ABB 1SDA071656R1 E2.2B 2000 Ekip Touch LSIG four-pole fixed air circuit breaker with a 2000 A rated current, 42 kA breaking capacity at 400/415 V AC, LSIG electronic protection and rear horizontal flat terminals.
£8,214.89
The ABB E2.2B 2000 Ekip Touch LSIG 4p FHR, order code 1SDA071656R1, is a high-performance four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for protection and control of high-current low-voltage electrical distribution systems. Combining a 2000 A rated uninterrupted current with the advanced Ekip Touch LSIG electronic trip unit, it provides comprehensive overload, selective short-circuit, instantaneous short-circuit and earth-fault protection.
This E2.2B circuit breaker is supplied in a fixed four-pole configuration with rear horizontal flat terminals. Its Ekip Touch LSIG solid-state electronic release provides configurable LSIG protection through ABB's advanced touch-interface platform, supporting straightforward commissioning, protection adjustment and monitoring within modern electrical distribution systems.
With a 2000 A rated uninterrupted current and a rated ultimate short-circuit breaking capacity of 42 kA at 400/415 V AC, the 1SDA071656R1 provides dependable protection for substantial electrical loads. The E2.2B maintains a 42 kA ultimate breaking capacity at 690 V AC and provides a rated short-time withstand current of 42 kA for 1 second, making it suitable for a broad range of industrial, commercial and infrastructure switchboards.
Air circuit breakers such as the ABB SACE Emax 2 E2.2B provide switching, isolation and protection for high-current low-voltage distribution circuits. They are commonly installed as incoming, outgoing or bus-coupler breakers in main distribution assemblies, where reliable interruption of overload, short-circuit and earth-fault currents is essential for protecting electrical equipment and maintaining continuity of supply.
The Ekip Touch LSIG electronic trip unit combines configurable long-time, short-time, instantaneous and earth-fault protection with an intuitive touch-based interface. Together with the Emax 2 platform, these functions enable effective protection coordination across complex electrical networks while providing the flexibility required for modern industrial, commercial and infrastructure power distribution systems.
| Series | SACE Emax 2 |
|---|---|
| Frame / product group | E2.2B |
| ABB order code | 1SDA071656R1 |
| EAN | 8015644755065 |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 2000 A |
| Number of poles | 4 |
| Trip unit | Ekip Touch LSIG |
| Release type | Electronic |
| Protection functions | LSIG – long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection |
| Overload release setting range | 800–2000 A |
| Short-time delayed short-circuit release setting range | 1200–20000 A |
| Instantaneous short-circuit release setting range | 3000–30000 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 525 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 42 kA |
| Rated service short-circuit breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw, 1 s) | 42 kA |
| Rated short-time withstand current (Icw, 3 s) | 42 kA |
| Short-circuit performance level | B |
| Installation | Fixed |
| Terminal arrangement | Rear flat horizontal |
| Main-circuit connection | Bolted |
| Auxiliary contacts | 4 changeover contacts |
| Integrated earth-fault protection | Yes |
| Suitable for IT networks | Yes, up to 690 V |
| Motor drive | Optional |
| Dimensions (H × W × D) | 366 × 371 × 270 mm |
| Applicable standard | IEC 60947-2 |
The ABB 1SDA071656R1 is a 2000 A four-pole air circuit breaker designed to protect and control high-current low-voltage distribution circuits in industrial, commercial and infrastructure installations.
The E2.2B 2000 supplied under ABB order code 1SDA071656R1 has a rated uninterrupted current of 2000 A.
The circuit breaker is fitted with an Ekip Touch LSIG electronic trip unit, providing long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection.
The E2.2B 2000 has a rated ultimate short-circuit breaking capacity of 42 kA at 400/415 V AC, with the 42 kA rating maintained at operating voltages up to 690 V AC.
The 1SDA071656R1 is a fixed air circuit breaker with four poles and rear horizontal flat terminals, intended for permanent installation within compatible low-voltage switchgear and distribution assemblies.
ABB SACE Emax 2 air circuit breakers combine robust fault-interruption performance with advanced electronic protection, making the E2.2B with Ekip Touch LSIG a dependable choice for demanding low-voltage distribution systems requiring comprehensive overload, short-circuit and earth-fault protection.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.