1SDA071618R1 ABB E2.2B 1600 Ekip Hi-Touch LSI 4p F HR Air Circuit Breaker 1600 A

1SDA071618R1 ABB E2.2B 1600 Ekip Hi-Touch LSI 4p F HR Air Circuit Breaker 1600 A

ABB 1SDA071618R1 E2.2B 1600 Ekip Hi-Touch LSI 4p F HR is a 1600 A four-pole fixed SACE Emax 2 air circuit breaker with advanced Ekip Hi-Touch LSI electronic protection, 42 kA short-circuit breaking capacity and rear horizontal terminals.

SKU: 1SDA071618R1MPN: 1SDA071618R1
Price
List Price £11,537.89 ex VAT
Your Price (ex VAT) Save 25%
£8,653.42 25% OFF
You save £2,884.47 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,653.42
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,653.42

Why Choose the ABB E2.2B 1600 Ekip Hi-Touch LSI 4p F HR Air Circuit Breaker?

The ABB E2.2B 1600 Ekip Hi-Touch LSI 4p F HR, order code 1SDA071618R1, is a high-performance four-pole air circuit breaker (ACB) designed for protection, switching and control in low-voltage electrical distribution systems. As part of the advanced ABB SACE Emax 2 series, it combines a 1600 A rated current with the sophisticated Ekip Hi-Touch LSI electronic trip unit for precise protection and advanced monitoring of demanding electrical installations.

The Ekip Hi-Touch LSI release provides long-time overload, selective short-time and instantaneous short-circuit protection. Its advanced touchscreen interface supports detailed configuration and monitoring, making the breaker well suited to installations requiring accurate protection coordination and comprehensive electrical system supervision.

With a four-pole configuration, fixed construction and rear horizontal terminals, the E2.2B 1600 is designed for straightforward integration into low-voltage switchboards. The E2.2B performance level provides a rated ultimate short-circuit breaking capacity of 42 kA at 415–440 V AC, together with a 42 kA short-time withstand current, providing dependable protection for industrial and commercial power distribution.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker for low-voltage power distribution.
  • 1600 A rated current for substantial industrial and commercial electrical loads.
  • Four-pole configuration for switching and protection of three phases and neutral.
  • Advanced Ekip Hi-Touch LSI electronic trip unit with touchscreen interface.
  • Provides long-time, short-time and instantaneous short-circuit protection.
  • 42 kA short-circuit breaking capacity at 415–440 V AC.
  • Adjustable protection settings support effective selectivity and coordination within the electrical installation.
  • Fixed construction with rear horizontal terminals for switchboard installation.

Key Features

  • ABB SACE Emax 2 E2.2B series.
  • 1600 A rated current.
  • Four-pole fixed air circuit breaker.
  • Ekip Hi-Touch LSI electronic trip unit.
  • Long-time overload protection.
  • Selective short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • 42 kA Icu at 415–440 V AC.
  • 42 kA rated short-time withstand current (Icw) for 1 s.
  • Adjustable long-time protection range from 640–1600 A.
  • Adjustable instantaneous threshold from 2400–24000 A.
  • Rear horizontal main terminals for fixed switchboard installation.
  • Advanced Ekip Hi-Touch interface for protection configuration and electrical system monitoring.

Advanced Protection for Low-Voltage Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 provide switching, isolation and protection for high-current low-voltage distribution circuits. The E2.2B 1600 is designed for circuits carrying up to 1600 A and provides short-circuit interruption and withstand performance of 42 kA, helping protect switchboards, cables, transformers and connected electrical equipment against damaging fault conditions.

The Ekip Hi-Touch LSI electronic release combines long-time overload protection with selective short-time and instantaneous short-circuit protection. The advanced Ekip platform enables precise protection configuration and supports the monitoring and integration requirements of modern industrial and commercial electrical distribution systems.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial electrical distribution systems.
  • Commercial building power distribution.
  • Manufacturing and process plants.
  • Transformer and distribution feeder protection.
  • Infrastructure and utility installations.
  • Power distribution centres and switchgear assemblies.
  • Electrical systems requiring advanced protection coordination and monitoring.

Technical Specifications

Series SACE Emax 2
Frame / type E2.2B
Order code 1SDA071618R1
Product type Air circuit breaker
Rated current (In) 1600 A
Number of poles 4
Release Ekip Hi-Touch LSI
Release type Electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Long-time protection adjustment 640–1600 A
Instantaneous protection threshold 2400–24000 A
Rated ultimate short-circuit breaking capacity (Icu) at 415–440 V AC 42 kA
Rated short-time withstand current (Icw) 42 kA for 1 s
Short-circuit performance level B
Version Fixed (F)
Terminal connection Rear horizontal (HR)
Installation Fixed switchboard mounting
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071618R1 used for?

The ABB 1SDA071618R1 is a 1600 A four-pole air circuit breaker used for switching and protecting low-voltage power distribution circuits in industrial, commercial and infrastructure installations.

What is the current rating of the E2.2B 1600 Ekip Hi-Touch LSI?

The circuit breaker has a rated current of 1600 A, with a long-time protection adjustment range of 640–1600 A.

What protection does the Ekip Hi-Touch LSI release provide?

The Ekip Hi-Touch LSI electronic trip unit provides long-time overload, selective short-time short-circuit and instantaneous short-circuit protection.

What is the breaking capacity of the ABB E2.2B 1600?

The E2.2B 1600 provides a rated ultimate short-circuit breaking capacity of 42 kA at 415–440 V AC and a rated short-time withstand current of 42 kA for 1 s.

Is the ABB 1SDA071618R1 fixed or withdrawable?

The 1SDA071618R1 is a fixed four-pole air circuit breaker with rear horizontal terminals for installation within a low-voltage switchboard.

Trusted Advanced Power Protection from ABB

ABB SACE Emax 2 air circuit breakers combine dependable short-circuit performance with advanced electronic protection, monitoring and system integration capabilities for modern low-voltage electrical distribution systems.