ABB 1SDA071561R1 SACE Emax 2 E2.2S 1000 A four-pole fixed air circuit breaker with rear horizontal terminals and Ekip Dip LI electronic overload and instantaneous short-circuit protection.
£6,080.78
The ABB E2.2S 1000 Ekip Dip LI 4p FHR, order code 1SDA071561R1, is a high-performance four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for reliable protection and switching in demanding low-voltage power distribution systems. Its E2.2S frame combines high short-circuit performance with the straightforward and dependable Ekip Dip LI electronic trip unit.
Rated at 1000 A, this breaker has a fixed configuration with rear horizontal terminals and a 100% rated neutral pole. The Ekip Dip LI solid-state release provides adjustable long-time overload and instantaneous short-circuit protection, with settings configured through DIP switches for simple and effective circuit protection.
The E2.2S performance level provides an ultimate short-circuit breaking capacity of 85 kA at 380–440 V AC and 66 kA at 500–690 V AC. With a rated operational voltage of 690 V AC, rated insulation voltage of 1000 V AC and short-time withstand capability of 66 kA for 1 s, the 1SDA071561R1 is well suited to industrial and commercial distribution systems with substantial prospective fault currents.
The Ekip Dip LI electronic trip unit provides the essential protection functions required for many low-voltage distribution applications. Long-time protection responds to sustained overload conditions, while instantaneous protection provides rapid interruption of severe short-circuit faults, with adjustment ranges of 0.4–1 × In and 1.5–15 × In respectively.
The ABB SACE Emax 2 E2.2S platform combines this straightforward electronic protection with high interruption capability and strong short-time withstand performance. Its 85 kA breaking capacity at common industrial voltages and fixed rear-horizontal connection arrangement make the 1SDA071561R1 a practical choice for high-capacity distribution switchboards.
| Series | SACE Emax 2 E2.2 |
|---|---|
| Order code / MPN | 1SDA071561R1 |
| EAN | 8015644754112 |
| Product type | Air circuit breaker (ACB) |
| Rated current (In) | 1000 A |
| Rated uninterrupted current (Iu) | 1000 A |
| Number of poles | 4 |
| Neutral pole current | 100% |
| Performance level | S |
| Trip unit | Ekip Dip LI |
| Trip unit type | Electronic / solid-state |
| Protection functions | L (overload), I (instantaneous short circuit) |
| Overload protection adjustment | 400–1000 A (0.4–1 × In) |
| Instantaneous protection adjustment | 1500–15000 A (1.5–15 × In) |
| Adjustment method | DIP switches |
| Mounting | Fixed |
| Terminals | Rear horizontal |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Ultimate breaking capacity (Icu) at 380 V AC | 85 kA |
| Ultimate breaking capacity (Icu) at 400/415 V AC | 85 kA |
| Ultimate breaking capacity (Icu) at 440 V AC | 85 kA |
| Ultimate breaking capacity (Icu) at 500/525 V AC | 66 kA |
| Ultimate breaking capacity (Icu) at 690 V AC | 66 kA |
| Service breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw) | 66 kA for 1 s; 50 kA for 3 s |
| Frequency | 50/60 Hz |
| Power loss | 53 W |
| Electrical durability | 15000 cycles |
| Mechanical durability | 25000 cycles |
| Auxiliary contacts | 4 |
| Circuit-breaker open/closed indication | Yes |
| Dimensions (W × H × D) | 366 × 371 × 270 mm |
| Net weight | 53 kg |
| Standard | IEC 60947-2 |
The ABB 1SDA071561R1 is a SACE Emax 2 E2.2S four-pole fixed air circuit breaker rated at 1000 A, equipped with rear horizontal terminals and an Ekip Dip LI electronic trip unit.
The Ekip Dip LI provides long-time overload (L) and instantaneous short-circuit (I) protection. The overload threshold is adjustable from 0.4–1 × In and instantaneous protection from 1.5–15 × In.
The E2.2S 1000 provides an ultimate short-circuit breaking capacity of 85 kA at 380–440 V AC and 66 kA at 500–690 V AC.
The protection thresholds are configured using DIP switches on the Ekip Dip electronic release, providing a straightforward method of setting the overload and instantaneous protection functions.
This model is a fixed-mounted Emax 2 air circuit breaker equipped with rear horizontal terminals for integration into low-voltage switchboards.
ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, dependable electronic protection and flexible switchboard integration to provide reliable switching and protection for modern low-voltage power distribution systems.