1SDA071515R1 ABB E1.2N 1600 Ekip Touch LSI 4p F F Air Circuit Breaker 1600 A

1SDA071515R1 ABB E1.2N 1600 Ekip Touch LSI 4p F F Air Circuit Breaker 1600 A

ABB 1SDA071515R1 Emax 2 E1.2N 1600 four-pole fixed air circuit breaker with a 1600 A rating, Ekip Touch LSI electronic protection, front terminals and 66 kA ultimate breaking capacity at 400 V AC.

SKU: 1SDA071515R1MPN: 1SDA071515R1
Price
List Price £8,225.78 ex VAT
Your Price (ex VAT) Save 25%
£6,169.34 25% OFF
You save £2,056.45 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,169.34
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,169.34

Why Choose the ABB E1.2N 1600 Ekip Touch LSI 4p F F Air Circuit Breaker?

The ABB E1.2N 1600 Ekip Touch LSI 4p F F, order code 1SDA071515R1, is a high-performance four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for protection and switching in demanding low-voltage electrical distribution systems. Combining the compact E1.2 frame with the N performance level and an Ekip Touch LSI electronic trip unit, it provides configurable protection for high-current industrial, commercial and infrastructure power networks.

This fixed circuit breaker features front terminals and an Ekip Touch LSI solid-state electronic release, providing long-time overload, selective short-time short-circuit and instantaneous short-circuit protection. The selective short-time function supports coordination with downstream protective devices, while the Ekip Touch interface provides convenient access to protection settings and operating information.

With a rated uninterrupted current of 1600 A, a rated voltage of 690 V AC and an ultimate short-circuit breaking capacity of 66 kA at 400 V AC, the E1.2N 1600 is designed for substantial electrical loads and high prospective fault currents. Its four-pole configuration enables switching across three phases and neutral, while its fixed construction and front terminals provide a practical arrangement for permanent switchboard installation.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage power distribution.
  • 1600 A rated uninterrupted current for high-current industrial and commercial electrical loads.
  • 66 kA ultimate short-circuit breaking capacity at 400 V AC for installations with substantial prospective fault currents.
  • Ekip Touch LSI electronic trip unit provides overload, selective short-time and instantaneous short-circuit protection.
  • Adjustable short-time protection supports selective coordination between upstream and downstream protective devices.
  • Overload protection can be adjusted across 640–1600 A.
  • Short-time delayed short-circuit protection can be adjusted across 960–16000 A.
  • Instantaneous short-circuit protection can be adjusted across 2400–24000 A.
  • Four-pole configuration enables switching across three phases and neutral.
  • Fixed construction with front terminal connections for permanent switchboard installation.

Key Features

  • ABB SACE Emax 2 E1.2N series.
  • 1600 A rated uninterrupted current.
  • Four-pole air circuit breaker.
  • 690 V AC rated voltage.
  • 66 kA Icu at 400 V AC.
  • Ekip Touch LSI solid-state electronic protection release.
  • Long-time overload (L) protection.
  • Selective short-time short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • Overload protection adjustment range of 640–1600 A.
  • Short-time delayed short-circuit adjustment range of 960–16000 A.
  • Instantaneous short-circuit adjustment range of 2400–24000 A.
  • No integrated earth-fault protection.
  • Fitted with four changeover auxiliary contacts.
  • Circuit-breaker open/closed position indication.
  • Optional motor drive capability.
  • IP30 degree of protection.
  • Fixed version with front terminals.

Selective LSI Protection for High-Current Distribution

The ABB SACE Emax 2 E1.2N combines a compact air circuit breaker platform with substantial current capacity and high short-circuit performance. Its 1600 A rating and 66 kA ultimate breaking capacity at 400 V AC make it suitable for main incomers, distribution feeders and other high-current circuits where dependable interruption of severe short-circuit faults is required.

The Ekip Touch LSI release combines three complementary protection functions. Long-time overload protection is adjustable from 640–1600 A, short-time delayed protection from 960–16000 A, and instantaneous protection from 2400–24000 A. This flexibility supports selective coordination so that downstream faults can be isolated while helping maintain continuity of supply to unaffected parts of the electrical distribution system.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial electrical distribution systems.
  • Commercial building power distribution.
  • Manufacturing and process plants.
  • Main incomer and high-current feeder protection.
  • Transformer secondary distribution systems.
  • Infrastructure electrical distribution.
  • Distribution systems requiring selective short-circuit protection.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA071515R1
EAN / GTIN 8015644753658
Product type Air circuit breaker
Frame E1.2
Performance level N
Rated uninterrupted current (Iu) 1600 A
Rated voltage 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 66 kA
Number of poles 4
Current type AC
Trip unit Ekip Touch LSI
Release type Solid-state electronic
Overload protection adjustment 640–1600 A
Short-time delayed short-circuit adjustment 960–16000 A
Instantaneous short-circuit adjustment 2400–24000 A
Protection functions Long-time overload, selective short-time short-circuit and instantaneous short-circuit protection
Integrated earth-fault protection No
Version Fixed
Terminal connection Front terminals
Auxiliary contacts 4 changeover contacts
Position indication Circuit breaker open / closed
Motor drive integrated No
Motor drive Optional
Degree of protection IP30
Product width 284 mm
Product height 295 mm
Product depth 184 mm
Net weight 11 kg
Mechanical durability 20000 cycles
Country of origin Italy

Frequently Asked Questions

What is the ABB 1SDA071515R1 used for?

The ABB 1SDA071515R1 is an Emax 2 air circuit breaker designed for switching and configurable overload, selective short-time and instantaneous short-circuit protection in high-current low-voltage electrical distribution systems.

What is the current rating of the ABB E1.2N 1600?

The circuit breaker has a rated uninterrupted current of 1600 A, with its overload protection adjustable from 640–1600 A.

What is the breaking capacity of the ABB 1SDA071515R1?

The ABB E1.2N 1600 has a rated ultimate short-circuit breaking capacity (Icu) of 66 kA at 400 V AC, making it suitable for demanding low-voltage systems with high prospective fault currents.

What protection unit is fitted to the ABB E1.2N 1600?

The breaker is fitted with an ABB Ekip Touch LSI electronic trip unit, providing long-time overload, selective short-time short-circuit and instantaneous short-circuit protection. Integrated earth-fault protection is not included on this LSI version.

Is the ABB 1SDA071515R1 fixed or withdrawable?

The 1SDA071515R1 is a fixed four-pole air circuit breaker with front terminals, designed for permanent installation within a low-voltage electrical switchboard.

Trusted High-Current Protection from ABB

ABB SACE Emax 2 air circuit breakers combine dependable switching, configurable electronic protection and high short-circuit performance for demanding low-voltage distribution systems across industrial, commercial and infrastructure applications.