1SDA071460R1 ABB E1.2B 1250 Ekip G Hi-Touch LSIG 4p F F Air Circuit Breaker 1250 A

1SDA071460R1 ABB E1.2B 1250 Ekip G Hi-Touch LSIG 4p F F Air Circuit Breaker 1250 A

ABB 1SDA071460R1 Emax 2 E1.2B 1250 Ekip G Hi-Touch LSIG four-pole fixed air circuit breaker with front terminals, a 1250 A rated current, advanced generator and earth-fault protection and 42 kA ultimate short-circuit breaking capacity at 440 V AC.

SKU: 1SDA071460R1MPN: 1SDA071460R1
Price
List Price £11,455.92 ex VAT
Your Price (ex VAT) Save 25%
£8,591.94 25% OFF
You save £2,863.98 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,591.94
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,591.94

Why Choose the ABB E1.2B 1250 Ekip G Hi-Touch LSIG 4p F F Air Circuit Breaker?

The ABB E1.2B 1250 Ekip G Hi-Touch LSIG 4p F F, order code 1SDA071460R1, is an advanced four-pole air circuit breaker (ACB) designed for generator and low-voltage power distribution protection. Part of the ABB SACE Emax 2 series, this fixed circuit breaker combines a 1250 A rated current, dependable short-circuit performance and the sophisticated Ekip G Hi-Touch LSIG electronic protection release.

The integrated Ekip G Hi-Touch LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection together with advanced functions intended for generator applications. The Hi-Touch platform also supports sophisticated measurement, monitoring and power-quality analysis, helping operators supervise electrical conditions as well as configure protection characteristics.

The E1.2B performance level provides an ultimate short-circuit breaking capacity of 42 kA at 440 V AC and a rated short-time withstand current of 42 kA for 1 s. This version features a four-pole fixed configuration with front terminals, making it suitable for generator switchboards and three-phase four-wire low-voltage power distribution assemblies.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker for generator and low-voltage distribution protection.
  • 1250 A rated current for substantial industrial and infrastructure electrical loads.
  • 42 kA Icu at 440 V AC for dependable short-circuit interruption.
  • 42 kA Icw for 1 s supports selective protection and short-time current withstand.
  • Ekip G Hi-Touch LSIG electronic protection release with generator-oriented functionality.
  • Long-time, short-time, instantaneous and earth-fault protection provides comprehensive fault coverage.
  • Advanced measurement, monitoring and power-quality functionality supports detailed electrical supervision.
  • Four-pole fixed construction with front terminals simplifies integration into compatible switchboards.

Key Features

  • ABB SACE Emax 2 E1.2B series.
  • 1250 A rated current.
  • 42 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 42 kA rated short-time withstand current for 1 s.
  • Ekip G Hi-Touch LSIG advanced electronic protection release.
  • Long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection.
  • Dedicated protection functionality for generator applications.
  • Advanced electrical measurement and monitoring capabilities.
  • Power-quality and network analysis functionality associated with the Hi-Touch platform.
  • Four-pole construction for three-phase systems with a neutral conductor.
  • Fixed breaker construction.
  • Front main circuit terminals.

Advanced Generator and Power Distribution Protection

Generator installations can require protection characteristics beyond those used in conventional utility-fed distribution networks. The ABB Emax 2 E1.2B with Ekip G Hi-Touch combines circuit interruption, configurable electronic protection and generator-oriented functionality in a single air circuit breaker, helping protect generators, switchboards, busbars, cables and connected electrical equipment.

The Ekip G Hi-Touch LSIG release combines long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection with advanced generator protection, measurement and monitoring capabilities. This combination makes the breaker well suited to generating installations where dependable fault interruption, selective coordination and detailed supervision of electrical system performance are required.

Typical Applications

  • Generator output and generator protection switchboards.
  • Standby and emergency generating systems.
  • Low-voltage main and sub-distribution switchboards.
  • Industrial power generation and distribution systems.
  • Critical power and infrastructure installations.
  • Three-phase four-wire generator distribution networks.
  • Manufacturing and process industry power systems.
  • Power distribution systems requiring advanced generator-oriented LSIG protection and monitoring.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA071460R1
EAN 8015644753108
Product type Air circuit breaker
Frame / sub-type E1.2
Performance level B
Rated current 1250 A
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 42 kA
Rated short-time withstand current (Icw) for 1 s 42 kA
Number of poles 4P
Current type AC
Trip unit Ekip G Hi-Touch LSIG electronic release
Protection functions Long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G)
Earth-fault protection Yes
Generator-specific protection Yes
Advanced measurement and monitoring Yes
Mounting type Fixed
Terminal type Front terminals
Configuration Fixed breaker with front connections
Net weight 18 kg

Frequently Asked Questions

What is the ABB 1SDA071460R1 used for?

The ABB 1SDA071460R1 is a four-pole air circuit breaker designed for generator and low-voltage distribution applications requiring advanced electronic overload, short-circuit, earth-fault and generator-oriented protection.

What is the rated current of the ABB E1.2B 1250?

This Emax 2 air circuit breaker has a rated current of 1250 A, making it suitable for substantial industrial, infrastructure and generator distribution loads.

What is the short-circuit performance of the ABB 1SDA071460R1?

The E1.2B 1250 has an ultimate short-circuit breaking capacity of 42 kA at 440 V AC and a rated short-time withstand current of 42 kA for 1 s.

What protection functions does the Ekip G Hi-Touch LSIG release provide?

The Ekip G Hi-Touch LSIG electronic release provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection together with advanced generator-oriented protection, measurement and monitoring functionality.

Is the ABB 1SDA071460R1 fixed or withdrawable?

The 1SDA071460R1 is a fixed four-pole air circuit breaker with front main circuit terminals for integration into generator and low-voltage distribution switchboards.

Trusted Advanced Generator Protection

ABB SACE Emax 2 air circuit breakers with Ekip G Hi-Touch technology combine dependable interruption performance, comprehensive LSIG protection and advanced generator-oriented functionality for demanding generator and low-voltage power distribution systems.