Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA071540R1 Emax 2 E2.2S 800 A four-pole fixed air circuit breaker with rear flat horizontal terminals, Ekip G Hi-Touch LSIG electronic protection and up to 85 kA breaking capacity for advanced generator and low-voltage power distribution protection.
£9,866.64
The ABB E2.2S 800 Ekip G Hi-Touch LSIG 4p FHR, order code 1SDA071540R1, is a high-performance four-pole air circuit breaker (ACB) designed for advanced generator and low-voltage power distribution protection. As part of the ABB SACE Emax 2 series, it combines an 800 A rated current, high short-circuit performance and the sophisticated Ekip G Hi-Touch LSIG electronic trip unit for demanding industrial, infrastructure and power-generation installations.
This fixed circuit breaker features the Ekip G Hi-Touch LSIG electronic release, combining long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection with advanced generator-oriented protection, measurement and monitoring capabilities. The Hi-Touch platform provides a high level of functionality for applications where accurate electrical data, configurable protection and effective coordination are required.
With a rated operational voltage of 690 V AC, four-pole construction and an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC, the 1SDA071540R1 provides robust protection for substantial low-voltage systems. Its fixed configuration uses rear flat horizontal terminals, enabling efficient integration with switchboard busbar systems.
Air circuit breakers such as the ABB SACE Emax 2 provide essential switching and fault protection for high-current low-voltage electrical systems. The Ekip G Hi-Touch platform is particularly suited to generator and advanced power-distribution applications, combining sophisticated electronic protection with measurement and monitoring capabilities to help safeguard generators, cables, busbars, switchgear and connected equipment.
The Ekip G Hi-Touch LSIG release combines long-time overload, short-time selective, instantaneous short-circuit and earth-fault protection with advanced functionality for generator applications. Together with the E2.2S breaker’s high breaking capacity and short-time withstand performance, this makes the 1SDA071540R1 particularly suitable for systems requiring dependable fault interruption, effective selectivity and comprehensive electrical protection.
| Product group | Emax2 Air Circuit Breaker |
|---|---|
| Series | SACE Emax 2 E2.2S |
| ABB order code | 1SDA071540R1 |
| EAN | 8015644753900 |
| Product type | Air circuit breaker |
| Rated current (In) | 800 A |
| Rated uninterrupted current (Iu) | 800 A |
| Number of poles | 4 |
| Neutral pole current | 100% |
| Trip unit | Ekip G Hi-Touch LSIG electronic release |
| Protection functions | L (overload), S (short-time short circuit), I (instantaneous short circuit) and G (earth fault) |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Ultimate breaking capacity (Icu) at 400 / 415 V AC | 85 kA |
| Ultimate breaking capacity (Icu) at 440 V AC | 85 kA |
| Ultimate breaking capacity (Icu) at 500 / 525 V AC | 66 kA |
| Ultimate breaking capacity (Icu) at 690 V AC | 66 kA |
| Service breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw) | 66 kA for 1 s; 50 kA for 3 s |
| Installation | Fixed |
| Terminal arrangement | Rear flat horizontal |
| Main circuit connection | Bolt connection |
| Auxiliary contacts | 4 change-over contacts |
| Protection rating | IP30 |
| Power loss | 34 W |
| Electrical durability | 15,000 operating cycles |
| Mechanical durability | 25,000 operating cycles |
| Dimensions (W × H × D) | 366 × 371 × 270 mm |
| Net weight | 53 kg |
| Standard | IEC 60947-2 |
The ABB 1SDA071540R1 is a four-pole air circuit breaker designed for generator protection, switching and advanced fault protection in high-current low-voltage power distribution systems.
This Emax 2 air circuit breaker has a rated uninterrupted current of 800 A.
The Ekip G Hi-Touch LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, together with advanced generator-oriented protection, measurement and monitoring functionality.
The E2.2S has an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC, with a rated service breaking capacity equal to 100% of Icu.
The FHR configuration identifies this Emax 2 breaker as a fixed version with rear flat horizontal terminals, designed for permanent integration into compatible low-voltage switchboards and busbar systems.
ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, switching, measurement and power-management capabilities for demanding low-voltage systems, with Ekip G Hi-Touch releases providing sophisticated functionality for generator and power-generation applications.