ABB 1SDA071493R1 Emax 2 E1.2B 1600 is a fixed four-pole 1600 A air circuit breaker with front terminals and an Ekip Dip LSIG electronic trip unit for overload, short-circuit and ground-fault protection.
£5,838.28
The ABB E1.2B 1600 Ekip Dip LSIG 4p F F, order code 1SDA071493R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for protection and switching of low-voltage AC power distribution systems. As part of the ABB Emax 2 E1.2 series, this fixed four-pole circuit breaker combines a 1600 A current rating with an electronic Ekip Dip LSIG trip unit for comprehensive overload, short-circuit and earth-fault protection.
The breaker is supplied in a fixed installation configuration with front terminals and incorporates the ABB Ekip Dip LSIG solid-state release. LSIG protection provides long-time overload protection, short-time selective protection, instantaneous short-circuit protection and ground-fault protection, making the breaker suitable for critical distribution boards, switchboards and industrial power systems requiring coordinated protection.
With a rated current of 1600 A, a rated operational voltage of up to 690 V AC and an ultimate short-circuit breaking capacity of 42 kA across common industrial AC voltages up to 690 V, the E1.2B 1600 offers dependable protection for demanding electrical distribution installations. The breaker is also supplied with auxiliary contacts and open/closed position indication for integration into control and monitoring systems.
Air circuit breakers such as the ABB Emax 2 E1.2B are used at key points in low-voltage distribution networks to protect conductors, switchboards and connected equipment against damaging overloads and short circuits. Their high current ratings and configurable electronic protection functions make them particularly suitable for main incomers, feeders and distribution sections in industrial and commercial installations.
The Ekip Dip LSIG trip unit provides multiple protection functions within one electronic release. Long-time protection responds to sustained overloads, short-time and instantaneous functions protect against short-circuit currents, while ground-fault protection helps detect potentially hazardous current flowing to earth. Adjustable settings support coordination with downstream protective devices and allow the breaker to be matched to the characteristics of the electrical system.
| Series | SACE Emax 2 |
|---|---|
| Frame | E1.2B |
| ABB order code | 1SDA071493R1 |
| Product type | Air circuit breaker |
| Rated current | 1600 A |
| Number of poles | 4 |
| Trip unit | Ekip Dip LSIG |
| Release type | Solid-state electronic |
| Installation | Fixed |
| Terminal arrangement | Front terminals |
| Rated operational voltage (Ue) | up to 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Ultimate short-circuit breaking capacity (Icu) | 42 kA at 380–690 V AC |
| Frequency | 50 / 60 Hz |
| Long-time protection | Adjustable 0.4–1 × In |
| Instantaneous protection | Adjustable 1.5–15 × In |
| Ground-fault protection | Adjustable 0.1–1 × In |
| Setting method | DIP switches |
| Auxiliary contacts | 4 |
| Standard | IEC 60947-2 |
| EAN | 8015644753436 |
| Dimensions (W × H × D) | 280 × 296 × 183 mm |
| Net weight | 16 kg |
It is a 1600 A four-pole air circuit breaker used to switch and protect high-current low-voltage AC power distribution circuits in industrial, commercial and infrastructure installations.
The Ekip Dip LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection.
The E1.2B 1600 has an ultimate short-circuit breaking capacity of 42 kA at common industrial AC voltages from 380 V through 690 V.
This version is a fixed-mount circuit breaker supplied with front terminals for connection within low-voltage switchgear.
This model has four poles, allowing switching and protection of three-phase circuits including the neutral conductor.
ABB SACE Emax 2 air circuit breakers are engineered for dependable low-voltage power distribution, combining high breaking performance with advanced electronic protection and flexible integration into modern industrial switchboards.