1SDA071440R1 ABB E1.2N 1000 Ekip G Hi-Touch LSIG 4p F F Air Circuit Breaker

1SDA071440R1 ABB E1.2N 1000 Ekip G Hi-Touch LSIG 4p F F Air Circuit Breaker

ABB 1SDA071440R1 SACE Emax 2 E1.2N 1000 four-pole fixed air circuit breaker with front terminals, Ekip G Hi-Touch LSIG protection, 1000 A rated current and 66 kA ultimate breaking capacity at 400–440 V AC.

SKU: 1SDA071440R1MPN: 1SDA071440R1
Price
List Price £12,479.12 ex VAT
Your Price (ex VAT) Save 25%
£9,359.34 25% OFF
You save £3,119.78 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,359.34
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,359.34

Why Choose the ABB E1.2N 1000 Ekip G Hi-Touch LSIG 4p F F Air Circuit Breaker?

The ABB E1.2N 1000 Ekip G Hi-Touch LSIG 4p F F, order code 1SDA071440R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for advanced protection, switching and power management in low-voltage distribution and generator systems. This fixed four-pole E1.2N breaker combines a 1000 A rated uninterrupted current with ABB's sophisticated Ekip G Hi-Touch LSIG electronic trip unit.

The Ekip G Hi-Touch LSIG release provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and ground-fault protection. Its generator-oriented Hi-Touch platform adds advanced protection, measurement and power-management capabilities, making this configuration particularly suitable for generator installations and critical electrical distribution systems.

The E1.2N performance level provides an ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 500–690 V AC. The fixed four-pole construction uses front terminals and includes four change-over auxiliary contacts, providing a compact and capable solution for generator switchboards, critical incoming feeders and industrial power distribution.

Key Advantages

  • High-performance 1000 A SACE Emax 2 air circuit breaker for generator and distribution applications.
  • Ekip G Hi-Touch LSIG electronic trip unit provides comprehensive overload, short-circuit and ground-fault protection.
  • Generator-oriented protection, measurement and power-management functionality.
  • 66 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 50 kA ultimate short-circuit breaking capacity at 500–690 V AC.
  • Four-pole fixed construction with front terminals for straightforward switchboard integration.
  • Four change-over auxiliary contacts and switched-off indication support control and status monitoring.

Key Features

  • ABB SACE Emax 2 E1.2N series.
  • 1000 A rated uninterrupted current (Iu).
  • 4-pole configuration.
  • Fixed circuit breaker construction.
  • Front terminals.
  • Ekip G Hi-Touch LSIG electronic release.
  • Long-time (L) overload protection.
  • Short-time (S) selective short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Ground-fault (G) protection.
  • 400–1000 A long-time overload adjustment range.
  • 600–10000 A short-time protection adjustment range.
  • 1500–15000 A instantaneous protection adjustment range.
  • 100–1000 A ground-fault protection adjustment range.
  • 66 kA Icu at 400–440 V AC.
  • 50 kA Icu at 500–690 V AC.

Advanced Generator and Power Distribution Protection

The ABB SACE Emax 2 E1.2N combines switching, isolation and advanced electronic protection in a compact air circuit breaker platform. Its 1000 A rated current, four-pole configuration and 66 kA ultimate breaking capacity at 400–440 V AC provide robust fault-interruption capability for demanding generator and low-voltage distribution systems.

The Ekip G Hi-Touch LSIG release combines adjustable long-time, short-time, instantaneous and ground-fault protection with generator-oriented protection and advanced electrical supervision. This comprehensive functionality supports selective fault coordination and dependable protection of generators, conductors, busbars and connected equipment in critical power systems.

Typical Applications

  • Generator protection and generator switchboards.
  • Standby and emergency power systems.
  • Low-voltage electrical distribution switchboards.
  • Industrial power distribution systems.
  • Main and sub-main incoming feeders.
  • Four-pole distribution circuits requiring four-conductor switching.
  • Manufacturing, process and infrastructure facilities.
  • Critical installations requiring advanced LSIG protection, measurement and power-management capabilities.

Technical Specifications

Series SACE Emax 2
Frame E1.2N
ABB order code 1SDA071440R1
Product type Air circuit breaker
Rated uninterrupted current (Iu) 1000 A
Rated current (In) 1000 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50/60 Hz
Number of poles 4
Short-circuit performance level N
Trip unit Ekip G Hi-Touch LSIG
Release type Solid-state electronic release
Protection functions L, S, I and G
Long-time overload adjustment 0.4–1 × In / 400–1000 A
Short-time protection adjustment 0.6–10 × In / 600–10000 A
Instantaneous protection adjustment 1.5–15 × In / 1500–15000 A
Ground-fault protection adjustment 0.1–1 × In / 100–1000 A
Ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 500/525 V AC 50 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 50 kA
Integrated earth-fault protection Yes
Execution Fixed
Terminal arrangement Front terminals
Main-circuit connection Bolt connection
Auxiliary contacts 4 change-over contacts
Switched-off indication Yes
Integrated undervoltage release No
Motor drive integrated No
Motor drive Optional
Degree of protection IP30
Net weight 11 kg
Country of origin Italy
ABB product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA071440R1?

The ABB 1SDA071440R1 is a SACE Emax 2 E1.2N 1000 Ekip G Hi-Touch LSIG four-pole fixed air circuit breaker with front terminals, a 1000 A rated current and advanced generator-oriented electronic protection.

What is the rated current of the ABB E1.2N 1000?

The breaker has a rated uninterrupted current of 1000 A, with adjustable long-time overload protection from 400–1000 A.

What protection does the Ekip G Hi-Touch LSIG trip unit provide?

The Ekip G Hi-Touch LSIG electronic trip unit provides long-time overload (L), short-time delayed short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection together with generator-oriented protection, measurement and power-management functionality.

What is the breaking capacity of ABB 1SDA071440R1?

The E1.2N 1000 has an ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 500–690 V AC.

Where is the ABB E1.2N 1000 Ekip G Hi-Touch LSIG typically used?

It is typically used in generator switchboards, standby power systems, industrial low-voltage distribution boards, critical incoming feeders and four-pole circuits requiring comprehensive LSIG protection and advanced electrical supervision.

Advanced Protection for Generator and Distribution Systems

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, measurement and power-management capabilities with high short-circuit performance, providing comprehensive protection for generator installations and critical low-voltage distribution systems.