1SDA071651R1 ABB E2.2B 2000 Ekip Dip LI 4p F HR Air Circuit Breaker 2000 A

1SDA071651R1 ABB E2.2B 2000 Ekip Dip LI 4p F HR Air Circuit Breaker 2000 A

ABB 1SDA071651R1 E2.2B 2000 Ekip Dip LI 4p F HR is a 2000 A four-pole fixed SACE Emax 2 air circuit breaker with Ekip Dip LI electronic overload and instantaneous short-circuit protection and rear horizontal terminals.

SKU: 1SDA071651R1MPN: 1SDA071651R1
Price
List Price £9,822.77 ex VAT
Your Price (ex VAT) Save 25%
£7,367.08 25% OFF
You save £2,455.69 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,367.08
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,367.08

Why Choose the ABB E2.2B 2000 Ekip Dip LI 4p F HR Air Circuit Breaker?

The ABB E2.2B 2000 Ekip Dip LI 4p F HR, order code 1SDA071651R1, is a four-pole air circuit breaker (ACB) designed for reliable switching and protection in high-current low-voltage electrical distribution systems. Part of the ABB SACE Emax 2 series, it combines a 2000 A rated current with an Ekip Dip LI electronic trip unit for dependable overload and instantaneous short-circuit protection.

The Ekip Dip LI release provides long-time overload and instantaneous short-circuit protection with adjustable thresholds. This straightforward electronic protection arrangement makes the breaker particularly suitable for installations requiring dependable circuit protection without the more extensive measurement and communication functions associated with higher-level Ekip releases.

With a four-pole configuration, fixed construction and rear horizontal terminals, the E2.2B 2000 is designed for integration into low-voltage switchboards and power distribution assemblies. The E2.2B performance level provides dependable short-circuit interruption for industrial, commercial and infrastructure applications while the four-pole arrangement enables simultaneous switching of the three phases and neutral.

Key Advantages

  • Reliable ABB SACE Emax 2 air circuit breaker for high-current low-voltage distribution.
  • 2000 A rated current for substantial industrial and commercial electrical loads.
  • Four-pole configuration for switching and protection of three phases and neutral.
  • Ekip Dip LI electronic trip unit for dependable circuit protection.
  • Provides long-time overload and instantaneous short-circuit protection.
  • Adjustable protection thresholds allow coordination with the protected electrical circuit.
  • Fixed construction provides a robust solution for permanent switchboard installations.
  • Rear horizontal terminals support practical busbar and switchboard integration.

Key Features

  • ABB SACE Emax 2 E2.2B series.
  • 2000 A rated current.
  • Four-pole fixed air circuit breaker.
  • Ekip Dip LI electronic trip unit.
  • Long-time overload protection.
  • Instantaneous short-circuit protection.
  • Adjustable electronic protection settings.
  • B short-circuit performance level.
  • Rear horizontal main terminals.
  • Designed for fixed installation within low-voltage switchgear assemblies.
  • Suitable for incoming, feeder and general power-distribution protection.
  • Part of ABB's modular SACE Emax 2 circuit-breaker platform.

Reliable High-Current Power Distribution Protection

Air circuit breakers such as the ABB SACE Emax 2 are used to switch, isolate and protect high-current low-voltage distribution circuits. With its 2000 A current rating, the E2.2B 2000 is suited to substantial incoming and feeder circuits, helping protect switchboards, cables, transformers and connected electrical equipment against overload and short-circuit conditions.

The Ekip Dip LI electronic release provides an effective combination of long-time overload and instantaneous short-circuit protection. Its adjustable electronic settings allow the breaker to be coordinated with the characteristics of the protected circuit, while the fixed four-pole construction and rear horizontal terminals make it well suited to permanent installation in industrial and commercial switchgear.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial electrical distribution systems.
  • Commercial building power distribution.
  • Manufacturing and process plants.
  • Transformer secondary protection.
  • Incoming and outgoing distribution feeders.
  • Infrastructure and utility installations.
  • Power distribution centres and fixed switchgear assemblies.

Technical Specifications

Series SACE Emax 2
ABB product group Emax2 Air Circuit Breaker
Frame / type E2.2B
Order code 1SDA071651R1
Product type Air circuit breaker
Rated current 2000 A
Number of poles 4
Release Ekip Dip LI
Release type Electronic
Protection functions Long-time and instantaneous (LI)
Long-time overload protection Adjustable
Instantaneous short-circuit protection Adjustable
Short-circuit performance level B
Version Fixed (F)
Terminal connection Rear horizontal (HR)
Installation Fixed switchboard mounting
Reference standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071651R1 used for?

The ABB 1SDA071651R1 is a 2000 A four-pole air circuit breaker used for switching and protecting high-current low-voltage power distribution circuits in industrial, commercial and infrastructure installations.

What is the current rating of the E2.2B 2000 Ekip Dip LI?

The circuit breaker has a rated current of 2000 A, making it suitable for substantial incoming and feeder circuits in low-voltage power distribution systems.

What protection does the Ekip Dip LI release provide?

The Ekip Dip LI electronic trip unit provides adjustable long-time overload protection and instantaneous short-circuit protection.

What does LI mean on the ABB Ekip Dip trip unit?

LI identifies the two principal protection functions provided by this release: long-time overload protection (L) and instantaneous short-circuit protection (I).

Is the ABB 1SDA071651R1 fixed or withdrawable?

The 1SDA071651R1 is a fixed four-pole air circuit breaker with rear horizontal terminals for permanent installation within a low-voltage switchboard.

Trusted Low-Voltage Power Protection from ABB

ABB SACE Emax 2 air circuit breakers combine robust switching performance, configurable electronic protection and flexible installation options to provide dependable protection for modern low-voltage electrical distribution systems.