1SDA071656R1 ABB E2.2B 2000 Ekip Touch LSIG 4p FHR Air Circuit Breaker

1SDA071656R1 ABB E2.2B 2000 Ekip Touch LSIG 4p FHR Air Circuit Breaker

ABB 1SDA071656R1 E2.2B 2000 Ekip Touch LSIG four-pole fixed air circuit breaker with a 2000 A rated current, 42 kA breaking capacity at 400/415 V AC, LSIG electronic protection and rear horizontal flat terminals.

SKU: 1SDA071656R1MPN: 1SDA071656R1
Price
List Price £10,953.18 ex VAT
Your Price (ex VAT) Save 25%
£8,214.89 25% OFF
You save £2,738.30 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,214.89
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,214.89

Why Choose the ABB E2.2B 2000 Ekip Touch LSIG 4p FHR Air Circuit Breaker?

The ABB E2.2B 2000 Ekip Touch LSIG 4p FHR, order code 1SDA071656R1, is a high-performance four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for protection and control of high-current low-voltage electrical distribution systems. Combining a 2000 A rated uninterrupted current with the advanced Ekip Touch LSIG electronic trip unit, it provides comprehensive overload, selective short-circuit, instantaneous short-circuit and earth-fault protection.

This E2.2B circuit breaker is supplied in a fixed four-pole configuration with rear horizontal flat terminals. Its Ekip Touch LSIG solid-state electronic release provides configurable LSIG protection through ABB's advanced touch-interface platform, supporting straightforward commissioning, protection adjustment and monitoring within modern electrical distribution systems.

With a 2000 A rated uninterrupted current and a rated ultimate short-circuit breaking capacity of 42 kA at 400/415 V AC, the 1SDA071656R1 provides dependable protection for substantial electrical loads. The E2.2B maintains a 42 kA ultimate breaking capacity at 690 V AC and provides a rated short-time withstand current of 42 kA for 1 second, making it suitable for a broad range of industrial, commercial and infrastructure switchboards.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker for high-current low-voltage power distribution.
  • 2000 A rated uninterrupted current for substantial industrial and commercial electrical loads.
  • Four-pole configuration for three-phase distribution systems requiring neutral switching.
  • Ekip Touch LSIG electronic trip unit provides comprehensive overload, short-circuit and earth-fault protection.
  • 42 kA ultimate breaking capacity at 400/415 V AC for dependable fault interruption.
  • 42 kA ultimate breaking capacity at 690 V AC extends protection capability across higher-voltage LV networks.
  • 42 kA short-time withstand current for 1 second supports coordinated protection strategies.
  • Fixed installation with rear horizontal flat terminals for integration into compatible switchboards.

Key Features

  • ABB SACE Emax 2 E2.2B series.
  • 2000 A rated uninterrupted current.
  • Four-pole air circuit breaker.
  • Ekip Touch LSIG solid-state electronic protection release.
  • Long-time overload protection (L).
  • Selective short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Integrated earth-fault protection (G).
  • Overload release setting range of 800–2000 A.
  • Short-time delayed short-circuit setting range of 1200–20000 A.
  • Instantaneous short-circuit setting range of 3000–30000 A.
  • 42 kA ultimate breaking capacity at 400/415 V AC.
  • 42 kA short-time withstand current for 1 and 3 seconds.
  • Fixed mounting configuration with rear horizontal flat terminals.
  • Four auxiliary changeover contacts for signalling and control.

Advanced High-Current Power Distribution Protection

Air circuit breakers such as the ABB SACE Emax 2 E2.2B provide switching, isolation and protection for high-current low-voltage distribution circuits. They are commonly installed as incoming, outgoing or bus-coupler breakers in main distribution assemblies, where reliable interruption of overload, short-circuit and earth-fault currents is essential for protecting electrical equipment and maintaining continuity of supply.

The Ekip Touch LSIG electronic trip unit combines configurable long-time, short-time, instantaneous and earth-fault protection with an intuitive touch-based interface. Together with the Emax 2 platform, these functions enable effective protection coordination across complex electrical networks while providing the flexibility required for modern industrial, commercial and infrastructure power distribution systems.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Commercial and infrastructure electrical installations.
  • Incoming and outgoing feeder protection.
  • Bus-coupler and distribution circuit applications.
  • Transformer and generator distribution systems.
  • Data centres and critical power installations.
  • Manufacturing and process industry switchgear.

Technical Specifications

Series SACE Emax 2
Frame / product group E2.2B
ABB order code 1SDA071656R1
EAN 8015644755065
Product type Air circuit breaker
Rated uninterrupted current (Iu) 2000 A
Number of poles 4
Trip unit Ekip Touch LSIG
Release type Electronic
Protection functions LSIG – long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection
Overload release setting range 800–2000 A
Short-time delayed short-circuit release setting range 1200–20000 A
Instantaneous short-circuit release setting range 3000–30000 A
Rated operational voltage (Ue) 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 42 kA
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 42 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 42 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC 42 kA
Rated ultimate short-circuit breaking capacity (Icu) at 525 V AC 42 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 42 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw, 1 s) 42 kA
Rated short-time withstand current (Icw, 3 s) 42 kA
Short-circuit performance level B
Installation Fixed
Terminal arrangement Rear flat horizontal
Main-circuit connection Bolted
Auxiliary contacts 4 changeover contacts
Integrated earth-fault protection Yes
Suitable for IT networks Yes, up to 690 V
Motor drive Optional
Dimensions (H × W × D) 366 × 371 × 270 mm
Applicable standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071656R1 used for?

The ABB 1SDA071656R1 is a 2000 A four-pole air circuit breaker designed to protect and control high-current low-voltage distribution circuits in industrial, commercial and infrastructure installations.

What is the rated current of the ABB E2.2B 2000?

The E2.2B 2000 supplied under ABB order code 1SDA071656R1 has a rated uninterrupted current of 2000 A.

What protection unit is fitted to the 1SDA071656R1?

The circuit breaker is fitted with an Ekip Touch LSIG electronic trip unit, providing long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection.

What is the breaking capacity of the ABB E2.2B 2000?

The E2.2B 2000 has a rated ultimate short-circuit breaking capacity of 42 kA at 400/415 V AC, with the 42 kA rating maintained at operating voltages up to 690 V AC.

Is the ABB 1SDA071656R1 fixed or withdrawable?

The 1SDA071656R1 is a fixed air circuit breaker with four poles and rear horizontal flat terminals, intended for permanent installation within compatible low-voltage switchgear and distribution assemblies.

Trusted ABB Protection for High-Current Power Systems

ABB SACE Emax 2 air circuit breakers combine robust fault-interruption performance with advanced electronic protection, making the E2.2B with Ekip Touch LSIG a dependable choice for demanding low-voltage distribution systems requiring comprehensive overload, short-circuit and earth-fault protection.