1SDA071695R1 ABB E2.2N 2500 Ekip Touch LSI 4p F HR Air Circuit Breaker 2500 A

1SDA071695R1 ABB E2.2N 2500 Ekip Touch LSI 4p F HR Air Circuit Breaker 2500 A

ABB 1SDA071695R1 E2.2N 2500 Ekip Touch LSI 4p F HR is a 2500 A four-pole fixed SACE Emax 2 air circuit breaker with Ekip Touch LSI electronic protection, 66 kA short-circuit breaking capacity and rear flat horizontal terminals.

SKU: 1SDA071695R1MPN: 1SDA071695R1
Price
List Price £13,116.54 ex VAT
Your Price (ex VAT) Save 25%
£9,837.41 25% OFF
You save £3,279.14 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,837.41
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,837.41

Why Choose the ABB E2.2N 2500 Ekip Touch LSI 4p F HR Air Circuit Breaker?

The ABB E2.2N 2500 Ekip Touch LSI 4p F HR, order code 1SDA071695R1, is a high-current four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range. Designed for fixed installation in demanding low-voltage distribution systems, it combines a 2500 A rated uninterrupted current with an Ekip Touch LSI solid-state electronic release for long-time overload, selective short-time and instantaneous short-circuit protection.

The Ekip Touch LSI release provides adjustable electronic protection through a touch-sensitive interface. Long-time overload protection is adjustable from 0.4–1 × In, selective short-circuit protection from 0.6–10 × In and instantaneous short-circuit protection from 1.5–15 × In, supporting effective protection coordination throughout high-current electrical distribution systems.

The E2.2N performance level provides a rated ultimate short-circuit breaking capacity of 66 kA from 380–690 V AC, with a rated short-time withstand current of 66 kA for 1 s and 50 kA for 3 s. Fixed construction, rear flat horizontal terminals and four auxiliary contacts make the breaker well suited to permanent integration within industrial and commercial low-voltage switchboards.

Key Advantages

  • High-current 2500 A ABB SACE Emax 2 air circuit breaker for demanding low-voltage distribution systems.
  • Four-pole configuration for simultaneous switching of three phases and neutral.
  • Ekip Touch LSI electronic release provides long-time, selective short-time and instantaneous protection.
  • 66 kA Icu across key operating voltages from 380–690 V AC.
  • 66 kA short-time withstand current for 1 s supports selective protection coordination.
  • Adjustable protection thresholds enable coordination with downstream protective devices.
  • Touch-sensitive display provides straightforward protection configuration.
  • Fixed construction with rear flat horizontal terminals for practical switchboard integration.

Key Features

  • ABB SACE Emax 2 E2.2N series.
  • 2500 A rated uninterrupted current (Iu).
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 50 / 60 Hz operating frequency.
  • Four-pole fixed air circuit breaker.
  • Ekip Touch LSI solid-state electronic trip unit.
  • Adjustable long-time overload protection.
  • Adjustable selective short-time short-circuit protection.
  • Adjustable instantaneous short-circuit protection.
  • Long-time protection adjustment from 0.4–1 × In.
  • Short-time protection adjustment from 0.6–10 × In.
  • Instantaneous protection adjustment from 1.5–15 × In.
  • 66 kA Icu at 380–690 V AC.
  • 66 kA Icw for 1 s and 50 kA for 3 s.
  • Rear flat horizontal terminals with bolted main-circuit connection.
  • Four auxiliary contacts and circuit-breaker open/closed position indication.

Selective High-Current Protection for Power Distribution

ABB SACE Emax 2 air circuit breakers provide switching, isolation and protection for high-current low-voltage distribution circuits. With its 2500 A current rating, 66 kA ultimate short-circuit breaking capacity and substantial short-time withstand capability, the E2.2N 2500 is suited to main incomers and distribution feeders where dependable fault interruption and system selectivity are essential.

The Ekip Touch LSI release adds selective short-time protection to long-time overload and instantaneous short-circuit protection. This enables more sophisticated coordination between upstream and downstream protective devices, helping a correctly designed distribution system isolate localised faults while maintaining supply to unaffected circuits wherever possible.

Typical Applications

  • Low-voltage main distribution switchboards.
  • High-current incoming supply circuits.
  • Industrial electrical distribution systems.
  • Manufacturing and process plants.
  • Commercial building power distribution.
  • Transformer secondary protection.
  • High-current outgoing distribution feeders.
  • Power distribution systems requiring selective short-circuit coordination.

Technical Specifications

Series SACE Emax 2
ABB product group Emax2 Air Circuit Breaker
Frame / type E2.2N
Order code 1SDA071695R1
EAN 8015644755454
Product type Air circuit breaker
Rated uninterrupted current (Iu) 2500 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50 / 60 Hz
Number of poles 4
Release Ekip Touch LSI
Release type Solid-state electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Long-time overload protection setting 0.4–1 × In
Long-time overload adjustment 1000–2500 A
Selective short-circuit protection setting 0.6–10 × In
Instantaneous short-circuit protection setting 1.5–15 × In
Instantaneous protection adjustment 3750–37500 A
Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw) 66 kA for 1 s / 50 kA for 3 s
Short-circuit performance level N
Version Fixed (F)
Terminal connection Rear flat horizontal (HR)
Terminal type Bolt connection
Main-circuit screw size M12
Main-circuit tightening torque 70 N·m
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Suitable for IT networks Yes, up to 690 V
Reference standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071695R1 used for?

The ABB 1SDA071695R1 is a 2500 A four-pole air circuit breaker designed for switching and protecting high-current low-voltage distribution circuits where configurable LSI protection and selective fault coordination are required.

What is the current rating of the E2.2N 2500 Ekip Touch LSI?

The breaker has a rated uninterrupted current of 2500 A and a rated operational voltage of up to 690 V AC.

What protection does the Ekip Touch LSI release provide?

The Ekip Touch LSI electronic trip unit provides long-time overload, selective short-time short-circuit and instantaneous short-circuit protection, with adjustable thresholds for coordination with the electrical installation.

What is the breaking capacity of the ABB E2.2N 2500?

The E2.2N 2500 provides a rated ultimate short-circuit breaking capacity of 66 kA from 380–690 V AC, with a rated short-time withstand current of 66 kA for 1 s and 50 kA for 3 s.

Is the ABB 1SDA071695R1 fixed or withdrawable?

The 1SDA071695R1 is a fixed four-pole air circuit breaker with rear flat horizontal terminals and bolted main-circuit connections for permanent installation within a low-voltage switchboard.