1SDA071630R1 ABB E2.2N 1600 Ekip G Hi-Touch LSIG 4p FHR Air Circuit Breaker

1SDA071630R1 ABB E2.2N 1600 Ekip G Hi-Touch LSIG 4p FHR Air Circuit Breaker

ABB 1SDA071630R1 Emax 2 E2.2N 1600 A four-pole fixed air circuit breaker with rear flat horizontal terminals, Ekip G Hi-Touch LSIG electronic protection and 66 kA breaking capacity at 400 V AC for generator and low-voltage power distribution systems.

SKU: 1SDA071630R1MPN: 1SDA071630R1
Price
List Price £13,389.37 ex VAT
Your Price (ex VAT) Save 25%
£10,042.03 25% OFF
You save £3,347.34 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £10,042.03
Trade pricing is personalised to your account

Manufacturer Lead Time

£10,042.03

Why Choose the ABB E2.2N 1600 Ekip G Hi-Touch LSIG 4p FHR Air Circuit Breaker?

The ABB E2.2N 1600 Ekip G Hi-Touch LSIG 4p FHR, order code 1SDA071630R1, is a high-performance four-pole air circuit breaker (ACB) designed for generator protection and demanding low-voltage power distribution systems. Part of the ABB SACE Emax 2 series, it combines a 1600 A rated uninterrupted current, a 690 V AC rated voltage and advanced electronic protection for industrial, commercial, infrastructure and power-generation applications.

The breaker is equipped with the Ekip G Hi-Touch LSIG electronic trip unit, combining generator-oriented protection capabilities with long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection. The Hi-Touch platform provides advanced protection, measurement and monitoring functionality for installations requiring greater control and visibility than conventional circuit-breaker protection.

The E2.2N frame provides an ultimate short-circuit breaking capacity of 66 kA at 400 V AC. Its fixed four-pole construction uses rear flat horizontal terminals and bolt-connected main circuits, making the 1SDA071630R1 suitable for permanent integration into generator switchboards, main distribution panels and low-voltage busbar systems.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker for generator and low-voltage distribution protection.
  • 1600 A rated uninterrupted current for substantial industrial and infrastructure loads.
  • Four-pole configuration for switching and protection of three-phase systems with neutral.
  • Ekip G Hi-Touch LSIG electronic trip unit combines generator-oriented functionality with comprehensive electrical protection.
  • Long-time, short-time, instantaneous and earth-fault protection in a single electronic release.
  • 66 kA ultimate breaking capacity at 400 V AC for demanding fault-current conditions.
  • Advanced Hi-Touch platform supports protection, measurement and monitoring of critical electrical systems.
  • Fixed construction with rear flat horizontal terminals for efficient switchboard and busbar integration.

Key Features

  • ABB SACE Emax 2 E2.2N series.
  • 1600 A rated uninterrupted current.
  • Four-pole air circuit breaker.
  • Fixed mounting configuration.
  • Rear flat horizontal terminals.
  • Ekip G Hi-Touch LSIG solid-state electronic release.
  • Long-time overload protection.
  • Short-time selective short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • Generator-oriented electronic protection platform.
  • Advanced measurement and monitoring capabilities.
  • 690 V AC rated voltage.
  • 66 kA Icu at 400 V AC.
  • Four change-over auxiliary contacts.
  • Optional motor drive capability.

Advanced Generator and Power Distribution Protection

Generator and main distribution circuit breakers must provide dependable fault interruption while supporting appropriate coordination throughout the electrical installation. The ABB SACE Emax 2 platform combines robust air circuit-breaker construction with advanced electronic protection, measurement and monitoring technology for critical low-voltage electrical systems.

The Ekip G Hi-Touch LSIG release combines generator-oriented functionality with long-time overload, short-time selective, instantaneous short-circuit and earth-fault protection. This comprehensive protection platform makes the 1SDA071630R1 particularly suitable for installations where generator protection, selective fault clearing, electrical monitoring and dependable high-current distribution protection are required.

Typical Applications

  • Generator protection and switching systems.
  • Generator main switchboards.
  • Main low-voltage electrical distribution switchboards.
  • Industrial power generation and distribution systems.
  • Commercial and infrastructure standby power systems.
  • Manufacturing and process plant electrical systems.
  • Systems requiring selective short-circuit and earth-fault protection.
  • OEM generator panels, low-voltage switchgear and busbar assemblies.

Technical Specifications

Product group Emax2 Air Circuit Breaker
Series SACE Emax 2 E2.2N
ABB order code 1SDA071630R1
EAN 8015644754808
Product type Air circuit breaker
Rated uninterrupted current (Iu) 1600 A
Rated voltage 690 V AC
Number of poles 4
Trip unit Ekip G Hi-Touch LSIG electronic release
Release technology Solid-state electronic
Protection functions L (long-time overload), S (short-time short circuit), I (instantaneous short circuit) and G (earth fault)
Integrated earth-fault protection Yes
Ultimate breaking capacity (Icu) at 400 V AC 66 kA
Installation Fixed
Terminal arrangement Rear flat horizontal
Main circuit connection Bolt connection
Connection position Rear
Auxiliary contacts 4 change-over contacts
Open/closed indication Yes
Control element Push button
Integrated motor drive No
Optional motor drive Yes
Degree of protection IP30
Dimensions 366 × 371 × 270 mm
Net weight 58 kg
Country of origin Italy
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071630R1 used for?

The ABB 1SDA071630R1 is a four-pole air circuit breaker designed for generator protection and high-current low-voltage power distribution applications requiring advanced electronic protection, monitoring and dependable fault interruption.

What is the rated current of the ABB E2.2N 1600?

The ABB E2.2N 1600 has a rated uninterrupted current of 1600 A, making it suitable for substantial generator and low-voltage distribution circuits.

What protection does the Ekip G Hi-Touch LSIG trip unit provide?

The Ekip G Hi-Touch LSIG electronic trip unit provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection together with advanced generator-oriented protection, measurement and monitoring capabilities.

What is the breaking capacity of the ABB 1SDA071630R1?

The ABB E2.2N 1600 has an ultimate short-circuit breaking capacity of 66 kA at 400 V AC, providing robust fault-current interruption for demanding generator and distribution applications.

What does FHR mean on the ABB E2.2N 1600?

The FHR configuration identifies this Emax 2 breaker as a fixed version with rear flat horizontal terminals, designed for permanent integration into compatible generator panels, low-voltage switchboards and busbar systems.

Trusted Generator and Power Distribution Technology from ABB

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, measurement and monitoring with robust short-circuit performance, providing a versatile platform for generator protection and demanding low-voltage electrical distribution systems.