1SDA071510R1 ABB E1.2C 1600 Ekip G Hi-Touch LSIG 4p F F Air Circuit Breaker

1SDA071510R1 ABB E1.2C 1600 Ekip G Hi-Touch LSIG 4p F F Air Circuit Breaker

ABB 1SDA071510R1 SACE Emax 2 E1.2C 1600 A four-pole fixed air circuit breaker with Ekip G Hi-Touch LSIG electronic protection for advanced low-voltage distribution and generator applications.

SKU: 1SDA071510R1MPN: 1SDA071510R1
Price
List Price £12,138.04 ex VAT
Your Price (ex VAT) Save 25%
£9,103.53 25% OFF
You save £3,034.51 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,103.53
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,103.53

Why Choose the ABB E1.2C 1600 Ekip G Hi-Touch LSIG 4p F F Air Circuit Breaker?

The ABB E1.2C 1600 Ekip G Hi-Touch LSIG 4p F F, order code 1SDA071510R1, is a high-performance four-pole air circuit breaker (ACB) designed for advanced protection, switching and generator applications in low-voltage power distribution systems. As part of the ABB SACE Emax 2 E1.2 series, it combines a compact fixed breaker platform with the advanced Ekip G Hi-Touch LSIG electronic trip unit.

Rated at 1600 A, this E1.2C breaker features a fixed installation configuration with front terminals and a 100% rated neutral pole. The Ekip G Hi-Touch LSIG electronic release provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection, together with advanced generator-oriented protection and monitoring capabilities.

The E1.2C performance level provides an ultimate short-circuit breaking capacity of 50 kA at 400–440 V AC and 42 kA at 500–690 V AC. With a rated operational voltage of 690 V AC, rated insulation voltage of 1000 V AC and rated impulse withstand voltage of 12 kV, the 1SDA071510R1 is engineered for demanding industrial, infrastructure and generator power systems.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker for demanding low-voltage distribution.
  • 1600 A rated current for high-capacity power circuits.
  • Four-pole configuration with 100% neutral pole current capability.
  • Ekip G Hi-Touch LSIG electronic trip unit for advanced protection and monitoring.
  • Provides overload, selective short-circuit, instantaneous and earth-fault protection.
  • Generator-oriented Ekip G functionality supports demanding generation applications.
  • Ultimate short-circuit breaking capacity up to 50 kA.
  • Fixed construction with front terminals for switchboard integration.

Key Features

  • ABB SACE Emax 2 E1.2C air circuit breaker.
  • 1600 A rated uninterrupted current.
  • 4-pole construction.
  • 100% rated neutral pole.
  • Fixed-mounted configuration.
  • Front terminals.
  • Ekip G Hi-Touch LSIG electronic release.
  • Long-time overload protection.
  • Short-time selective short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • Advanced touchscreen-based protection, measurement and monitoring interface.
  • 690 V AC rated operational voltage.
  • Suitable for IT networks up to 690 V.

Advanced Generator and Distribution Protection

The Ekip G Hi-Touch LSIG electronic trip unit combines comprehensive circuit protection with advanced functions suited to generator and critical power applications. Its L, S, I and G protection stages protect against sustained overloads, selective short circuits, severe instantaneous faults and earth faults while supporting detailed electrical monitoring and system supervision.

The ABB SACE Emax 2 platform is designed for integration into modern power-management and automation architectures. Ekip electronic releases can be supported by communication and connectivity options, making this E1.2C configuration suitable for installations requiring sophisticated protection, monitoring and dependable high-current switching.

Typical Applications

  • Generator protection and power distribution systems.
  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Manufacturing and process plants.
  • Commercial buildings and infrastructure.
  • Critical power systems and power control centres.

Technical Specifications

Series SACE Emax 2 E1.2
Order code / MPN 1SDA071510R1
EAN 8015644753603
Product type Air circuit breaker (ACB)
Rated current 1600 A
Rated uninterrupted current 1600 A
Number of poles 4
Neutral pole current 100%
Performance level C
Trip unit Ekip G Hi-Touch LSIG
Trip unit type Electronic / solid-state
Protection functions L (overload), S (selective short circuit), I (instantaneous short circuit), G (earth fault)
Mounting Fixed
Terminals Front
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate breaking capacity (Icu) at 400 / 415 V AC 50 kA
Ultimate breaking capacity (Icu) at 440 V AC 50 kA
Ultimate breaking capacity (Icu) at 500 / 525 V AC 42 kA
Ultimate breaking capacity (Icu) at 690 V AC 42 kA
Service breaking capacity (Ics) at 400–440 V AC 50 kA
Service breaking capacity (Ics) at 500–690 V AC 42 kA
Ics as percentage of Icu 100%
Rated short-time withstand current (Icw) 42 kA for 1 s
Power loss 201 W
Mechanical durability 20000 cycles
Protection rating IP30
Dimensions (H × W × D) 296 × 280 × 183 mm
Net weight 16 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071510R1?

The ABB 1SDA071510R1 is a SACE Emax 2 E1.2C four-pole fixed air circuit breaker rated at 1600 A and equipped with an Ekip G Hi-Touch LSIG electronic trip unit.

What protection functions does the Ekip G Hi-Touch LSIG provide?

The trip unit provides long-time overload (L), short-time selective short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection together with advanced monitoring and generator-oriented functionality.

What is the breaking capacity of the ABB E1.2C 1600?

The breaker provides an ultimate short-circuit breaking capacity of 50 kA at 400–440 V AC and 42 kA at 500–690 V AC.

Is the ABB 1SDA071510R1 suitable for generator applications?

Yes. Its Ekip G Hi-Touch electronic release is designed for advanced protection and monitoring in generator and demanding power distribution applications.

Is the ABB 1SDA071510R1 fixed or withdrawable?

This model is a fixed-mounted Emax 2 air circuit breaker with front terminals for integration into low-voltage switchboards.

Trusted Low-Voltage Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high breaking performance, advanced electronic protection and flexible power-management capabilities to provide dependable protection for modern low-voltage distribution and generator systems.