1SDA071471R1 ABB E1.2N 1250 Ekip Dip LI 4p F F Air Circuit Breaker

1SDA071471R1 ABB E1.2N 1250 Ekip Dip LI 4p F F Air Circuit Breaker

ABB 1SDA071471R1 SACE Emax 2 E1.2N 1250 four-pole fixed air circuit breaker with front terminals, Ekip Dip LI electronic protection, 1250 A rated current and 66 kA ultimate breaking capacity at 400–440 V AC.

SKU: 1SDA071471R1MPN: 1SDA071471R1
Price
List Price £7,423.31 ex VAT
Your Price (ex VAT) Save 25%
£5,567.48 25% OFF
You save £1,855.83 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,567.48
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,567.48

Why Choose the ABB E1.2N 1250 Ekip Dip LI 4p F F Air Circuit Breaker?

The ABB E1.2N 1250 Ekip Dip LI 4p F F, order code 1SDA071471R1, is a SACE Emax 2 air circuit breaker (ACB) designed for protection, switching and isolation in demanding low-voltage power distribution systems. This fixed four-pole E1.2N breaker combines a 1250 A rated uninterrupted current with ABB's Ekip Dip LI electronic trip unit.

The Ekip Dip LI release provides long-time overload (L) and instantaneous short-circuit (I) protection. Its straightforward electronic protection architecture is well suited to applications requiring dependable overload and high-current fault protection without the additional short-time or ground-fault functions provided by LSI and LSIG releases.

The E1.2N performance level provides an ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 500–690 V AC. With a 50 kA short-time withstand current for 1 s, fixed four-pole construction and front terminals, this breaker is suited to industrial switchboards, transformer protection and high-current incoming or distribution feeders.

Key Advantages

  • High-performance 1250 A SACE Emax 2 air circuit breaker for low-voltage distribution.
  • Ekip Dip LI electronic release provides long-time overload and instantaneous short-circuit protection.
  • 66 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 50 kA ultimate short-circuit breaking capacity at 500–690 V AC.
  • 50 kA short-time withstand current for 1 s provides robust short-circuit performance.
  • Rated service short-circuit breaking capacity of 50 kA across 400–690 V AC.
  • Four-pole configuration with a neutral pole rated at 100% of Iu.
  • Fixed construction with front terminals provides practical integration into low-voltage switchboards.

Key Features

  • ABB SACE Emax 2 E1.2N series.
  • 1250 A rated uninterrupted current (Iu).
  • 4-pole configuration.
  • 100% neutral-pole current rating.
  • Fixed circuit breaker construction.
  • Front terminals.
  • Ekip Dip LI electronic trip unit.
  • Long-time (L) overload protection.
  • Instantaneous (I) short-circuit protection.
  • No integrated ground-fault protection in this LI configuration.
  • 66 kA Icu at 400–440 V AC.
  • 50 kA Icu at 500–690 V AC.
  • 50 kA Icw for 1 s and 30 kA Icw for 3 s.
  • Four change-over auxiliary contacts.
  • Suitable for IT networks up to 690 V AC.

Reliable High-Current Distribution Protection

The ABB SACE Emax 2 E1.2N combines switching, isolation and electronic protection in a compact air circuit breaker platform. Its 1250 A rated current, four-pole construction, 66 kA ultimate breaking capacity at 400–440 V AC and 50 kA short-time withstand capability for 1 s make it suitable for important incoming and distribution positions in demanding low-voltage switchboards.

The Ekip Dip LI release provides long-time overload protection together with instantaneous short-circuit protection, helping protect conductors, busbars, transformers and connected electrical equipment against sustained overcurrent and severe short-circuit conditions. The E1.2N platform also supports optional motor operation where electrically controlled breaker operation is required.

Typical Applications

  • Low-voltage electrical distribution switchboards.
  • Industrial power distribution systems.
  • Main and sub-main incoming feeders.
  • Transformer and installation protection.
  • Four-pole distribution circuits requiring neutral switching.
  • Commercial and infrastructure electrical systems.
  • Manufacturing and process facilities.
  • IT-network applications up to 690 V AC.

Technical Specifications

Series SACE Emax 2
Frame E1.2N
ABB order code 1SDA071471R1
Product type Air circuit breaker
Rated uninterrupted current (Iu) 1250 A
Rated current (In) 1250 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Number of poles 4
Neutral-pole current 100% of Iu
Short-circuit performance level N
Trip unit Ekip Dip LI
Release type Electronic
Protection functions L and I
Instantaneous short-circuit setting 1875 A minimum
Integrated earth-fault protection No
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 50 kA
Ultimate short-circuit breaking capacity (Icu) at 525 V AC 50 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 50 kA
Rated service short-circuit breaking capacity (Ics) at 400–690 V AC 50 kA
Rated service breaking capacity 100% of Icu
Short-time withstand current (Icw), 1 s 50 kA
Short-time withstand current (Icw), 3 s 30 kA
Execution Fixed
Terminal arrangement Front terminals
Main-circuit connection Bolt connection
Recommended main-circuit screw M10
Main-circuit tightening torque 45 N·m
Auxiliary contacts 4 change-over contacts
Switched-off indication Yes
Motor drive integrated No
Motor drive Optional
Degree of protection IP30
Suitable for IT networks Yes, up to 690 V AC
Electrical durability at Ue ≤ 440 V 8000 cycles
Electrical durability at Ue 500–690 V 6500 cycles
Mechanical durability 20000 cycles
Power loss 122 W
Product dimensions (W × H × D) 280 × 296 × 183 mm
Product net weight 16 kg
Standard IEC 60947-2
EAN 8015644753214
Country of origin Italy
ABB product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA071471R1?

The ABB 1SDA071471R1 is a SACE Emax 2 E1.2N 1250 Ekip Dip LI four-pole fixed air circuit breaker with front terminals, a 1250 A rated current and electronic LI protection.

What is the rated current of the ABB E1.2N 1250?

The breaker has a rated uninterrupted current of 1250 A and a rated operational voltage of up to 690 V AC.

What protection does the Ekip Dip LI trip unit provide?

The Ekip Dip LI electronic release provides long-time overload (L) and instantaneous short-circuit (I) protection. This LI version does not incorporate integrated ground-fault protection.

What is the breaking capacity of ABB 1SDA071471R1?

The E1.2N 1250 has an ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 500–690 V AC. Its short-time withstand current is 50 kA for 1 s.

Where is the ABB E1.2N 1250 Ekip Dip LI typically used?

It is typically used in industrial and commercial low-voltage switchboards, transformer protection, incoming feeders and four-pole distribution circuits requiring dependable overload and instantaneous short-circuit protection.

Dependable Protection for Low-Voltage Distribution

ABB SACE Emax 2 air circuit breakers combine compact construction, electronic circuit protection and robust short-circuit performance, providing dependable switching and protection for industrial, commercial and infrastructure low-voltage distribution systems.