1SDA071529R1 ABB E2.2N 800 Ekip Hi-Touch LSIG 4p FHR Air Circuit Breaker 800 A

1SDA071529R1 ABB E2.2N 800 Ekip Hi-Touch LSIG 4p FHR Air Circuit Breaker 800 A

ABB 1SDA071529R1 Emax 2 E2.2N 800 four-pole fixed air circuit breaker with an 800 A rating, Ekip Hi-Touch LSIG electronic protection, rear horizontal terminals and 66 kA ultimate breaking capacity at 440 V AC.

SKU: 1SDA071529R1MPN: 1SDA071529R1
Price
List Price £12,005.64 ex VAT
Your Price (ex VAT) Save 25%
£9,004.23 25% OFF
You save £3,001.41 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,004.23
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,004.23

Why Choose the ABB E2.2N 800 Ekip Hi-Touch LSIG 4p FHR Air Circuit Breaker?

The ABB E2.2N 800 Ekip Hi-Touch LSIG 4p FHR, order code 1SDA071529R1, is a high-performance four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for protection, switching and advanced monitoring in demanding low-voltage electrical distribution systems. Combining the E2.2 frame with the N performance level and Ekip Hi-Touch LSIG electronic trip unit, it provides comprehensive protection for industrial, commercial and infrastructure power networks.

This fixed circuit breaker features rear horizontal terminals and an Ekip Hi-Touch LSIG solid-state electronic release. Its LSIG functionality provides long-time overload, selective short-time short-circuit, instantaneous short-circuit and earth-fault protection, giving system designers a comprehensive protection platform for important distribution circuits.

With a rated uninterrupted current of 800 A, an ultimate short-circuit breaking capacity of 66 kA at 440 V AC and a rated short-time withstand current of 66 kA for 1 s, the E2.2N 800 is designed for installations with substantial prospective fault currents. Its four-pole configuration enables switching across three phases and neutral, while the fixed rear-horizontal connection arrangement supports permanent integration into low-voltage switchboards.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage power distribution.
  • 800 A rated uninterrupted current for industrial, commercial and infrastructure electrical loads.
  • 66 kA ultimate short-circuit breaking capacity at 440 V AC for installations with high prospective fault currents.
  • 66 kA short-time withstand current for 1 s supports demanding selective distribution applications.
  • Ekip Hi-Touch LSIG electronic trip unit provides comprehensive overload, short-circuit and earth-fault protection.
  • Selective short-time protection supports coordination between upstream and downstream protective devices.
  • Integrated earth-fault protection adds protection against ground-fault conditions.
  • Ekip Hi-Touch technology provides advanced measurement and monitoring capabilities.
  • Four-pole configuration enables switching across three phases and neutral.
  • Fixed construction with rear horizontal terminals for switchboard busbar integration.

Key Features

  • ABB SACE Emax 2 E2.2N series.
  • 800 A rated uninterrupted current.
  • Four-pole air circuit breaker.
  • 66 kA Icu at 440 V AC.
  • 66 kA Icw for 1 s.
  • Ekip Hi-Touch LSIG solid-state electronic protection release.
  • Long-time overload (L) protection.
  • Selective short-time short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • Earth-fault (G) protection.
  • Advanced Ekip Hi-Touch measurement and monitoring functionality.
  • Fitted with four auxiliary contacts.
  • Circuit-breaker open/closed position indication.
  • Fixed version with rear horizontal terminals.

Advanced LSIG Protection for Selective Power Distribution

The ABB SACE Emax 2 E2.2N combines substantial short-circuit capability with an advanced electronic protection platform for critical low-voltage distribution duties. Its 800 A rated current, 66 kA ultimate breaking capacity at 440 V AC and 66 kA short-time withstand capability for 1 s make it suitable for main incomers, distribution feeders and other circuits where high prospective fault currents must be safely managed.

The Ekip Hi-Touch LSIG release combines four complementary protection functions. Long-time protection responds to sustained overloads, selective short-time protection supports coordinated fault clearing, instantaneous protection responds rapidly to severe short circuits, and earth-fault protection addresses fault current flowing to earth. Combined with the advanced capabilities of the Hi-Touch platform, this provides a versatile solution for sophisticated low-voltage distribution networks.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial electrical distribution systems.
  • Commercial building power distribution.
  • Manufacturing and process plants.
  • Main incomer and feeder circuit protection.
  • Transformer secondary distribution systems.
  • Distribution systems requiring selective short-circuit and earth-fault protection.
  • Critical power systems requiring advanced electronic protection and monitoring.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA071529R1
EAN / GTIN 8015644753795
Product type Air circuit breaker
Frame E2.2
Performance level N
Rated uninterrupted current (Iu) 800 A
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 66 kA
Rated short-time withstand current (Icw) 66 kA for 1 s
Number of poles 4
Current type AC
Trip unit Ekip Hi-Touch LSIG
Release type Solid-state electronic
Protection functions Long-time overload, selective short-time short-circuit, instantaneous short-circuit and earth-fault protection
Integrated earth-fault protection Yes
Version Fixed
Terminal orientation Rear horizontal
Auxiliary contacts 4
Position indication Circuit breaker open / closed

Frequently Asked Questions

What is the ABB 1SDA071529R1 used for?

The ABB 1SDA071529R1 is an Emax 2 air circuit breaker designed for switching, comprehensive electronic protection and advanced monitoring in demanding low-voltage electrical distribution systems.

What is the current rating of the ABB E2.2N 800?

The circuit breaker has a rated uninterrupted current of 800 A, making it suitable for substantial industrial, commercial and infrastructure electrical loads.

What is the breaking capacity of the ABB 1SDA071529R1?

The ABB E2.2N 800 has a rated ultimate short-circuit breaking capacity (Icu) of 66 kA at 440 V AC and a rated short-time withstand current (Icw) of 66 kA for 1 s.

What protection unit is fitted to the ABB E2.2N 800?

The breaker is fitted with an ABB Ekip Hi-Touch LSIG electronic trip unit, providing long-time overload, selective short-time short-circuit, instantaneous short-circuit and earth-fault protection.

What does FHR mean on the ABB 1SDA071529R1?

The 1SDA071529R1 is a fixed four-pole circuit breaker with rear horizontal terminals, an arrangement designed for permanent integration with the switchboard busbar system.

Advanced Low-Voltage Protection from ABB