ABB 1SDA071698R1 Emax 2 E2.2N 2500 is a 2500 A four-pole fixed air circuit breaker with rear horizontal terminals and an Ekip Hi-Touch LSI electronic trip unit providing selective protection, integrated measurement and power-quality analysis.
£12,643.90
The ABB E2.2N 2500 Ekip Hi-Touch LSI 4p FHR, order code 1SDA071698R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for advanced protection, measurement and switching in demanding low-voltage power distribution systems. This fixed four-pole E2.2N configuration combines a 2500 A rated current with ABB's Ekip Hi-Touch LSI electronic trip unit and rear horizontal main terminals.
The Ekip Hi-Touch LSI release provides long-time overload (L), short-time selective short-circuit (S) and instantaneous short-circuit (I) protection. Its advanced electronic platform also incorporates Ekip Measuring Pro and Network Analyzer functionality, extending the breaker beyond circuit protection to provide integrated electrical measurement and power-quality analysis.
The E2.2N performance level provides an ultimate short-circuit breaking capacity of 66 kA from 380–690 V AC. With a rated operational voltage of 690 V AC, 1000 V AC insulation voltage and four-pole fixed construction, the 1SDA071698R1 is well suited to main switchboards, transformer secondary distribution, industrial incomers and other high-current networks requiring advanced selective protection and monitoring.
The ABB SACE Emax 2 E2.2N is engineered for important switching and protection duties in high-current low-voltage networks. Its 2500 A current capability and consistent 66 kA ultimate breaking capacity across commonly used low-voltage system voltages make this configuration suitable for main distribution points where fault interruption, selectivity and continuity of supply are important design considerations.
The Ekip Hi-Touch LSI release combines long-time protection against sustained overloads, short-time protection for selective fault coordination and instantaneous protection for rapid interruption of severe short circuits. Integrated Ekip Measuring Pro and Network Analyzer functionality adds advanced electrical measurement and power-quality analysis, supporting informed operation and management of sophisticated power-distribution systems.
| Series | SACE Emax 2 |
|---|---|
| Frame | E2.2N |
| ABB order code | 1SDA071698R1 |
| EAN | 8015644755485 |
| Product group | Emax2 Air Circuit Breaker |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 2500 A |
| Number of poles | 4 |
| Trip unit | Ekip Hi-Touch LSI |
| Release technology | Electronic |
| Protection functions | Long-time (L), short-time (S) and instantaneous (I) |
| Integrated ground-fault protection | No |
| Overload protection adjustment | 1000–2500 A |
| Short-time short-circuit protection adjustment | 1500–25,000 A |
| Instantaneous short-circuit protection adjustment | 3750–37,500 A |
| Measurement | Ekip Measuring Pro |
| Power-quality analysis | Network Analyzer |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated frequency | 50 / 60 Hz |
| Icu at 380 V AC | 66 kA |
| Icu at 400 / 415 V AC | 66 kA |
| Icu at 440 V AC | 66 kA |
| Icu at 500 / 525 V AC | 66 kA |
| Icu at 690 V AC | 66 kA |
| Short-circuit performance level | N |
| Installation | Fixed |
| Main connection position | Rear |
| Terminal orientation | Horizontal |
| Main-circuit connection | Bolted |
| Changeover auxiliary contacts | 4 |
| Trip indicator | Yes |
| Operating mechanism | Push-button |
| Integrated motor operator | No |
| Optional motor operator | Yes |
| Degree of protection | IP30 |
| Power loss | 267 W |
| Gross catalogue weight | 58 kg |
| Country of origin | Italy |
| Standard | IEC 60947-2 |
It is a 2500 A four-pole fixed air circuit breaker designed for advanced protection, switching and monitoring of high-current low-voltage distribution circuits in industrial, commercial and critical-power installations.
The Ekip Hi-Touch LSI electronic release provides long-time overload, short-time selective short-circuit and instantaneous short-circuit protection.
The E2.2N 2500 provides an ultimate short-circuit breaking capacity of 66 kA at 380, 400/415, 440, 500/525 and 690 V AC.
The overload protection range is 1000–2500 A, short-time short-circuit protection is adjustable from 1500–25,000 A, and instantaneous short-circuit protection is adjustable from 3750–37,500 A.
The Ekip Hi-Touch release incorporates Ekip Measuring Pro for advanced electrical measurement together with Network Analyzer functionality for power-quality monitoring and analysis.