1SDA071706R1 ABB E2.2S 2500 Ekip Touch LSIG 4p F HR Air Circuit Breaker 2500 A

1SDA071706R1 ABB E2.2S 2500 Ekip Touch LSIG 4p F HR Air Circuit Breaker 2500 A

ABB 1SDA071706R1 SACE Emax 2 E2.2S 2500 Ekip Touch LSIG four-pole fixed air circuit breaker rated at 2500 A with 85 kA breaking capacity at 400 V AC and integrated earth-fault protection for low-voltage power distribution.

SKU: 1SDA071706R1MPN: 1SDA071706R1
Price
List Price £16,176.41 ex VAT
Your Price (ex VAT) Save 25%
£12,132.31 25% OFF
You save £4,044.10 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £12,132.31
Trade pricing is personalised to your account

Manufacturer Lead Time

£12,132.31

Why Choose the ABB E2.2S 2500 Ekip Touch LSIG 4p F HR Air Circuit Breaker?

The ABB E2.2S 2500 Ekip Touch LSIG 4p F HR, order code 1SDA071706R1, is a high-performance four-pole air circuit breaker (ACB) designed for protection and switching in low-voltage power distribution systems. As part of the advanced ABB SACE Emax 2 series, it combines a 2500 A rated current with an intelligent Ekip Touch LSIG electronic protection release for dependable operation in demanding industrial, commercial and infrastructure electrical installations.

This fixed circuit breaker incorporates the Ekip Touch LSIG electronic trip unit, providing long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. The Ekip Touch platform provides advanced electronic protection and monitoring capabilities, helping engineers coordinate protection throughout complex low-voltage distribution networks while safeguarding cables, busbars, switchgear and connected equipment.

With a rated current of 2500 A and an S performance level with 85 kA ultimate short-circuit breaking capacity at 400 V AC, the E2.2S 2500 provides substantial fault interruption capability for high-current power distribution systems. This version features a fixed four-pole construction with rear horizontal terminals, making it suitable for integration into compatible low-voltage switchboards and distribution assemblies.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for low-voltage power distribution.
  • 2500 A rated current for demanding high-current electrical installations.
  • Four-pole configuration for switching and protection of three phases and neutral.
  • Advanced Ekip Touch LSIG electronic trip unit with overload, short-time, instantaneous and earth-fault protection.
  • 85 kA ultimate short-circuit breaking capacity at 400 V AC for robust fault interruption.
  • Ekip Touch technology supports advanced protection, measurement and system monitoring.
  • Fixed configuration with rear horizontal terminals for switchboard installation.

Key Features

  • ABB SACE Emax 2 E2.2S series.
  • 2500 A rated current.
  • Four-pole construction.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 85 kA Icu at 400 V AC.
  • 66 kA Ics at 400 V AC.
  • Ekip Touch LSIG electronic protection release.
  • Long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection functions.
  • Adjustable electronic protection settings for coordinated power distribution.
  • Integrated measurement and monitoring capabilities through the Ekip Touch platform.
  • Fixed circuit-breaker construction with rear horizontal terminals.
  • Designed for high-current low-voltage switchboards and power distribution assemblies.

Advanced LSIG Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 protect high-current low-voltage distribution circuits against overloads, short circuits and earth faults. By interrupting fault currents when configured protection thresholds are reached, the circuit breaker helps protect cables, busbars, switchgear and connected electrical equipment while supporting safe and reliable distribution of electrical power.

The Ekip Touch LSIG electronic trip unit combines long-time, short-time, instantaneous and earth-fault protection with the advanced interface and monitoring capabilities of ABB's Ekip Touch platform. Combined with the E2.2S frame's high short-circuit performance, the 1SDA071706R1 is particularly suited to main and distribution switchboards where sophisticated protection, high current capacity and dependable fault interruption are essential.

Typical Applications

  • Main low-voltage electrical distribution switchboards.
  • Industrial power distribution systems.
  • Commercial buildings and infrastructure installations.
  • Manufacturing and process facilities.
  • High-current feeder and distribution circuits.
  • Transformer and generator distribution systems.
  • Systems requiring integrated earth-fault protection.
  • Electrical switchgear and power distribution assemblies.

Technical Specifications

Range SACE Emax 2
Series E2.2S
ABB order code 1SDA071706R1
Product type Air circuit breaker
Rated current 2500 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Frequency 50 / 60 Hz
Number of poles 4
Short-circuit performance level S
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 85 kA
Service short-circuit breaking capacity (Ics) at 400 V AC 66 kA
Trip unit Ekip Touch LSIG
Release type Electronic
Protection functions Long-time (L), short-time (S), instantaneous (I) and earth-fault (G)
Overload protection adjustment 1000–2500 A
Instantaneous short-circuit protection adjustment 3750–37500 A
Mounting type Fixed
Terminal position Rear horizontal
Connection type Bolt connection
Net weight 58 kg
Standard IEC 60947-2
Country of origin Italy

Frequently Asked Questions

What is the ABB 1SDA071706R1 used for?

The ABB 1SDA071706R1 is a four-pole air circuit breaker used for switching and protecting high-current low-voltage power distribution circuits against overloads, short circuits and earth faults.

What is the rated current of this circuit breaker?

The E2.2S 2500 Ekip Touch LSIG 4p F HR has a rated current of 2500 A.

What is the short-circuit breaking capacity of the ABB 1SDA071706R1?

The E2.2S performance level provides an ultimate short-circuit breaking capacity of 85 kA at 400 V AC.

What protection functions does the Ekip Touch LSIG trip unit provide?

The Ekip Touch LSIG electronic trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection.

How is the ABB 1SDA071706R1 installed?

This model is a fixed four-pole circuit breaker with rear horizontal terminals, designed for installation within compatible low-voltage switchboards and power distribution assemblies.

Trusted Power Protection from ABB

ABB SACE Emax 2 air circuit breakers are engineered for dependable protection, switching and management of low-voltage power distribution systems, combining advanced Ekip electronic protection with robust circuit-breaker technology for demanding industrial, commercial and infrastructure installations.