Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA071616R1 E2.2B 1600 Ekip Touch LSIG four-pole fixed air circuit breaker with a 1600 A rated current, 42 kA breaking capacity at 400/415 V AC, LSIG electronic protection and rear horizontal flat terminals.
£6,504.65
The ABB E2.2B 1600 Ekip Touch LSIG 4p FHR, order code 1SDA071616R1, is a high-performance four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for protection and control of low-voltage electrical distribution systems. Combining a 1600 A rated uninterrupted current with the advanced Ekip Touch LSIG electronic trip unit, it provides comprehensive overload, selective short-circuit, instantaneous short-circuit and earth-fault protection for industrial, commercial and infrastructure power distribution applications.
This E2.2B circuit breaker is supplied in a fixed four-pole configuration with rear horizontal flat terminals. Its Ekip Touch LSIG electronic release combines configurable protection functions with an intuitive touch interface, helping operators commission, monitor and manage protection settings while providing comprehensive LSIG protection for the connected distribution circuit.
With a 1600 A rated uninterrupted current and a rated ultimate short-circuit breaking capacity of 42 kA at 400/415 V AC, the 1SDA071616R1 is engineered for substantial low-voltage distribution duties. Its rated operational voltage extends to 690 V AC, with a 42 kA ultimate breaking capacity at 690 V AC and a rated short-time withstand current of 42 kA for 1 second.
Air circuit breakers such as the ABB SACE Emax 2 E2.2B provide switching, isolation and protection for high-current low-voltage distribution circuits. They are commonly installed as incoming, outgoing or bus-coupler breakers in electrical switchboards, where dependable interruption of overload, short-circuit and earth-fault currents is essential for protecting equipment and maintaining continuity of supply.
The Ekip Touch LSIG electronic trip unit provides configurable long-time, short-time, instantaneous and earth-fault protection functions through an advanced electronic interface. This comprehensive protection package enables the breaker to respond to sustained overloads, different levels of short-circuit current and earth faults, supporting effective protection coordination throughout modern low-voltage electrical networks.
| Series | SACE Emax 2 |
|---|---|
| Frame / product group | E2.2B |
| ABB order code | 1SDA071616R1 |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 1600 A |
| Rated current (In) | 1600 A |
| Number of poles | 4 |
| Neutral pole current | 100% of Iu |
| Trip unit | Ekip Touch LSIG |
| Release type | Electronic |
| Protection functions | LSIG – long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 42 kA |
| Rated service short-circuit breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw, 1 s) | 42 kA |
| Rated short-time withstand current (Icw, 3 s) | 42 kA |
| Short-circuit performance level | B |
| Installation | Fixed |
| Terminal arrangement | Rear horizontal flat |
| Terminal type | Bolted |
| Integrated earth-fault protection | Yes |
| Suitable for IT networks | Yes, up to 690 V |
| Power loss | 136 W |
| Mechanical durability | 25,000 cycles |
| Applicable standard | IEC 60947-2 |
The ABB 1SDA071616R1 is a 1600 A four-pole air circuit breaker designed to protect and control high-current low-voltage power distribution circuits in industrial, commercial and infrastructure installations.
The E2.2B 1600 supplied under ABB order code 1SDA071616R1 has a rated uninterrupted current of 1600 A.
The circuit breaker is fitted with an Ekip Touch LSIG electronic trip unit, providing long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection.
The E2.2B 1600 has a rated ultimate short-circuit breaking capacity of 42 kA at 400/415 V AC, with the 42 kA rating maintained at operating voltages up to 690 V AC.
The 1SDA071616R1 is a fixed air circuit breaker with four poles and rear horizontal flat terminals, intended for permanent installation within compatible low-voltage switchgear and distribution assemblies.
ABB SACE Emax 2 air circuit breakers combine robust electrical performance with advanced electronic protection technology, making them a dependable choice for sophisticated low-voltage distribution systems in industrial, commercial and infrastructure applications.
We use cookies