ABB 1SDA071633R1 E2.2S 1600 Ekip Dip LSIG four-pole fixed air circuit breaker with a 1600 A rated current, 85 kA breaking capacity at 440 V AC, LSIG electronic protection and rear horizontal terminals.
£7,454.79
The ABB E2.2S 1600 Ekip Dip LSIG 4p FHR, order code 1SDA071633R1, is a high-performance four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for protection and control of demanding low-voltage electrical distribution systems. Combining a 1600 A rated uninterrupted current with an Ekip Dip LSIG electronic trip unit, it provides comprehensive overload, selective short-circuit, instantaneous short-circuit and earth-fault protection for industrial, commercial and infrastructure power distribution applications.
This E2.2S circuit breaker is supplied in a fixed four-pole configuration with rear horizontal terminals. Its Ekip Dip LSIG solid-state electronic release provides long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection, with DIP-switch adjustment providing a straightforward method of configuring protection settings during commissioning and maintenance.
With a 1600 A rated uninterrupted current, an S short-circuit performance level and a rated ultimate short-circuit breaking capacity of 85 kA at 440 V AC, the 1SDA071633R1 is engineered for substantial power distribution duties. The E2.2S platform also provides a rated short-time withstand current of 66 kA for 1 second, supporting robust fault protection and selective coordination in high-current low-voltage switchboards.
Air circuit breakers such as the ABB SACE Emax 2 E2.2S provide switching, isolation and protection for high-current low-voltage distribution circuits. They are commonly installed as incoming, outgoing or bus-coupler breakers in electrical switchboards, where dependable interruption of overload, short-circuit and earth-fault currents is essential for protecting equipment and maintaining continuity of supply.
The Ekip Dip LSIG electronic trip unit combines configurable electronic protection with straightforward DIP-switch adjustment. Its long-time, selective short-circuit, instantaneous and earth-fault functions enable the breaker to respond appropriately to a broad range of electrical fault conditions, while the high breaking and short-time withstand capabilities of the E2.2S platform support effective protection coordination in demanding electrical networks.
| Series | SACE Emax 2 |
|---|---|
| Frame / product group | E2.2S |
| ABB order code | 1SDA071633R1 |
| EAN | 8015644754839 |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 1600 A |
| Number of poles | 4 |
| Trip unit | Ekip Dip LSIG |
| Release type | Solid-state electronic |
| Protection functions | LSIG – long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection |
| Overload protection adjustment | 0.4–1 × In |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 85 kA |
| Rated short-time withstand current (Icw, 1 s) | 66 kA |
| Short-circuit performance level | S |
| Installation | Fixed |
| Terminal arrangement | Rear horizontal |
| Auxiliary contacts | 4 |
| Circuit-breaker position indication | Open / closed |
| Integrated earth-fault protection | Yes |
| Protection setting method | DIP switches |
| Weight | 53 kg |
| Applicable standard | IEC 60947-2 |
The ABB 1SDA071633R1 is a 1600 A four-pole air circuit breaker designed to protect and control high-current low-voltage power distribution circuits in industrial, commercial and infrastructure installations.
The E2.2S 1600 supplied under ABB order code 1SDA071633R1 has a rated uninterrupted current of 1600 A.
The circuit breaker is fitted with an Ekip Dip LSIG electronic trip unit, providing long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection.
The E2.2S 1600 has a rated ultimate short-circuit breaking capacity of 85 kA at 440 V AC and a rated short-time withstand current of 66 kA for 1 second.
The 1SDA071633R1 is a fixed air circuit breaker with four poles and rear horizontal terminals, intended for permanent installation within compatible low-voltage switchgear and distribution assemblies.
ABB SACE Emax 2 air circuit breakers combine high fault-interruption performance with dependable electronic protection, making the E2.2S range a robust choice for demanding low-voltage distribution systems in industrial, commercial and infrastructure applications.