ABB 1SDA071600R1 E2.2S 1250 Ekip G Hi-Touch LSIG four-pole fixed air circuit breaker with a 1250 A rated current, 85 kA breaking capacity at 400/415 V AC, LSIG generator protection and rear horizontal flat terminals.
£10,129.73
The ABB E2.2S 1250 Ekip G Hi-Touch LSIG 4p FHR, order code 1SDA071600R1, is a high-performance four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for generator protection and demanding low-voltage electrical distribution systems. Combining a 1250 A rated uninterrupted current with the advanced Ekip G Hi-Touch LSIG electronic trip unit, it provides comprehensive overload, short-circuit and earth-fault protection together with advanced protection functionality for generator applications.
This E2.2S circuit breaker is supplied in a fixed four-pole configuration with rear horizontal flat terminals. Its Ekip G Hi-Touch LSIG solid-state electronic release provides long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection. The generator-focused Ekip G platform makes the breaker particularly suitable for installations where reliable protection of generators and associated distribution equipment is required.
With a 1250 A rated uninterrupted current, an S performance level and a rated ultimate short-circuit breaking capacity of 85 kA at 400/415 V AC, the 1SDA071600R1 is engineered for substantial power distribution duties. It operates at rated voltages up to 690 V AC, provides a 66 kA short-time withstand current for 1 second and maintains a 66 kA ultimate breaking capacity at 690 V AC.
Air circuit breakers such as the ABB SACE Emax 2 E2.2S provide switching, isolation and protection for high-current low-voltage circuits. They are commonly installed in generator switchboards, main distribution assemblies, incoming feeders and bus-coupler applications where dependable interruption of overload, short-circuit and earth-fault currents is essential for equipment protection and continuity of supply.
The Ekip G Hi-Touch LSIG electronic trip unit combines advanced generator-oriented functionality with configurable long-time, short-time, instantaneous and earth-fault protection. Together with the high breaking capacity of the E2.2S platform, this enables the breaker to protect generators and associated distribution circuits while supporting effective coordination and selective operation within complex electrical networks.
| Series | SACE Emax 2 |
|---|---|
| Frame / product group | E2.2S |
| ABB order code | 1SDA071600R1 |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 1250 A |
| Rated current (In) | 1250 A |
| Number of poles | 4 |
| Neutral pole current | 100% of Iu |
| Trip unit | Ekip G Hi-Touch LSIG |
| Release type | Electronic |
| Protection functions | LSIG – long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC | 85 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC | 85 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 85 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC | 66 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 66 kA |
| Rated service short-circuit breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw, 1 s) | 66 kA |
| Rated short-time withstand current (Icw, 3 s) | 50 kA |
| Installation | Fixed |
| Terminal arrangement | Rear horizontal flat |
| Main circuit connection | Bolted |
| Auxiliary contacts | 4 changeover contacts |
| Integrated earth-fault protection | Yes |
| Suitable for IT networks | Yes, up to 690 V |
| Power loss | 83 W |
| Applicable standard | IEC 60947-2 |
The ABB 1SDA071600R1 is a 1250 A four-pole air circuit breaker designed for generator protection and high-current low-voltage power distribution applications.
The E2.2S 1250 supplied under ABB order code 1SDA071600R1 has a rated uninterrupted current of 1250 A.
The circuit breaker is fitted with an Ekip G Hi-Touch LSIG electronic trip unit, providing long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection together with functionality intended for generator applications.
The E2.2S 1250 has a rated ultimate short-circuit breaking capacity of 85 kA at 400/415 V AC and 66 kA at 690 V AC.