1SDA071643R1 ABB E2.2H 1600 Ekip Dip LSIG 4p FHR Air Circuit Breaker

1SDA071643R1 ABB E2.2H 1600 Ekip Dip LSIG 4p FHR Air Circuit Breaker

ABB 1SDA071643R1 E2.2H 1600 Ekip Dip LSIG four-pole fixed air circuit breaker with a 1600 A rated current, 100 kA breaking capacity at 400/415 V AC, LSIG electronic protection and rear horizontal flat terminals.

SKU: 1SDA071643R1MPN: 1SDA071643R1
Price
List Price £10,465.96 ex VAT
Your Price (ex VAT) Save 25%
£7,849.47 25% OFF
You save £2,616.49 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,849.47
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,849.47

Why Choose the ABB E2.2H 1600 Ekip Dip LSIG 4p FHR Air Circuit Breaker?

The ABB E2.2H 1600 Ekip Dip LSIG 4p FHR, order code 1SDA071643R1, is a high-performance four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for protection and control of demanding low-voltage electrical distribution systems. Combining a 1600 A rated uninterrupted current with an Ekip Dip LSIG electronic trip unit, it provides comprehensive overload, selective short-circuit, instantaneous short-circuit and earth-fault protection for industrial, commercial and infrastructure power systems.

This E2.2H circuit breaker is supplied in a fixed four-pole configuration with rear horizontal flat terminals. Its Ekip Dip LSIG solid-state electronic release provides long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection, with DIP-switch adjustment providing a straightforward method of configuring protection settings during commissioning and maintenance.

With a 1600 A rated uninterrupted current, an H short-circuit performance level and a rated ultimate short-circuit breaking capacity of 100 kA at 400/415 V AC, the 1SDA071643R1 is engineered for high-fault-level distribution duties. It maintains an ultimate breaking capacity of 85 kA at 690 V AC and provides a rated short-time withstand current of 85 kA for 1 second, supporting robust protection and selective coordination in demanding switchboards.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage power distribution.
  • 1600 A rated uninterrupted current for substantial industrial and commercial electrical loads.
  • Four-pole configuration with the neutral pole rated at 100% of uninterrupted current.
  • Ekip Dip LSIG electronic trip unit provides overload, selective short-circuit, instantaneous short-circuit and earth-fault protection.
  • 100 kA ultimate breaking capacity at 400/415 V AC for high prospective fault currents.
  • 85 kA ultimate breaking capacity at 690 V AC for demanding higher-voltage LV networks.
  • 85 kA short-time withstand current for 1 second supports selective protection strategies.
  • Fixed installation with rear horizontal flat terminals for switchboard integration.

Key Features

  • ABB SACE Emax 2 E2.2H series.
  • 1600 A rated uninterrupted current.
  • Four-pole air circuit breaker.
  • Ekip Dip LSIG solid-state electronic protection release.
  • Long-time overload protection (L).
  • Selective short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Integrated earth-fault protection (G).
  • Overload protection adjustable from 0.4–1 × In.
  • Selective short-circuit protection adjustable from 0.6–10 × In.
  • Instantaneous protection adjustable from 1.5–15 × In.
  • Earth-fault protection adjustable from 0.1–1 × In.
  • 100 kA ultimate breaking capacity at 400/415 V AC.
  • 85 kA ultimate breaking capacity at 690 V AC.
  • 1000 V AC rated insulation voltage and 12 kV impulse withstand voltage.
  • Fixed mounting configuration with rear horizontal flat terminals.

Comprehensive High-Fault-Level Circuit Protection

Air circuit breakers such as the ABB SACE Emax 2 E2.2H provide switching, isolation and protection for high-current low-voltage distribution circuits. They are commonly installed as incoming, outgoing or bus-coupler breakers in main switchboards where dependable interruption of overload, short-circuit and earth-fault currents is essential for protecting equipment and maintaining continuity of supply.

The Ekip Dip LSIG electronic trip unit combines comprehensive electronic protection with straightforward DIP-switch adjustment. Its long-time, selective short-circuit, instantaneous and earth-fault functions enable the breaker to respond to a broad range of electrical faults, while the high breaking and short-time withstand capabilities of the E2.2H platform support effective selectivity and protection coordination in demanding electrical networks.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Commercial and infrastructure electrical installations.
  • Incoming and outgoing feeder protection.
  • Bus-coupler and distribution circuit applications.
  • Transformer and generator distribution systems.
  • Data centres and critical power installations.
  • Installations with high prospective short-circuit currents.

Technical Specifications

Series SACE Emax 2
Frame / product group E2.2H
ABB order code 1SDA071643R1
EAN 8015644754938
Product type Air circuit breaker
Rated uninterrupted current (Iu) 1600 A
Rated current (In) 1600 A
Number of poles 4
Neutral pole current 100% of Iu
Trip unit Ekip Dip LSIG
Release type Electronic
Protection functions LSIG – long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection
Overload protection adjustment 0.4–1 × In
Selective short-circuit protection adjustment 0.6–10 × In
Instantaneous short-circuit protection adjustment 1.5–15 × In
Earth-fault protection adjustment 0.1–1 × In
Protection setting method DIP switches
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 85 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw, 1 s) 85 kA
Rated short-time withstand current (Icw, 3 s) 66 kA
Short-circuit performance level H
Frequency 50 / 60 Hz
Current type AC
Installation Fixed
Terminal arrangement Rear flat horizontal
Terminal type Bolted
Connecting capacity 1200 mm²
Integrated earth-fault protection Yes
Suitable for IT networks Yes, up to 690 V
Power loss 136 W
Mechanical durability 25,000 cycles
Electrical durability at up to 440 V AC 12,000 cycles
Electrical durability at 500–690 V AC 10,000 cycles
Applicable standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071643R1 used for?

The ABB 1SDA071643R1 is a 1600 A four-pole air circuit breaker designed to protect and control high-current low-voltage distribution circuits, particularly where high short-circuit breaking performance and comprehensive LSIG protection are required.

What is the rated current of the ABB E2.2H 1600?

The E2.2H 1600 supplied under ABB order code 1SDA071643R1 has a rated uninterrupted current of 1600 A.

What protection unit is fitted to the 1SDA071643R1?

The circuit breaker is fitted with an Ekip Dip LSIG electronic trip unit, providing long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection with settings configured using DIP switches.

What is the breaking capacity of the ABB E2.2H 1600?

The E2.2H 1600 has a rated ultimate short-circuit breaking capacity of 100 kA at 400/415 V AC and 85 kA at 690 V AC, with an 85 kA short-time withstand current for 1 second.

Is the ABB 1SDA071643R1 fixed or withdrawable?

The 1SDA071643R1 is a fixed air circuit breaker with four poles and rear horizontal flat terminals, intended for permanent installation within compatible low-voltage switchgear and distribution assemblies.

Trusted ABB Protection for High-Current Power Systems

ABB SACE Emax 2 air circuit breakers combine high fault-interruption performance with comprehensive electronic protection, making the E2.2H with Ekip Dip LSIG a robust choice for demanding low-voltage distribution systems requiring overload, short-circuit and earth-fault protection.