1SDA071561R1 ABB E2.2S 1000 Ekip Dip LI 4p FHR Air Circuit Breaker

1SDA071561R1 ABB E2.2S 1000 Ekip Dip LI 4p FHR Air Circuit Breaker

ABB 1SDA071561R1 SACE Emax 2 E2.2S 1000 A four-pole fixed air circuit breaker with rear horizontal terminals and Ekip Dip LI electronic overload and instantaneous short-circuit protection.

SKU: 1SDA071561R1MPN: 1SDA071561R1
Price
List Price £8,107.70 ex VAT
Your Price (ex VAT) Save 25%
£6,080.78 25% OFF
You save £2,026.93 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,080.78
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,080.78

Why Choose the ABB E2.2S 1000 Ekip Dip LI 4p FHR Air Circuit Breaker?

The ABB E2.2S 1000 Ekip Dip LI 4p FHR, order code 1SDA071561R1, is a high-performance four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for reliable protection and switching in demanding low-voltage power distribution systems. Its E2.2S frame combines high short-circuit performance with the straightforward and dependable Ekip Dip LI electronic trip unit.

Rated at 1000 A, this breaker has a fixed configuration with rear horizontal terminals and a 100% rated neutral pole. The Ekip Dip LI solid-state release provides adjustable long-time overload and instantaneous short-circuit protection, with settings configured through DIP switches for simple and effective circuit protection.

The E2.2S performance level provides an ultimate short-circuit breaking capacity of 85 kA at 380–440 V AC and 66 kA at 500–690 V AC. With a rated operational voltage of 690 V AC, rated insulation voltage of 1000 V AC and short-time withstand capability of 66 kA for 1 s, the 1SDA071561R1 is well suited to industrial and commercial distribution systems with substantial prospective fault currents.

Key Advantages

  • High-performance ABB SACE Emax 2 E2.2S air circuit breaker.
  • 1000 A rated current for high-capacity low-voltage distribution circuits.
  • Four-pole configuration with 100% rated neutral pole.
  • Ekip Dip LI electronic release provides overload and instantaneous short-circuit protection.
  • Simple protection adjustment using accessible DIP switches.
  • High 85 kA breaking capacity at 380–440 V AC.
  • 66 kA for 1 s short-time withstand capability supports robust distribution systems.
  • Fixed construction with rear horizontal terminals for switchboard integration.

Key Features

  • ABB SACE Emax 2 E2.2S air circuit breaker.
  • 1000 A rated uninterrupted current.
  • 4-pole construction.
  • 100% neutral pole current.
  • Fixed-mounted configuration.
  • Rear horizontal terminals.
  • Ekip Dip LI solid-state electronic release.
  • Long-time overload protection adjustable from 0.4–1 × In.
  • Instantaneous short-circuit protection adjustable from 1.5–15 × In.
  • 85 kA Icu at 380–440 V AC.
  • 66 kA Icu at 500–690 V AC.
  • Supplied with four auxiliary contacts and circuit-breaker open/closed position indication.

Dependable LI Protection with Ekip Dip

The Ekip Dip LI electronic trip unit provides the essential protection functions required for many low-voltage distribution applications. Long-time protection responds to sustained overload conditions, while instantaneous protection provides rapid interruption of severe short-circuit faults, with adjustment ranges of 0.4–1 × In and 1.5–15 × In respectively.

The ABB SACE Emax 2 E2.2S platform combines this straightforward electronic protection with high interruption capability and strong short-time withstand performance. Its 85 kA breaking capacity at common industrial voltages and fixed rear-horizontal connection arrangement make the 1SDA071561R1 a practical choice for high-capacity distribution switchboards.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Manufacturing and process facilities.
  • Commercial buildings and infrastructure.
  • Transformer distribution circuits.
  • Power control centres.
  • High-capacity electrical distribution panels.

Technical Specifications

Series SACE Emax 2 E2.2
Order code / MPN 1SDA071561R1
EAN 8015644754112
Product type Air circuit breaker (ACB)
Rated current (In) 1000 A
Rated uninterrupted current (Iu) 1000 A
Number of poles 4
Neutral pole current 100%
Performance level S
Trip unit Ekip Dip LI
Trip unit type Electronic / solid-state
Protection functions L (overload), I (instantaneous short circuit)
Overload protection adjustment 400–1000 A (0.4–1 × In)
Instantaneous protection adjustment 1500–15000 A (1.5–15 × In)
Adjustment method DIP switches
Mounting Fixed
Terminals Rear horizontal
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate breaking capacity (Icu) at 380 V AC 85 kA
Ultimate breaking capacity (Icu) at 400/415 V AC 85 kA
Ultimate breaking capacity (Icu) at 440 V AC 85 kA
Ultimate breaking capacity (Icu) at 500/525 V AC 66 kA
Ultimate breaking capacity (Icu) at 690 V AC 66 kA
Service breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw) 66 kA for 1 s; 50 kA for 3 s
Frequency 50/60 Hz
Power loss 53 W
Electrical durability 15000 cycles
Mechanical durability 25000 cycles
Auxiliary contacts 4
Circuit-breaker open/closed indication Yes
Dimensions (W × H × D) 366 × 371 × 270 mm
Net weight 53 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071561R1?

The ABB 1SDA071561R1 is a SACE Emax 2 E2.2S four-pole fixed air circuit breaker rated at 1000 A, equipped with rear horizontal terminals and an Ekip Dip LI electronic trip unit.

What protection functions does the Ekip Dip LI provide?

The Ekip Dip LI provides long-time overload (L) and instantaneous short-circuit (I) protection. The overload threshold is adjustable from 0.4–1 × In and instantaneous protection from 1.5–15 × In.

What is the breaking capacity of the ABB E2.2S 1000?

The E2.2S 1000 provides an ultimate short-circuit breaking capacity of 85 kA at 380–440 V AC and 66 kA at 500–690 V AC.

How are the protection settings adjusted on the Ekip Dip LI?

The protection thresholds are configured using DIP switches on the Ekip Dip electronic release, providing a straightforward method of setting the overload and instantaneous protection functions.

What terminal configuration does the ABB 1SDA071561R1 use?

This model is a fixed-mounted Emax 2 air circuit breaker equipped with rear horizontal terminals for integration into low-voltage switchboards.

Trusted Low-Voltage Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, dependable electronic protection and flexible switchboard integration to provide reliable switching and protection for modern low-voltage power distribution systems.