1SDA071578R1 ABB E2.2H 1000 Ekip Hi-Touch LSI 4-Pole Fixed Air Circuit Breaker

1SDA071578R1 ABB E2.2H 1000 Ekip Hi-Touch LSI 4-Pole Fixed Air Circuit Breaker

ABB 1SDA071578R1 Emax 2 E2.2H 1000 is a 1000 A four-pole fixed air circuit breaker with rear horizontal terminals and an Ekip Hi-Touch LSI electronic trip unit providing advanced overload, short-circuit, measurement and network analysis functions.

SKU: 1SDA071578R1MPN: 1SDA071578R1
Price
List Price £12,765.73 ex VAT
Your Price (ex VAT) Save 25%
£9,574.30 25% OFF
You save £3,191.43 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,574.30
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,574.30

Why Choose the ABB E2.2H 1000 Ekip Hi-Touch LSI 4p FHR Air Circuit Breaker?

The ABB E2.2H 1000 Ekip Hi-Touch LSI 4p FHR, order code 1SDA071578R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for advanced protection, measurement and switching in demanding low-voltage power distribution systems. Part of the ABB Emax 2 E2.2 series, this fixed four-pole circuit breaker combines a 1000 A rated current with the sophisticated Ekip Hi-Touch LSI electronic trip unit.

The Ekip Hi-Touch LSI release provides long-time overload, short-time selective short-circuit and instantaneous short-circuit protection together with advanced measurement capabilities. Integrated Ekip Measuring Pro functionality and network analysis capabilities make this version particularly suitable for installations where detailed electrical information, power-quality supervision and configurable circuit protection are required.

The E2.2H performance level provides an ultimate short-circuit breaking capacity of 100 kA at 380–440 V AC and 85 kA at 500–690 V AC. With a rated operational voltage of 690 V AC, fixed construction and rear horizontal terminals, the 1SDA071578R1 provides a robust solution for main incomers, feeders and critical high-current distribution circuits.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker for demanding low-voltage power distribution.
  • 1000 A rated current for high-current industrial and infrastructure circuits.
  • Four-pole configuration for three-phase systems incorporating the neutral conductor.
  • Ekip Hi-Touch LSI electronic trip unit combines advanced protection, measurement and monitoring.
  • Long-time, short-time and instantaneous protection functions support selective system coordination.
  • 100 kA Icu at 380–440 V AC for installations with high prospective fault currents.
  • 85 kA Icu at 500–690 V AC provides strong breaking performance at higher operating voltages.
  • Integrated Ekip Measuring Pro and Network Analyzer capabilities for enhanced electrical monitoring.
  • Fixed construction with rear horizontal terminals for switchboard integration.

Key Features

  • ABB SACE Emax 2 E2.2H frame.
  • 1000 A rated current.
  • Four-pole fixed air circuit breaker.
  • Ekip Hi-Touch LSI solid-state electronic release.
  • Long-time overload protection (L).
  • Short-time selective short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Overload protection adjustable from 0.4–1 × In.
  • Instantaneous protection adjustable from 1.5–15 × In.
  • Ekip Measuring Pro integrated measurement functionality.
  • Integrated Network Analyzer functionality.
  • Touch-sensitive display interface for configuration and monitoring.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 50 / 60 Hz operating frequency.
  • 100 kA Icu at 380–440 V AC.
  • 85 kA Icu at 500–690 V AC.
  • Rear horizontal main terminals.
  • Four auxiliary contacts with breaker open/closed position indication.
  • Designed in accordance with IEC 60947-2.

Advanced Protection and Power Monitoring

Air circuit breakers such as the ABB Emax 2 E2.2H provide critical switching and protection at key points in low-voltage distribution networks. The high breaking performance of the E2.2H frame makes this model particularly suitable for transformer-fed switchboards and industrial systems where prospective short-circuit currents can be substantial.

The Ekip Hi-Touch LSI release extends conventional circuit protection with advanced measurement and network analysis capabilities. Long-time protection responds to sustained overloads, short-time protection supports selective coordination with downstream devices, and instantaneous protection rapidly interrupts severe short circuits. Integrated measurement and analysis functions also provide valuable electrical information for system supervision, energy management and preventative maintenance.

Typical Applications

  • Main low-voltage switchboards and power-distribution assemblies.
  • Industrial main incomer and feeder protection.
  • Transformer secondary distribution systems.
  • Manufacturing and process facilities.
  • Data centres and critical power infrastructure.
  • Commercial and large-building electrical distribution.
  • Utility and infrastructure installations.
  • Power systems requiring advanced electrical measurement and network analysis.

Technical Specifications

Series SACE Emax 2
Frame E2.2H
ABB order code 1SDA071578R1
EAN 8015644754280
Product type Air circuit breaker
Rated current 1000 A
Number of poles 4
Trip unit Ekip Hi-Touch LSI
Release type Solid-state electronic
Protection functions Long-time (L), short-time (S) and instantaneous (I)
Overload protection setting 0.4–1 × In
Instantaneous protection setting 1.5–15 × In
Integrated measurement Ekip Measuring Pro
Network analysis Integrated Network Analyzer
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50 / 60 Hz
Icu at 380 / 400 / 415 / 440 V AC 100 kA
Icu at 500 / 525 / 690 V AC 85 kA
Rated short-time withstand current (Icw), 1 s 85 kA
Installation Fixed
Terminal position Rear
Terminal orientation Horizontal
Main circuit connection Bolted connection
Auxiliary contacts 4
Open/closed position indication Yes
Integrated motor drive No
Optional motor drive Yes
Degree of protection IP30
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB E2.2H 1000 Ekip Hi-Touch LSI 4p FHR used for?

It is a 1000 A four-pole air circuit breaker designed for advanced protection, switching and electrical monitoring of high-current low-voltage distribution circuits.

What protection functions does the Ekip Hi-Touch LSI trip unit provide?

The Ekip Hi-Touch LSI electronic release provides long-time overload, short-time selective short-circuit and instantaneous short-circuit protection, together with advanced measurement and analysis functions.

What is the breaking capacity of ABB 1SDA071578R1?

The E2.2H 1000 provides an ultimate short-circuit breaking capacity of 100 kA at 380–440 V AC and 85 kA at 500–690 V AC.

Does the Ekip Hi-Touch LSI provide electrical measurement functions?

Yes. This configuration incorporates Ekip Measuring Pro and Network Analyzer functionality, providing advanced electrical measurement and network monitoring capabilities alongside circuit protection.

Is ABB 1SDA071578R1 fixed or withdrawable?

This model is a fixed four-pole air circuit breaker equipped with rear horizontal terminals for installation within low-voltage switchgear.

Advanced Power Protection from ABB SACE Emax 2

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, sophisticated electronic protection and advanced measurement capabilities to support dependable, intelligent low-voltage power distribution in demanding industrial and infrastructure systems.