ABB 1SDA071526R1 Emax 2 E2.2N 800 A four-pole fixed air circuit breaker with rear flat horizontal terminals, Ekip Touch LSIG electronic protection and 66 kA breaking capacity for demanding low-voltage power distribution systems.
£6,256.19
The ABB E2.2N 800 Ekip Touch LSIG 4p FHR, order code 1SDA071526R1, is a high-performance four-pole air circuit breaker (ACB) designed for protection, switching and monitoring in low-voltage power distribution systems. As part of the advanced ABB SACE Emax 2 series, it combines a 800 A rated current with comprehensive electronic LSIG protection and a high short-circuit breaking capacity for demanding industrial, commercial and infrastructure installations.
This fixed circuit breaker is equipped with the Ekip Touch LSIG electronic trip unit, providing long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection. Its touch-sensitive display enables straightforward configuration of protection settings, helping engineers achieve effective selectivity, coordination and protection throughout modern electrical distribution systems.
With a rated operational voltage of up to 690 V AC and an ultimate short-circuit breaking capacity of 66 kA at 380–690 V AC, the 1SDA071526R1 provides robust fault protection across a wide range of low-voltage applications. Its fixed four-pole configuration uses rear flat horizontal terminals, making it particularly suitable for integration into substantial switchboard and busbar assemblies.
Air circuit breakers such as the ABB SACE Emax 2 protect high-current electrical distribution systems against overloads, short circuits and earth faults. By automatically interrupting the circuit when configured protection thresholds are exceeded, the breaker helps protect cables, busbars, switchgear and connected equipment while supporting dependable operation of the wider electrical installation.
The Ekip Touch LSIG trip unit combines long-time overload, short-time selective, instantaneous short-circuit and earth-fault protection with an intuitive touch-sensitive interface. This comprehensive protection package makes the E2.2N particularly suitable for main and distribution switchboards where high breaking capacity, effective selectivity and flexible electronic protection are required.
| Product group | Emax2 Air Circuit Breaker |
|---|---|
| Series | SACE Emax 2 E2.2N |
| ABB order code | 1SDA071526R1 |
| EAN | 8015644753764 |
| Product type | Air circuit breaker |
| Rated current | 800 A |
| Rated uninterrupted current (Iu) | 800 A |
| Number of poles | 4 |
| Neutral pole current | 100% |
| Trip unit | Ekip Touch LSIG electronic release |
| Protection functions | L (overload), S (short-time short circuit), I (instantaneous short circuit) and G (earth fault) |
| Overload protection adjustment | 0.4–1 × In |
| Instantaneous protection adjustment | 1.5–15 × In |
| Earth-fault protection adjustment | 0.1–1 × In |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Ultimate breaking capacity (Icu) at 380 V AC | 66 kA |
| Ultimate breaking capacity (Icu) at 400 / 415 V AC | 66 kA |
| Ultimate breaking capacity (Icu) at 440 V AC | 66 kA |
| Ultimate breaking capacity (Icu) at 500 / 525 V AC | 66 kA |
| Ultimate breaking capacity (Icu) at 690 V AC | 66 kA |
| Service breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw) | 66 kA for 1 s; 50 kA for 3 s |
| Frequency | 50 / 60 Hz |
| Installation | Fixed |
| Terminal arrangement | Rear flat horizontal |
| Main terminal type | Bolt connection |
| Mechanical durability | 25,000 operating cycles |
| Power loss | 34 W |
| Standard | IEC 60947-2 |
The ABB 1SDA071526R1 is a four-pole air circuit breaker used for switching and protection in high-current low-voltage power distribution systems, including industrial, commercial and infrastructure switchboards.
This Emax 2 air circuit breaker has a rated uninterrupted current of 800 A.
The Ekip Touch LSIG electronic trip unit provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection, with settings configured through its touch-sensitive interface.
The E2.2N has an ultimate short-circuit breaking capacity of 66 kA at 380–690 V AC, providing robust fault-current interruption across a wide range of low-voltage distribution applications.
The FHR configuration identifies this Emax 2 breaker as a fixed version with rear flat horizontal terminals, suitable for permanent integration into compatible low-voltage switchboards and busbar systems.
ABB SACE Emax 2 air circuit breakers are engineered for dependable switching, protection and monitoring in modern low-voltage power distribution systems, combining advanced electronic trip technology with robust short-circuit performance for demanding electrical installations.