1SDA071600R1 ABB E2.2S 1250 Ekip G Hi-Touch LSIG 4p FHR Air Circuit Breaker

1SDA071600R1 ABB E2.2S 1250 Ekip G Hi-Touch LSIG 4p FHR Air Circuit Breaker

ABB 1SDA071600R1 E2.2S 1250 Ekip G Hi-Touch LSIG four-pole fixed air circuit breaker with a 1250 A rated current, 85 kA breaking capacity at 400/415 V AC, LSIG generator protection and rear horizontal flat terminals.

SKU: 1SDA071600R1MPN: 1SDA071600R1
Price
List Price £13,506.30 ex VAT
Your Price (ex VAT) Save 25%
£10,129.73 25% OFF
You save £3,376.58 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £10,129.73
Trade pricing is personalised to your account

Manufacturer Lead Time

£10,129.73

Why Choose the ABB E2.2S 1250 Ekip G Hi-Touch LSIG 4p FHR Air Circuit Breaker?

The ABB E2.2S 1250 Ekip G Hi-Touch LSIG 4p FHR, order code 1SDA071600R1, is a high-performance four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for generator protection and demanding low-voltage electrical distribution systems. Combining a 1250 A rated uninterrupted current with the advanced Ekip G Hi-Touch LSIG electronic trip unit, it provides comprehensive overload, short-circuit and earth-fault protection together with advanced protection functionality for generator applications.

This E2.2S circuit breaker is supplied in a fixed four-pole configuration with rear horizontal flat terminals. Its Ekip G Hi-Touch LSIG solid-state electronic release provides long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection. The generator-focused Ekip G platform makes the breaker particularly suitable for installations where reliable protection of generators and associated distribution equipment is required.

With a 1250 A rated uninterrupted current, an S performance level and a rated ultimate short-circuit breaking capacity of 85 kA at 400/415 V AC, the 1SDA071600R1 is engineered for substantial power distribution duties. It operates at rated voltages up to 690 V AC, provides a 66 kA short-time withstand current for 1 second and maintains a 66 kA ultimate breaking capacity at 690 V AC.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for generator and low-voltage power distribution applications.
  • 1250 A rated uninterrupted current for demanding industrial and commercial electrical systems.
  • Four-pole configuration with a neutral pole rated at 100% of uninterrupted current.
  • Advanced Ekip G Hi-Touch LSIG electronic trip unit with overload, short-circuit and earth-fault protection.
  • 85 kA ultimate breaking capacity at 400/415 V AC for high fault-level installations.
  • 66 kA short-time withstand current for 1 second supports selective protection strategies.
  • Suitable for IT networks up to 690 V.
  • Fixed installation with rear horizontal flat terminals for switchboard integration.

Key Features

  • ABB SACE Emax 2 E2.2S series.
  • 1250 A rated uninterrupted current.
  • Four-pole air circuit breaker.
  • Ekip G Hi-Touch LSIG solid-state electronic protection release.
  • Long-time overload protection (L).
  • Selective short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Integrated earth-fault protection (G).
  • 85 kA ultimate breaking capacity at 400/415 V AC.
  • 66 kA ultimate breaking capacity at 690 V AC.
  • 66 kA rated short-time withstand current for 1 second.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Fixed mounting configuration with rear horizontal flat terminals.
  • Fitted with four auxiliary changeover contacts and circuit-breaker open/closed position indication.

Advanced Generator and Power Distribution Protection

Air circuit breakers such as the ABB SACE Emax 2 E2.2S provide switching, isolation and protection for high-current low-voltage circuits. They are commonly installed in generator switchboards, main distribution assemblies, incoming feeders and bus-coupler applications where dependable interruption of overload, short-circuit and earth-fault currents is essential for equipment protection and continuity of supply.

The Ekip G Hi-Touch LSIG electronic trip unit combines advanced generator-oriented functionality with configurable long-time, short-time, instantaneous and earth-fault protection. Together with the high breaking capacity of the E2.2S platform, this enables the breaker to protect generators and associated distribution circuits while supporting effective coordination and selective operation within complex electrical networks.

Typical Applications

  • Generator protection and generator switchboards.
  • Low-voltage main distribution switchboards.
  • Industrial power generation and distribution systems.
  • Incoming and outgoing feeder protection.
  • Bus-coupler and distribution circuit applications.
  • Critical power and standby generation systems.
  • Data centres and infrastructure power systems.
  • Industrial installations with high prospective short-circuit currents.

Technical Specifications

Series SACE Emax 2
Frame / product group E2.2S
ABB order code 1SDA071600R1
Product type Air circuit breaker
Rated uninterrupted current (Iu) 1250 A
Rated current (In) 1250 A
Number of poles 4
Neutral pole current 100% of Iu
Trip unit Ekip G Hi-Touch LSIG
Release type Electronic
Protection functions LSIG – long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw, 1 s) 66 kA
Rated short-time withstand current (Icw, 3 s) 50 kA
Installation Fixed
Terminal arrangement Rear horizontal flat
Main circuit connection Bolted
Auxiliary contacts 4 changeover contacts
Integrated earth-fault protection Yes
Suitable for IT networks Yes, up to 690 V
Power loss 83 W
Applicable standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071600R1 used for?

The ABB 1SDA071600R1 is a 1250 A four-pole air circuit breaker designed for generator protection and high-current low-voltage power distribution applications.

What is the rated current of the ABB E2.2S 1250?

The E2.2S 1250 supplied under ABB order code 1SDA071600R1 has a rated uninterrupted current of 1250 A.

What protection unit is fitted to the 1SDA071600R1?

The circuit breaker is fitted with an Ekip G Hi-Touch LSIG electronic trip unit, providing long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection together with functionality intended for generator applications.

What is the breaking capacity of the ABB E2.2S 1250?

The E2.2S 1250 has a rated ultimate short-circuit breaking capacity of 85 kA at 400/415 V AC and 66 kA at 690 V AC.

Is the ABB 1SDA071600R1 fixed or withdrawable?

The 1SDA071600R1 is a fixed air circuit breaker with four poles and rear horizontal flat terminals, intended for permanent installation within compatible low-voltage switchgear and generator distribution assemblies.

Trusted ABB Protection for Generator and Critical Power Systems

ABB SACE Emax 2 air circuit breakers combine high fault-interruption performance with advanced electronic protection, making the E2.2S with Ekip G Hi-Touch a robust choice for generator protection and demanding low-voltage distribution systems.