1SDA071534R1 ABB Emax 2 E2.2S 800A Ekip Touch LI 4P FHR Air Circuit Breaker

1SDA071534R1 ABB Emax 2 E2.2S 800A Ekip Touch LI 4P FHR Air Circuit Breaker

ABB 1SDA071534R1 is a SACE Emax 2 E2.2S 800 A fixed four-pole air circuit breaker with rear horizontal terminals, an Ekip Touch LI electronic trip unit, rated operational voltage up to 690 V AC and 85 kA breaking capacity at 380–440 V AC.

SKU: 1SDA071534R1MPN: 1SDA071534R1
Price
List Price £7,990.77 ex VAT
Your Price (ex VAT) Save 25%
£5,993.08 25% OFF
You save £1,997.69 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,993.08
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,993.08

Why Choose the ABB 1SDA071534R1 Emax 2 Air Circuit Breaker?

The ABB 1SDA071534R1 is a high-performance SACE Emax 2 E2.2S air circuit breaker (ACB) designed for dependable protection and control of demanding low-voltage electrical distribution systems. Rated at 800 A, this fixed four-pole circuit breaker combines ABB’s E2.2S frame with the advanced Ekip Touch LI solid-state electronic trip unit for configurable long-time overload and instantaneous short-circuit protection.

As part of the ABB SACE Emax 2 series, the E2.2S offers high short-circuit performance together with advanced electronic protection and a touchscreen-based user interface. The Ekip Touch LI release provides long-time and instantaneous protection functions, making this configuration particularly suitable where sophisticated electronic control and monitoring are required without short-time delayed or integrated ground-fault protection.

With a rated uninterrupted current of 800 A, rated operational voltage up to 690 V AC, rated ultimate short-circuit breaking capacity of 85 kA at 380–440 V AC and rated short-time withstand current of 66 kA for 1 s, the 1SDA071534R1 provides substantial fault-handling capability. This version features a fixed four-pole configuration with rear horizontal terminals for practical integration with switchboard busbar systems.

Key Advantages

  • High-performance 800 A air circuit breaker for demanding low-voltage power distribution.
  • 85 kA ultimate short-circuit breaking capacity at 380–440 V AC.
  • 66 kA rated short-time withstand current for 1 s supports effective selectivity and protection coordination.
  • Advanced Ekip Touch LI electronic trip unit provides adjustable overload and instantaneous short-circuit protection.
  • Touch-sensitive interface simplifies protection configuration, commissioning and operation.
  • 100% Ics-to-Icu performance provides strong service short-circuit breaking capability.
  • Four-pole fixed configuration with rear horizontal terminals supports efficient busbar integration.
  • High mechanical and electrical endurance supports demanding switchboard applications.

Key Features

  • ABB SACE Emax 2 E2.2S air circuit breaker.
  • 800 A rated uninterrupted current.
  • Rated operational voltage up to 690 V AC.
  • 1000 V AC rated insulation voltage.
  • 85 kA Icu at 380–440 V AC.
  • 66 kA Icu at 500–690 V AC.
  • 66 kA Icw for 1 s and 50 kA Icw for 3 s.
  • Ekip Touch LI solid-state electronic release.
  • Long-time overload and instantaneous short-circuit protection.
  • Adjustable long-time overload protection from 320–800 A.
  • Touch-sensitive interface for electronic protection configuration.
  • Fixed four-pole construction with neutral pole rated at 100% of Iu.
  • Rear flat horizontal terminals for main circuit connections.
  • Supplied with four auxiliary contacts.
  • Open/closed circuit-breaker position indication.
  • Designed for high-performance IEC low-voltage distribution systems.

High-Performance Protection for Low-Voltage Distribution

Air circuit breakers such as the ABB SACE Emax 2 E2.2S protect important low-voltage distribution circuits against damaging overload and short-circuit conditions. The 1SDA071534R1 combines an 800 A continuous-current rating with 85 kA ultimate short-circuit breaking capability at 380–440 V AC and 66 kA short-time withstand capability for 1 s, making it suitable for demanding main incomers and distribution circuits.

The Ekip Touch LI trip unit provides configurable electronic long-time and instantaneous protection through an intuitive touchscreen interface. Combined with the breaker’s high fault capability, four-pole construction and rear horizontal terminal arrangement, this configuration is well suited to switchboards requiring advanced electronic protection and practical rear busbar connectivity.

Typical Applications

  • Main incoming protection for low-voltage switchboards.
  • Industrial electrical distribution systems.
  • Commercial building power distribution.
  • Transformer secondary protection.
  • Manufacturing and process facilities.
  • Distribution feeders requiring high short-circuit performance.
  • Data centres and critical-power installations.
  • Low-voltage switchgear with rear busbar connections.

Technical Specifications

Series SACE Emax 2
Frame / sub-type E2.2S
Order code / MPN 1SDA071534R1
EAN / GTIN 8015644753849
Product type Air circuit breaker
Short-circuit performance level S
Rated current (In) 800 A
Rated uninterrupted current (Iu) 800 A
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50 / 60 Hz
Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw) for 1 s 66 kA
Rated short-time withstand current (Icw) for 3 s 50 kA
Number of poles 4
Neutral pole current 100% of Iu
Trip unit Ekip Touch LI
Release type Solid-state electronic
Protection functions LI
Overload protection adjustment 0.4–1 × In
Overload protection adjustment range 320–800 A
Long-time overload protection Yes
Instantaneous short-circuit protection Yes
Short-time delayed protection No
Integrated ground-fault protection No
User interface Touch-sensitive display
Current type AC
Installation version Fixed
Terminal configuration Rear flat horizontal
Main circuit connection Bolted connection
Auxiliary contacts 4
Circuit-breaker position indication Open / closed
Power loss 34 W
Electrical durability at ≤440 V AC 15,000 operating cycles
Electrical durability at 500–690 V AC 15,000 operating cycles
Mechanical durability 25,000 operating cycles
Country of origin Italy
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA071534R1 used for?

The ABB 1SDA071534R1 is an 800 A Emax 2 air circuit breaker designed to protect and control demanding low-voltage electrical distribution circuits in industrial, commercial and infrastructure switchboards.

What is the current rating of the ABB 1SDA071534R1?

The ABB 1SDA071534R1 has a rated uninterrupted current of 800 A and is designed for AC low-voltage distribution systems with rated operational voltage up to 690 V AC.

What breaking capacity does the E2.2S 800 provide?

The E2.2S 800 provides a rated ultimate short-circuit breaking capacity of 85 kA at 380–440 V AC and 66 kA at 500–690 V AC, with a rated short-time withstand current of 66 kA for 1 s.

What protection does the Ekip Touch LI trip unit provide?

The Ekip Touch LI solid-state electronic trip unit provides configurable long-time overload and instantaneous short-circuit protection. This LI configuration does not include short-time delayed or integrated ground-fault protection.

What terminal configuration does the ABB 1SDA071534R1 use?

The 1SDA071534R1 is a fixed four-pole air circuit breaker with rear flat horizontal terminals, providing a practical connection arrangement for busbars within low-voltage switchboard assemblies.

Trusted High-Performance Circuit Protection

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, high short-circuit performance, strong electrical endurance and flexible installation configurations for dependable operation in modern industrial, commercial and critical-power low-voltage distribution systems.