1SDA071641R1 ABB E2.2H 1600 Ekip Dip LI 4-Pole Fixed Air Circuit Breaker

1SDA071641R1 ABB E2.2H 1600 Ekip Dip LI 4-Pole Fixed Air Circuit Breaker

ABB 1SDA071641R1 Emax 2 E2.2H 1600 is a 1600 A four-pole fixed air circuit breaker with rear horizontal terminals and an Ekip Dip LI electronic trip unit providing adjustable long-time overload and instantaneous short-circuit protection.

SKU: 1SDA071641R1MPN: 1SDA071641R1
Price
List Price £9,374.53 ex VAT
Your Price (ex VAT) Save 25%
£7,030.90 25% OFF
You save £2,343.63 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,030.90
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,030.90

Why Choose the ABB E2.2H 1600 Ekip Dip LI 4p FHR Air Circuit Breaker?

The ABB E2.2H 1600 Ekip Dip LI 4p FHR, order code 1SDA071641R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for switching and protection in demanding low-voltage AC power distribution systems. This fixed four-pole E2.2H configuration combines a 1600 A rated current with ABB's Ekip Dip LI electronic trip unit and rear horizontal main terminals.

The Ekip Dip LI release provides long-time overload (L) and instantaneous short-circuit (I) protection. Protection thresholds are configured using DIP switches, providing a straightforward electronic protection solution with overload adjustment from 0.4–1 × In and instantaneous protection adjustment from 1.5–15 × In.

The E2.2H performance level provides an ultimate short-circuit breaking capacity of 100 kA at 380–440 V AC and 85 kA at 500–690 V AC. With a rated operational voltage of 690 V AC, fixed construction and four-pole switching, the 1SDA071641R1 is well suited to main switchboards, transformer secondary systems, industrial incomers and other high-current distribution circuits with substantial prospective fault levels.

Key Advantages

  • 1600 A rated current for high-current low-voltage power distribution.
  • E2.2H high-breaking-capacity performance for demanding fault-level applications.
  • Four-pole configuration supports switching and protection of three-phase systems incorporating the neutral conductor.
  • Ekip Dip LI electronic trip unit provides adjustable overload and instantaneous short-circuit protection.
  • 100 kA Icu at 380–440 V AC provides substantial short-circuit interruption capability.
  • 85 kA Icu at 500–690 V AC maintains high breaking performance at elevated system voltages.
  • Protection settings are configured using accessible DIP switches for straightforward commissioning.
  • 690 V AC rated operational voltage supports a broad range of industrial power systems.
  • Fixed construction with rear horizontal terminals is designed for integration into low-voltage switchboards.

Key Features

  • ABB SACE Emax 2 E2.2H frame.
  • 1600 A rated current.
  • Four-pole fixed air circuit breaker.
  • Ekip Dip LI electronic protection release.
  • Long-time overload protection (L).
  • Instantaneous short-circuit protection (I).
  • Overload protection adjustable from 0.4–1 × In.
  • Instantaneous protection adjustable from 1.5–15 × In.
  • DIP-switch protection setting interface.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 50 / 60 Hz rated frequency.
  • 100 kA Icu at 380–440 V AC.
  • 85 kA Icu at 500–690 V AC.
  • Rear horizontal main-terminal arrangement.
  • Designed for power-distribution protection.
  • Compliant with IEC 60947-2.

Reliable High-Fault-Level Distribution Protection

The ABB SACE Emax 2 E2.2H is engineered for critical switching and protection duties where high prospective short-circuit currents must be safely interrupted. Its 1600 A continuous-current capability and breaking performance reaching 100 kA make this configuration particularly suitable for main distribution circuits located close to transformers or other high-capacity power sources.

The Ekip Dip LI release combines long-time protection against sustained overload conditions with instantaneous protection against severe short circuits. Adjustable thresholds allow the protection characteristics to be matched to the circuit, while the DIP-switch interface provides a direct method of configuring the breaker during commissioning and maintenance.

Typical Applications

  • Main low-voltage switchboards and distribution assemblies.
  • Industrial main incomer protection.
  • Transformer secondary distribution systems.
  • High-current feeder circuits.
  • Manufacturing and process facilities.
  • Commercial and infrastructure electrical distribution.
  • High-fault-level industrial power networks.
  • AC distribution circuits requiring adjustable overload and instantaneous short-circuit protection.

Technical Specifications

Series SACE Emax 2
Frame E2.2H
ABB order code 1SDA071641R1
EAN 8015644754914
Product type Air circuit breaker
Current type AC
Rated current 1600 A
Number of poles 4
Trip unit Ekip Dip LI
Release type Electronic
Protection application Power distribution
Protection functions Long-time (L) and instantaneous (I)
Overload protection adjustment 0.4–1 × In
Instantaneous protection adjustment 1.5–15 × In
Protection setting method DIP switches
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated frequency 50 / 60 Hz
Icu at 380 V AC 100 kA
Icu at 400 / 415 V AC 100 kA
Icu at 440 V AC 100 kA
Icu at 500 / 525 V AC 85 kA
Icu at 690 V AC 85 kA
Installation Fixed
Terminal position Rear
Terminal orientation Horizontal
Net weight 53 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB E2.2H 1600 Ekip Dip LI 4p FHR used for?

It is a 1600 A four-pole fixed air circuit breaker designed for switching and protection of high-current low-voltage distribution circuits, particularly where substantial short-circuit breaking capacity is required.

What protection functions does the Ekip Dip LI trip unit provide?

The Ekip Dip LI electronic trip unit provides long-time overload protection and instantaneous short-circuit protection, with the protection thresholds configured using DIP switches.

What is the breaking capacity of ABB 1SDA071641R1?

The E2.2H 1600 provides an ultimate short-circuit breaking capacity of 100 kA at 380–440 V AC and 85 kA at 500–690 V AC.

What are the Ekip Dip LI protection adjustment ranges?

The long-time overload threshold is adjustable from 0.4–1 × In, while instantaneous short-circuit protection is adjustable from 1.5–15 × In.

Is ABB 1SDA071641R1 fixed or withdrawable?

This configuration is a fixed four-pole air circuit breaker with rear horizontal terminals for integration into low-voltage switchgear.

High-Performance Power Protection from ABB SACE Emax 2

ABB SACE Emax 2 air circuit breakers combine high short-circuit interruption capability, configurable electronic protection and robust switchboard integration to provide dependable protection for demanding low-voltage power distribution systems.