ABB 1SDA071453R1 is a SACE Emax 2 E1.2B 1250 A fixed four-pole air circuit breaker with front terminals and an Ekip Dip LSIG electronic trip unit for comprehensive low-voltage distribution protection.
£5,642.69
The ABB E1.2B 1250 Ekip Dip LSIG 4p F F, order code 1SDA071453R1, is a compact SACE Emax 2 air circuit breaker (ACB) designed for comprehensive protection and switching in low-voltage electrical distribution systems. This fixed four-pole E1.2B breaker combines a 1250 A rated uninterrupted current with ABB's Ekip Dip LSIG electronic trip unit.
The Ekip Dip LSIG release provides adjustable long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection. Protection thresholds are configured through DIP switches, providing straightforward commissioning while supporting selective coordination and comprehensive fault protection throughout the electrical distribution system.
The E1.2B performance level provides an ultimate short-circuit breaking capacity of 42 kA across 380–690 V AC, with service breaking capacity equal to 100% of Icu. Its fixed four-pole construction with front terminals makes it suitable for three-phase four-wire systems requiring neutral switching and integrated earth-fault protection.
The ABB Ekip Dip LSIG trip unit combines four principal electronic protection functions. Long-time protection responds to sustained overloads, short-time protection supports selective coordination, instantaneous protection provides rapid response to severe short circuits, and earth-fault protection provides additional protection against current flowing to earth.
Protection thresholds can be configured using DIP switches, with long-time adjustment from 0.4–1 × In, short-time adjustment from 0.6–10 × In, instantaneous adjustment from 1.5–15 × In and earth-fault adjustment from 0.1–1 × In. Combined with the E1.2B frame's 42 kA breaking capacity, four-pole switching and fixed front-terminal construction, the 1SDA071453R1 provides comprehensive protection for demanding low-voltage distribution systems.
| Series | SACE Emax 2 E1.2 |
|---|---|
| Order code / MPN | 1SDA071453R1 |
| EAN | 8015644753030 |
| Product type | Air circuit breaker |
| Performance level | B |
| Rated uninterrupted current (Iu) | 1250 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Frequency | 50 / 60 Hz |
| Number of poles | 4 |
| Installation | Fixed |
| Main terminals | Front |
| Terminal type | Bolt |
| Trip unit | Ekip Dip LSIG |
| Release type | Electronic |
| Protection functions | Long-time, short-time, instantaneous and earth fault |
| Overload protection adjustment | 0.4–1 × In |
| Short-time protection adjustment | 0.6–10 × In |
| Instantaneous protection adjustment | 1.5–15 × In |
| Earth-fault protection adjustment | 0.1–1 × In |
| Protection adjustment method | DIP switches |
| Ultimate breaking capacity (Icu) at 380 V AC | 42 kA |
| Ultimate breaking capacity (Icu) at 400/415 V AC | 42 kA |
| Ultimate breaking capacity (Icu) at 440 V AC | 42 kA |
| Ultimate breaking capacity (Icu) at 500/525 V AC | 42 kA |
| Ultimate breaking capacity (Icu) at 690 V AC | 42 kA |
| Service breaking capacity (Ics) | 100% of Icu |
| Short-time withstand current (Icw) | 42 kA for 1 s; 24 kA for 3 s |
| Suitable for IT networks | Yes, up to 690 V |
| Auxiliary contacts | 4 |
| Breaker position indication | Open / closed |
| Product net weight | 18 kg |
| Standard | IEC 60947-2 |
It is a SACE Emax 2 air circuit breaker designed for comprehensive protection and switching of low-voltage electrical distribution systems.
The E1.2B 1250 has a rated uninterrupted current of 1250 A.
The breaker is equipped with an Ekip Dip LSIG electronic trip unit providing adjustable long-time, short-time, instantaneous and earth-fault protection.
The E1.2B configuration provides an ultimate short-circuit breaking capacity of 42 kA across 380–690 V AC and a short-time withstand current of 42 kA for 1 s.
The 1SDA071453R1 is a fixed four-pole air circuit breaker with front terminals, making it suitable for integration into three-phase four-wire low-voltage switchboards.
ABB SACE Emax 2 air circuit breakers combine dependable electronic protection, flexible selectivity and robust short-circuit performance for industrial, commercial, infrastructure and critical low-voltage power-distribution systems.