ABB 1SDA071693R1 SACE Emax 2 E2.2N 2500 Ekip Dip LSIG four-pole fixed air circuit breaker rated at 2500 A and 690 V AC with 66 kA breaking capacity and integrated earth-fault protection for low-voltage power distribution.
£10,275.92
The ABB E2.2N 2500 Ekip Dip LSIG 4p F HR, order code 1SDA071693R1, is a high-performance four-pole air circuit breaker (ACB) designed for protection and switching in low-voltage power distribution systems. As part of the advanced ABB SACE Emax 2 series, it combines a 2500 A rated uninterrupted current with an Ekip Dip LSIG electronic protection release for dependable operation in demanding industrial, commercial and infrastructure electrical installations.
This fixed circuit breaker incorporates the Ekip Dip LSIG solid-state electronic trip unit, providing long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. Protection settings are configured using DIP switches, enabling the breaker to provide coordinated protection for cables, busbars, switchgear and connected equipment within complex low-voltage distribution networks.
With a rated operational voltage of 690 V AC and an N performance level with 66 kA ultimate short-circuit breaking capacity at 400 V AC, the E2.2N 2500 provides substantial fault interruption capability for high-current distribution systems. This version features a fixed four-pole construction with rear flat horizontal terminals and is fitted with four auxiliary contacts and circuit-breaker open/closed position indication.
Air circuit breakers such as the ABB SACE Emax 2 protect high-current low-voltage distribution circuits against overloads, short circuits and other potentially damaging electrical faults. By interrupting fault currents when configured protection thresholds are reached, the circuit breaker helps protect cables, busbars, switchgear and connected equipment while supporting safe and reliable distribution of electrical power.
The Ekip Dip LSIG electronic trip unit adds earth-fault protection to the long-time, short-time and instantaneous functions provided by LSI releases. This comprehensive protection package, combined with the E2.2N frame's 66 kA breaking capacity, makes the 1SDA071693R1 particularly suitable for main and distribution switchboards where selective protection, high current capacity and dependable fault interruption are essential.
| Range | SACE Emax 2 |
|---|---|
| Series | E2.2N |
| ABB order code | 1SDA071693R1 |
| EAN | 8015644755430 |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 2500 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Frequency | 50 / 60 Hz |
| Number of poles | 4 |
| Neutral pole current | 100% of Iu |
| Short-circuit performance level | N |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 66 kA |
| Service short-circuit breaking capacity (Ics) at 400 V AC | 66 kA |
| Ics as percentage of Icu | 100% |
| Short-time withstand current (Icw) | 66 kA for 1 s; 50 kA for 3 s |
| Trip unit | Ekip Dip LSIG |
| Release type | Electronic |
| Protection functions | Long-time (L), short-time (S), instantaneous (I) and earth-fault (G) |
| Overload protection adjustment | 0.4–1 × In |
| Instantaneous protection adjustment | 1.5–15 × In |
| Earth-fault protection adjustment | 0.1–1 × In |
| Mounting type | Fixed |
| Terminal type | Rear flat horizontal, bolt connection |
| Power loss | 267 W |
| Mechanical durability | 20,000 operating cycles |
| Dimensions (H × W × D) | 371 × 366 × 270 mm |
| Net weight | 53 kg |
| Standard | IEC 60947-2 |
The ABB 1SDA071693R1 is a four-pole air circuit breaker used for switching and protecting high-current low-voltage power distribution circuits against overloads, short circuits and earth faults.
The E2.2N 2500 Ekip Dip LSIG 4p F HR has a rated uninterrupted current of 2500 A.
The E2.2N has an ultimate short-circuit breaking capacity of 66 kA at 400 V AC, with a service breaking capacity of 66 kA at the same voltage.
The Ekip Dip LSIG electronic trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection.
This model is a fixed four-pole circuit breaker with rear flat horizontal terminals, designed for installation within compatible low-voltage switchboards and power distribution assemblies.
ABB SACE Emax 2 air circuit breakers are engineered for dependable protection, switching and management of low-voltage power distribution systems, combining electronic LSIG protection with robust circuit-breaker technology for demanding industrial, commercial and infrastructure installations.