1SDA071611R1 ABB E2.2B 1600 Ekip Dip LI 4-Pole Fixed Air Circuit Breaker

1SDA071611R1 ABB E2.2B 1600 Ekip Dip LI 4-Pole Fixed Air Circuit Breaker

ABB 1SDA071611R1 Emax 2 E2.2B 1600 is a 1600 A four-pole fixed air circuit breaker with rear horizontal terminals and an Ekip Dip LI solid-state electronic trip unit for long-time overload and instantaneous short-circuit protection.

SKU: 1SDA071611R1MPN: 1SDA071611R1
Price
List Price £7,522.99 ex VAT
Your Price (ex VAT) Save 25%
£5,642.24 25% OFF
You save £1,880.75 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,642.24
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,642.24

Why Choose the ABB E2.2B 1600 Ekip Dip LI 4p FHR Air Circuit Breaker?

The ABB E2.2B 1600 Ekip Dip LI 4p FHR, order code 1SDA071611R1, is a SACE Emax 2 air circuit breaker (ACB) designed for switching and protection in low-voltage AC power distribution systems. This fixed four-pole E2.2B breaker combines a 1600 A rated current with ABB's Ekip Dip LI solid-state electronic trip unit and rear horizontal main terminals.

The Ekip Dip LI release provides long-time overload (L) and instantaneous short-circuit (I) protection. This straightforward electronic protection configuration is well suited to installations requiring dependable overload and high-level short-circuit protection without the additional short-time or ground-fault functions provided by LSI and LSIG releases.

The E2.2B performance level provides an ultimate short-circuit breaking capacity of 42 kA at 440 V AC, together with a rated short-time withstand current of 42 kA for 1 s. ABB documentation also specifies 42 kA Icu at 690 V AC for this E2.2B configuration, making the 1SDA071611R1 a robust solution for industrial and commercial distribution boards operating at voltages up to 690 V AC.

Key Advantages

  • 1600 A rated current for high-current low-voltage distribution circuits.
  • Four-pole configuration for three-phase systems incorporating the neutral conductor.
  • Ekip Dip LI electronic trip unit provides long-time overload and instantaneous short-circuit protection.
  • 42 kA Icu at 440 V AC provides dependable interruption of high fault currents.
  • 42 kA Icw for 1 s supports robust performance under short-time fault conditions.
  • Rated for low-voltage AC systems up to 690 V AC.
  • Fixed construction with rear horizontal terminals for straightforward switchboard integration.
  • Supplied with four auxiliary contacts and circuit-breaker open/closed position indication.

Key Features

  • ABB SACE Emax 2 E2.2B frame.
  • 1600 A rated current.
  • Four-pole fixed air circuit breaker.
  • Ekip Dip LI solid-state electronic release.
  • Long-time overload protection (L).
  • Instantaneous short-circuit protection (I).
  • 42 kA ultimate breaking capacity at 440 V AC.
  • 42 kA ultimate breaking capacity at 690 V AC.
  • 42 kA short-time withstand current for 1 s.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Rear horizontal main terminals.
  • Four auxiliary contacts.
  • Circuit-breaker open/closed position indication.
  • 100% neutral-pole current rating.
  • Designed for AC power-distribution applications.

Reliable Protection for High-Current Distribution

The ABB SACE Emax 2 E2.2B is engineered for critical switching and protection duties within low-voltage distribution systems. Its 1600 A current rating and 42 kA short-circuit performance make this version suitable for main distribution circuits where dependable fault interruption, mechanical endurance and high continuous-current capability are required.

The Ekip Dip LI release combines long-time protection against sustained overload conditions with instantaneous protection for severe short circuits. Its electronic protection architecture provides repeatable operation while maintaining a comparatively straightforward protection scheme, making this breaker a practical choice for applications where LI protection is appropriate.

Typical Applications

  • Main low-voltage switchboards and distribution assemblies.
  • Industrial main incomers and feeder circuits.
  • Transformer secondary distribution systems.
  • Manufacturing and process plants.
  • Commercial building power distribution.
  • Infrastructure electrical systems.
  • High-current machinery and plant distribution boards.
  • AC networks requiring overload and instantaneous short-circuit protection.

Technical Specifications

Series SACE Emax 2
Frame E2.2B
ABB order code 1SDA071611R1
EAN 8015644754617
Product type Air circuit breaker
Current type AC
Rated current (In) 1600 A
Number of poles 4
Neutral pole current 100% of Iu
Trip unit Ekip Dip LI
Release type Solid-state electronic
Protection functions Long-time (L) and instantaneous (I)
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 42 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 42 kA
Rated short-time withstand current (Icw), 1 s 42 kA
Installation Fixed
Terminal position Rear
Terminal orientation Horizontal
Auxiliary contacts 4
Breaker position indication Open / closed
Power loss 136 W
Electrical durability at Ue ≤ 440 V 12,000 cycles
Electrical durability at 500–690 V 10,000 cycles
Mechanical durability 25,000 cycles
Product dimensions (W × H × D) 366 × 371 × 270 mm
Net weight 53 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB E2.2B 1600 Ekip Dip LI 4p FHR used for?

It is a 1600 A four-pole fixed air circuit breaker designed for switching and protection of high-current low-voltage AC distribution circuits in industrial, commercial and infrastructure installations.

What protection functions does the Ekip Dip LI trip unit provide?

The Ekip Dip LI solid-state electronic release provides long-time overload protection (L) and instantaneous short-circuit protection (I).

What is the breaking capacity of ABB 1SDA071611R1?

The E2.2B 1600 has an ultimate short-circuit breaking capacity of 42 kA at 440 V AC; ABB documentation also specifies 42 kA at 690 V AC for the E2.2B configuration.

Is ABB 1SDA071611R1 fixed or withdrawable?

This configuration is a fixed four-pole air circuit breaker supplied with rear horizontal terminals for integration into low-voltage switchgear.

What accessories are fitted to the ABB 1SDA071611R1?

ABB specifies this breaker as fitted with four auxiliary contacts and circuit-breaker open/closed position indication.

Dependable Power Protection from ABB SACE Emax 2

ABB SACE Emax 2 air circuit breakers combine electronic protection, high-current switching capability and robust mechanical construction to provide dependable protection for modern low-voltage power distribution systems.