1SDA071462R1 ABB E1.2C 1250 Ekip Dip LSI 4p F F Air Circuit Breaker

1SDA071462R1 ABB E1.2C 1250 Ekip Dip LSI 4p F F Air Circuit Breaker

ABB 1SDA071462R1 Emax 2 E1.2C 1250 A four-pole fixed air circuit breaker with Ekip Dip LSI electronic protection for low-voltage power distribution systems.

SKU: 1SDA071462R1MPN: 1SDA071462R1
Price
List Price £7,142.41 ex VAT
Your Price (ex VAT) Save 25%
£5,356.81 25% OFF
You save £1,785.60 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,356.81
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,356.81

Why Choose the ABB E1.2C 1250 Ekip Dip LSI 4p F F Air Circuit Breaker?

The ABB E1.2C 1250 Ekip Dip LSI 4p F F, order code 1SDA071462R1, is a high-performance four-pole air circuit breaker (ACB) designed for protection and switching in low-voltage power distribution systems. As part of the advanced ABB Emax 2 E1.2 series, it combines a compact breaker frame with the Ekip Dip LSI electronic trip unit for dependable overload and short-circuit protection.

Rated at 1250 A, this E1.2C breaker uses a fixed installation configuration with front terminals. Its Ekip Dip LSI trip unit provides long-time overload, short-time selective short-circuit and instantaneous short-circuit protection, with protection settings conveniently configured using DIP switches.

The E1.2C performance level provides an ultimate short-circuit breaking capacity of 50 kA at 380–440 V AC and 42 kA at 500–690 V AC. With a rated operational voltage up to 690 V AC and compliance with IEC 60947-2, the breaker is well suited to industrial switchboards, distribution panels and critical electrical infrastructure.

Key Advantages

  • High-performance ABB Emax 2 air circuit breaker for low-voltage distribution.
  • 1250 A rated current for demanding power distribution applications.
  • Four-pole configuration for switching and protecting three-phase systems with neutral.
  • Ekip Dip LSI electronic trip unit provides overload and short-circuit protection.
  • Breaking capacity up to 50 kA at common industrial supply voltages.
  • Fixed-mounted construction with front terminals for switchboard integration.
  • DIP-switch trip settings provide straightforward protection configuration.
  • Designed and tested in accordance with IEC 60947-2.

Key Features

  • ABB Emax 2 E1.2C air circuit breaker.
  • 1250 A rated uninterrupted current.
  • 4-pole construction.
  • Fixed installation configuration.
  • Front terminals.
  • Ekip Dip LSI electronic protection.
  • Long-time overload protection with adjustable threshold.
  • Short-time selective and instantaneous short-circuit protection.
  • 690 V AC maximum rated operational voltage.
  • 50 / 60 Hz operating frequency.

Advanced Protection for Low-Voltage Distribution

The Ekip Dip LSI electronic trip unit provides three essential protection functions for electrical distribution networks. Long-time protection responds to sustained overload conditions, short-time protection provides selective response to high fault currents, and instantaneous protection rapidly interrupts severe short-circuit faults.

ABB Emax 2 circuit breakers are designed to combine high electrical performance with compact switchboard integration. The fixed E1.2C configuration is particularly suitable for installations where dependable protection, high breaking capacity and straightforward maintenance are required.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Manufacturing and process plants.
  • Commercial and infrastructure electrical systems.
  • Generator and transformer distribution boards.
  • Motor control and industrial distribution centres.

Technical Specifications

Series Emax 2 E1.2
Order code / MPN 1SDA071462R1
Product type Air circuit breaker (ACB)
Rated current 1250 A
Number of poles 4
Performance level C
Trip unit Ekip Dip LSI
Protection functions L (overload), S (selective short circuit), I (instantaneous short circuit)
Mounting Fixed
Terminals Front
Rated operational voltage (Ue) up to 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Ultimate breaking capacity (Icu) at 380 V AC 50 kA
Ultimate breaking capacity (Icu) at 400 / 415 V AC 50 kA
Ultimate breaking capacity (Icu) at 440 V AC 50 kA
Ultimate breaking capacity (Icu) at 500 / 525 V AC 42 kA
Ultimate breaking capacity (Icu) at 690 V AC 42 kA
Frequency 50 / 60 Hz
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071462R1?

The ABB 1SDA071462R1 is an Emax 2 E1.2C four-pole fixed air circuit breaker rated at 1250 A and equipped with an Ekip Dip LSI electronic trip unit.

What protection functions does the Ekip Dip LSI trip unit provide?

The Ekip Dip LSI provides long-time overload (L), short-time selective short-circuit (S) and instantaneous short-circuit (I) protection.

What is the breaking capacity of the E1.2C 1250 breaker?

Its ultimate short-circuit breaking capacity is 50 kA at 380–440 V AC and 42 kA at 500–690 V AC.

Is the ABB 1SDA071462R1 fixed or withdrawable?

This model is a fixed-mounted Emax 2 air circuit breaker and is supplied with front terminals.

Where is this air circuit breaker typically used?

It is designed for low-voltage power distribution applications including industrial switchboards, main distribution panels, manufacturing facilities and commercial electrical infrastructure.

Trusted Low-Voltage Protection from ABB

ABB Emax 2 air circuit breakers provide dependable protection and switching for demanding low-voltage electrical distribution systems, combining high breaking performance, electronic protection and flexible switchboard integration.