ABB 1SDA071555R1 Emax 2 E2.2N 1000 A four-pole fixed air circuit breaker with rear horizontal terminals and an Ekip Touch LSI electronic trip unit for selective overload and short-circuit protection in low-voltage power distribution systems.

SKU: 1SDA071555R1MPN: 1SDA071555R1
Price
List Price £7,795.87 ex VAT
Your Price (ex VAT) Save 25%
£5,846.90 25% OFF
You save £1,948.97 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,846.90
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,846.90

Why Choose the ABB E2.2N 1000 Ekip Touch LSI 4p FHR Air Circuit Breaker?

The ABB E2.2N 1000 Ekip Touch LSI 4p FHR, order code 1SDA071555R1, is a high-performance four-pole air circuit breaker (ACB) designed for protection and switching in low-voltage power distribution systems. As part of the ABB SACE Emax 2 series, it combines a 1000 A rated current with advanced electronic LSI protection and robust short-circuit performance for industrial, commercial and infrastructure installations.

This fixed circuit breaker is equipped with the Ekip Touch LSI electronic trip unit, providing long-time overload, short-time short-circuit and instantaneous short-circuit protection. The addition of adjustable short-time protection makes the LSI release particularly useful in distribution systems where selective coordination between protective devices is required, while the Ekip Touch interface supports straightforward configuration and monitoring.

The E2.2N platform is designed for demanding low-voltage distribution duties, with a rated operational voltage of up to 690 V AC and strong short-circuit interruption capability. Its four-pole, fixed configuration with rear horizontal terminals enables permanent integration into switchboards, distribution panels and busbar assemblies.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for low-voltage power distribution.
  • 1000 A rated current for demanding industrial, commercial and infrastructure applications.
  • Four-pole configuration for switching and protection of three-phase systems with neutral.
  • Ekip Touch LSI electronic trip unit provides overload and two-stage short-circuit protection.
  • Short-time protection supports improved selectivity and coordination between protective devices.
  • Touchscreen interface enables intuitive protection configuration and access to operating information.
  • Fixed construction provides a robust solution for permanent switchboard installations.
  • Rear horizontal terminals support efficient connection to switchboard busbar systems.

Key Features

  • ABB SACE Emax 2 E2.2N series.
  • 1000 A rated current.
  • Four-pole air circuit breaker.
  • Fixed mounting configuration.
  • Rear horizontal terminals.
  • Ekip Touch LSI electronic release.
  • Long-time overload protection.
  • Short-time selective short-circuit protection.
  • Instantaneous short-circuit protection.
  • Electronic touchscreen interface for protection settings and monitoring.
  • Designed for operation in low-voltage systems up to 690 V AC.
  • Suitable for selective protection schemes in high-current distribution networks.
  • Part of ABB's modular Emax 2 air circuit breaker platform.

Selective Protection for Low-Voltage Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 provide essential switching and protection for high-current low-voltage electrical systems. By detecting abnormal current conditions and interrupting the circuit when configured thresholds are exceeded, the breaker helps protect cables, busbars, switchgear and connected equipment against potentially damaging overload and short-circuit faults.

The Ekip Touch LSI release adds short-time protection between the long-time overload and instantaneous protection stages. This enables greater flexibility when coordinating multiple protective devices, helping downstream breakers clear localised faults before an upstream main breaker operates where the system design and protection settings permit selective operation.

Typical Applications

  • Main low-voltage electrical distribution switchboards.
  • Industrial power distribution systems.
  • Commercial building electrical infrastructure.
  • Manufacturing and process plant switchgear.
  • Transformer-fed distribution systems.
  • Systems requiring selective short-circuit protection.
  • Infrastructure and utility electrical distribution.
  • OEM low-voltage switchgear and busbar assemblies.

Technical Specifications

Product group Emax2 Air Circuit Breaker
Series SACE Emax 2 E2.2N
ABB order code 1SDA071555R1
EAN 8015644754051
Product type Air circuit breaker
Rated current 1000 A
Number of poles 4
Trip unit Ekip Touch LSI electronic release
Protection functions L (long-time overload), S (short-time short circuit) and I (instantaneous short circuit)
Earth-fault protection Not included in the LSI protection configuration
Rated operational voltage up to 690 V AC
Installation Fixed
Terminal arrangement Rear horizontal
Product family ABB SACE Emax 2

Frequently Asked Questions

What is the ABB 1SDA071555R1 used for?

The ABB 1SDA071555R1 is a four-pole air circuit breaker designed for switching and protection in high-current low-voltage power distribution systems, including industrial, commercial and infrastructure switchboards.

What is the rated current of the ABB E2.2N 1000?

The ABB E2.2N 1000 has a rated current of 1000 A, making it suitable for substantial low-voltage distribution circuits.

What protection does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI electronic trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. The short-time function supports selective coordination with other protective devices in the distribution system.

What is the difference between Ekip Touch LI and Ekip Touch LSI?

Ekip Touch LI provides long-time overload and instantaneous short-circuit protection, while Ekip Touch LSI adds a short-time short-circuit protection function that provides greater flexibility for selective protection and coordination.

What does FHR mean on the ABB E2.2N 1000?

The FHR configuration identifies this Emax 2 breaker as a fixed version with rear horizontal terminals, designed for permanent integration into compatible low-voltage switchboards and busbar systems.

Trusted Power Distribution Technology from ABB

ABB SACE Emax 2 air circuit breakers are engineered for dependable switching, electronic protection and power distribution, combining configurable trip technology with robust construction for demanding low-voltage electrical installations.