration into high-current switchboards.

Key Features

  • ABB SACE Emax 2 E2.2H frame.
  • 2500 A rated uninterrupted current (Iu).
  • Four-pole fixed air circuit breaker.
  • Ekip Touch LSI solid-state electronic release.
  • Long-time overload protection (L).
  • Short-time short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Overload release adjustment range of 1000–2500 A.
  • Short-time short-circuit adjustment range of 1500–25,000 A.
  • Instantaneous short-circuit adjustment range of 3750–37,500 A.
  • 690 V AC rated voltage.
  • 100 kA Icu at 400 V AC.
  • No integrated ground-fault protection in this LSI configuration.
  • Rear horizontal main-circuit terminals.
  • Bolted main-circuit connection.
  • Four changeover auxiliary contacts.
  • Trip indication provided.
  • Push-button operating mechanism.
  • Optional motor operation capability.
  • IP30 degree of protection.

Selective Protection for High-Current 2500 A Distribution

The ABB SACE Emax 2 E2.2H is engineered for important switching and protection duties where substantial prospective short-circuit currents can occur. Its 2500 A current rating and 100 kA Icu at 400 V AC make this configuration particularly suitable for main distribution points close to transformers and other high-capacity electrical supplies.

The Ekip Touch LSI release combines three complementary protection functions. Long-time protection responds to sustained overloads, short-time protection enables delayed fault clearance to support selective coordination, and instantaneous protection provides rapid interruption of severe short circuits. This combination helps protect conductors and switchgear while supporting coordinated power-distribution designs where continuity of unaffected circuits is important.

Typical Applications

  • Main low-voltage switchboards and power-distribution assemblies.
  • Industrial main incomer protection.
  • Transformer secondary distribution systems.
  • High-current feeder circuits.
  • Manufacturing and process facilities.
  • Data centres and critical power infrastructure.
  • Large commercial and infrastructure electrical systems.
  • High-fault-level networks requiring selective overload and short-circuit protection.

Technical Specifications

Series SACE Emax 2
Frame E2.2H
ABB order code 1SDA071715R1
EAN 8015644755652
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker
Rated uninterrupted current (Iu) 2500 A
Rated voltage 690 V AC
Number of poles 4
Trip unit Ekip Touch LSI
Release technology Solid-state electronic
Protection functions Long-time (L), short-time (S) and instantaneous (I)
Integrated ground-fault protection No
Overload release setting range 1000–2500 A
Short-time short-circuit release setting range 1500–25,000 A
Instantaneous short-circuit release setting range 3750–37,500 A
Ultimate short-circuit breaking capacity (Icu) at 400 V AC, 50 Hz 100 kA
E2.2H breaking capacity at 690 V AC 85 kA
Installation Fixed
Main connection position Rear
Terminal orientation Horizontal
Main-circuit connection Bolted
Changeover auxiliary contacts 4
Trip indication Yes
Operating element Push button
Integrated motor operator No
Optional motor operator Yes
Degree of protection IP30
Power loss 267 W
Product net width 366 mm
Product net height 371 mm
Product net depth 270 mm
Product net weight 53 kg
ABB EcoSolutions Yes
Recyclability rate according to EN 45555 79.1%

Frequently Asked Questions

What is the ABB E2.2H 2500 Ekip Touch LSI 4p FHR used for?

It is a 2500 A four-pole fixed air circuit breaker designed for switching and selective protection of high-current low-voltage distribution circuits, particularly where substantial prospective short-circuit currents are present.

What protection functions does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI solid-state electronic release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What are the protection setting ranges on ABB 1SDA071715R1?

The overload release is adjustable from 1000–2500 A, the short-time short-circuit release from 1500–25,000 A, and the instantaneous short-circuit release from 3750–37,500 A.

What is the breaking capacity of ABB 1SDA071715R1?

The E2.2H 2500 has an ultimate short-circuit breaking capacity of 100 kA at 400 V AC. The E2.2H performance level is rated at 85 kA at 690 V AC.

Is ABB 1SDA071715R1 fixed or withdrawable?

The 1SDA071715R1 is a fixed four-pole air circuit breaker with rear horizontal bolted main terminals, four changeover auxiliary contacts and open/closed breaker position indication.

High-Performance Selective Protection from ABB SACE Emax 2

ABB SACE Emax 2 air circuit breakers combine high-current switching capability, adjustable electronic protection and substantial short-circuit performance to support selective and dependable low-voltage power distribution.