1SDA071451R1 ABB E1.2B 1250 Ekip Dip LI 4p F F Air Circuit Breaker

1SDA071451R1 ABB E1.2B 1250 Ekip Dip LI 4p F F Air Circuit Breaker

ABB 1SDA071451R1 SACE Emax 2 E1.2B 1250 four-pole fixed air circuit breaker with front terminals, Ekip Dip LI electronic protection, 1250 A rated current and 42 kA ultimate short-circuit breaking capacity.

SKU: 1SDA071451R1MPN: 1SDA071451R1
Price
List Price £6,520.45 ex VAT
Your Price (ex VAT) Save 25%
£4,890.34 25% OFF
You save £1,630.11 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,890.34
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,890.34

Why Choose the ABB E1.2B 1250 Ekip Dip LI 4p F F Air Circuit Breaker?

The ABB E1.2B 1250 Ekip Dip LI 4p F F, order code 1SDA071451R1, is a SACE Emax 2 air circuit breaker (ACB) designed for protection, switching and isolation in low-voltage power distribution systems. This fixed four-pole E1.2B breaker combines a 1250 A rated uninterrupted current with ABB's Ekip Dip LI solid-state electronic trip unit.

The Ekip Dip LI release provides adjustable long-time overload and instantaneous short-circuit protection. The long-time threshold can be set from 0.4–1 × In, while instantaneous protection is adjustable from 1.5–15 × In, with settings made through DIP switches for straightforward commissioning and protection configuration.

The E1.2B performance level provides an ultimate short-circuit breaking capacity of 42 kA from 400 to 690 V AC, with Ics equal to 100% of Icu and a 42 kA short-time withstand current for 1 s. Its fixed four-pole construction, front terminals and four auxiliary change-over contacts make it a practical solution for industrial switchboards, commercial distribution systems and high-current incoming or distribution feeders.

Key Advantages

  • Compact 1250 A SACE Emax 2 air circuit breaker for low-voltage power distribution.
  • Ekip Dip LI solid-state electronic release provides adjustable overload and instantaneous short-circuit protection.
  • 42 kA ultimate short-circuit breaking capacity from 400 to 690 V AC.
  • Service short-circuit breaking capacity is 100% of Icu.
  • 42 kA short-time withstand current for 1 s.
  • Four-pole configuration with a neutral pole rated at 100% of Iu.
  • Fixed construction with front terminals provides practical integration into low-voltage switchboards.

Key Features

  • ABB SACE Emax 2 E1.2B series.
  • 1250 A rated uninterrupted current (Iu).
  • 4-pole configuration.
  • 100% neutral-pole current rating.
  • Fixed circuit breaker construction.
  • Front terminals.
  • Ekip Dip LI solid-state electronic release.
  • Long-time (L) overload protection.
  • Instantaneous (I) short-circuit protection.
  • 500–1250 A long-time overload adjustment range.
  • 1875–18750 A instantaneous short-circuit adjustment range.
  • Protection settings configured using DIP switches.
  • 42 kA Icu at 400–690 V AC.
  • Four change-over auxiliary contacts.
  • Circuit-breaker open/closed position indication.

Reliable Overload and Short-Circuit Protection

The ABB SACE Emax 2 E1.2B combines switching, isolation and electronic protection in a compact air circuit breaker platform. Its 1250 A rated current, four-pole configuration, 42 kA ultimate breaking capacity and 42 kA short-time withstand capability for 1 s make it suitable for important incoming and distribution positions within low-voltage switchboards.

The Ekip Dip LI release provides adjustable long-time overload protection together with instantaneous short-circuit protection. This combination helps protect conductors, busbars and connected equipment against sustained overcurrents and severe short circuits, while DIP-switch adjustment provides a straightforward method for configuring the protection thresholds during commissioning.

Typical Applications

  • Low-voltage electrical distribution switchboards.
  • Industrial power distribution systems.
  • Main and sub-main incoming feeders.
  • Four-pole distribution circuits requiring neutral switching.
  • Transformer secondary and installation protection.
  • Commercial and infrastructure electrical systems.
  • Manufacturing and process facilities.
  • Switchboards requiring a fixed 1250 A ACB with adjustable LI protection.

Technical Specifications

Series SACE Emax 2
Frame E1.2B
ABB order code 1SDA071451R1
Product type Air circuit breaker
Rated uninterrupted current (Iu) 1250 A
Rated current (In) 1250 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Frequency 50/60 Hz
Number of poles 4
Neutral-pole current 100% of Iu
Short-circuit performance level B
Trip unit Ekip Dip LI
Release type Solid-state electronic release
Protection functions L and I
Long-time overload adjustment 0.4–1 × In / 500–1250 A
Instantaneous short-circuit adjustment 1.5–15 × In / 1875–18750 A
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 42 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 42 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 42 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 42 kA
Ultimate short-circuit breaking capacity (Icu) at 525 V AC 42 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 42 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Short-time withstand current (Icw), 1 s 42 kA
Short-time withstand current (Icw), 3 s 24 kA
Integrated earth-fault protection No
Execution Fixed
Terminal arrangement Front terminals
Main-circuit connection Bolt connection
Auxiliary contacts 4 change-over contacts
Circuit-breaker open/closed indication Yes
Motor drive integrated No
Motor drive Optional
Degree of protection IP30
Power loss 122 W
Maximum operating frequency 60 cycles per hour
Standard IEC 60947-2
EAN 8015644753016
ABB product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA071451R1?

The ABB 1SDA071451R1 is a SACE Emax 2 E1.2B 1250 Ekip Dip LI four-pole fixed air circuit breaker with front terminals, a 1250 A rated current and adjustable electronic LI protection.

What is the rated current of the ABB E1.2B 1250?

The breaker has a rated uninterrupted current of 1250 A, with adjustable long-time overload protection from 500–1250 A.

What protection does the Ekip Dip LI trip unit provide?

The Ekip Dip LI electronic release provides long-time overload (L) and instantaneous short-circuit (I) protection. The long-time threshold is adjustable from 0.4–1 × In and the instantaneous threshold from 1.5–15 × In.

What is the breaking capacity of ABB 1SDA071451R1?

The E1.2B 1250 has an ultimate short-circuit breaking capacity of 42 kA from 400 to 690 V AC. Its service breaking capacity is 100% of Icu, and its short-time withstand current is 42 kA for 1 s.

Where is the ABB E1.2B 1250 Ekip Dip LI typically used?

It is typically used in low-voltage distribution boards, industrial switchboards, incoming feeders and four-pole distribution circuits requiring dependable overload and instantaneous short-circuit protection.

Dependable Protection for Low-Voltage Distribution

ABB SACE Emax 2 air circuit breakers combine compact construction, adjustable electronic protection and dependable switching performance, providing a flexible solution for industrial, commercial and infrastructure low-voltage distribution systems.