1SDA071517R1 ABB E1.2N 1600 Ekip G Touch LSIG 4-Pole Air Circuit Breaker

1SDA071517R1 ABB E1.2N 1600 Ekip G Touch LSIG 4-Pole Air Circuit Breaker

ABB 1SDA071517R1 is a SACE Emax 2 E1.2N 1600 A fixed four-pole air circuit breaker with front terminals and an Ekip G Touch LSIG electronic trip unit providing advanced generator-oriented overload, short-circuit and earth-fault protection for low-voltage power systems.

SKU: 1SDA071517R1MPN: 1SDA071517R1
Price
List Price £12,218.26 ex VAT
Your Price (ex VAT) Save 25%
£9,163.70 25% OFF
You save £3,054.57 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,163.70
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,163.70

Why Choose the ABB 1SDA071517R1 E1.2N 1600 Ekip G Touch LSIG Air Circuit Breaker?

The ABB 1SDA071517R1 is a high-performance SACE Emax 2 E1.2N air circuit breaker designed for advanced protection and switching in low-voltage power distribution and generator applications. Rated at 1600 A, this four-pole fixed breaker combines ABB's compact E1.2N frame with the specialised Ekip G Touch LSIG electronic trip unit.

The Ekip G Touch LSIG release provides long-time overload (L), short-time overcurrent (S), instantaneous overcurrent (I) and earth-fault (G) protection together with additional functions dedicated to generator protection. ABB's Ekip G Touch platform also supports thermal memory, closing-on-short-circuit protection, external earth-fault protection, neutral protection, start-up functions and zone selectivity for S and G protection.

The 1SDA071517R1 is supplied in a fixed four-pole configuration with front terminals. Its 1600 A rating, 690 V AC capability and 66 kA breaking capacity make it suitable for demanding industrial, infrastructure and generator-connected low-voltage systems requiring sophisticated electronic protection and dependable fault interruption.

Key Advantages

  • 1600 A SACE Emax 2 air circuit breaker for high-current low-voltage distribution systems.
  • Compact E1.2N frame combines high electrical performance with efficient switchboard integration.
  • Specialised Ekip G Touch LSIG electronic trip unit with generator-oriented protection functions.
  • Long-time, short-time, instantaneous and earth-fault protection.
  • Zone selectivity support for short-time and earth-fault protection functions.
  • Integrated Ekip Measuring Pro measurement and protection functionality.
  • 66 kA breaking capacity for demanding fault-protection requirements.
  • Four-pole fixed construction with front terminals for permanent switchboard installation.

Key Features

  • ABB SACE Emax 2 E1.2N series.
  • 1600 A rated current.
  • 4-pole fixed configuration.
  • Front terminal connections.
  • Ekip G Touch LSIG electronic protection release.
  • Long-time overload protection (L / ANSI 49).
  • Time-delayed overcurrent protection (S / ANSI 51 and 50TD).
  • Instantaneous overcurrent protection (I / ANSI 50).
  • Earth-fault protection (G / ANSI 51N and 50NTD).
  • External earth-fault protection capability (G ext).
  • Closing-on-short-circuit protection (MCR).
  • Thermal memory and neutral protection functions.
  • Start-up protection functionality.
  • Zone selectivity for S and G functions.
  • Ekip Measuring Pro supplied as standard with the Ekip G Touch platform.
  • High-resolution touchscreen interface for measurements, alarms and configuration.

Generator-Oriented LSIG Protection for Critical Power Systems

The ABB Ekip G Touch platform extends the capabilities of the standard Ekip Touch family with protection functions specifically intended for generator applications. Alongside conventional LSI protection, the trip unit provides earth-fault protection, external earth-fault capability, thermal memory, neutral protection, start-up functionality, closing-on-short-circuit protection and zone selectivity for the S and G functions.

Combined with the 1600 A E1.2N breaker frame, Ekip Measuring Pro and a high-resolution touchscreen interface, the 1SDA071517R1 provides a sophisticated protection platform for generator-connected switchboards and critical low-voltage distribution systems where protection coordination, measurement and reliable interruption of high fault currents are essential.

Typical Applications

  • Low-voltage generator protection systems.
  • Generator-connected main switchboards.
  • Standby and emergency power distribution.
  • Industrial power generation installations.
  • Critical infrastructure electrical systems.
  • High-current low-voltage switchboard incomers.
  • Transformer and generator distribution networks.
  • Systems requiring integrated earth-fault protection.
  • Distribution networks requiring S and G zone selectivity.

Technical Specifications

Series SACE Emax 2
Frame E1.2N
ABB order code 1SDA071517R1
EAN 8015644753672
Product type Air circuit breaker
Rated current 1600 A
Number of poles 4
Installation Fixed
Main terminal arrangement Front terminals
Trip unit Ekip G Touch LSIG
Release type Electronic
Primary protection functions Long-time (L), short-time (S), instantaneous (I), earth fault (G)
Generator protection Dedicated Ekip G Touch protection functions
Long-time protection L / ANSI 49
Short-time protection S / ANSI 51 and 50TD
Instantaneous protection I / ANSI 50
Earth-fault protection G / ANSI 51N and 50NTD
External earth-fault protection G ext / ANSI 51G and 50GTD
Closing-on-short-circuit protection MCR
Zone selectivity S and G functions
Measurement module Ekip Measuring Pro
Interface High-resolution touchscreen display
Rated operational voltage up to 690 V AC
Breaking capacity 66 kA
Rated short-time withstand current (Icw) 50 kA for 1 s
Neutral pole current-carrying capacity 100% of Iu
Product width 280 mm
Product depth 183 mm
Product weight 18 kg
Country of origin Italy
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071517R1?

The ABB 1SDA071517R1 is a SACE Emax 2 E1.2N 1600 A four-pole fixed air circuit breaker with front terminals and an Ekip G Touch LSIG electronic trip unit.

What protection functions does the Ekip G Touch LSIG trip unit provide?

The Ekip G Touch LSIG release provides long-time overload, short-time overcurrent, instantaneous overcurrent and earth-fault protection, together with additional generator-oriented functions including thermal memory, MCR, external earth-fault protection, neutral protection, start-up functionality and S/G zone selectivity.

What is special about the Ekip G Touch trip unit?

The Ekip G Touch is designed to extend standard Ekip Touch functionality with dedicated generator protection functions, making it particularly suitable for generator-connected low-voltage power systems.

What is the breaking capacity of the ABB 1SDA071517R1?

The E1.2N 1600 configuration provides a breaking capacity of 66 kA, supporting demanding low-voltage fault-protection applications.

Does the ABB 1SDA071517R1 include earth-fault protection?

Yes. Its LSIG protection configuration includes integrated G earth-fault protection, and the Ekip G Touch platform also supports external earth-fault protection using an appropriate external current sensor.

Does the Ekip G Touch support zone selectivity?

Yes. The Ekip G Touch supports zone selectivity for the short-time S and earth-fault G protection functions, allowing coordinated protection strategies to be implemented in suitable electrical systems.

Does the Ekip G Touch include electrical measurement capabilities?

Yes. Ekip Measuring Pro is supplied as standard with the Ekip G Touch platform, providing advanced electrical measurement and protection functionality.

Is the ABB 1SDA071517R1 fixed or withdrawable?

This model is a fixed four-pole air circuit breaker with front terminals, intended for permanent installation within a suitable low-voltage switchboard or power distribution assembly.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, measurement and system-integration capabilities with robust switching performance for industrial, commercial, infrastructure and power-generation applications.