ABB 1SDA071418R1 is a SACE Emax 2 E1.2B 1000 A fixed four-pole air circuit breaker with front terminals and an Ekip Hi-Touch LSI electronic trip unit for advanced protection, measurement and monitoring in low-voltage power distribution systems.
£7,448.36
The ABB 1SDA071418R1 is a high-performance SACE Emax 2 E1.2B air circuit breaker designed for advanced protection, measurement and switching in low-voltage power distribution systems. Rated at 1000 A, this four-pole fixed breaker combines ABB's compact E1.2B frame with the advanced Ekip Hi-Touch LSI electronic trip unit.
The Ekip Hi-Touch LSI release provides long-time overload (L), short-time selective short-circuit (S) and instantaneous short-circuit (I) protection. Integrated Ekip Measuring Pro and Network Analyzer functionality adds advanced electrical measurement and power-quality analysis, while the touch-sensitive display provides an intuitive interface for configuration and system supervision.
The 1SDA071418R1 is supplied in a fixed four-pole configuration with front terminals. With a rated operational voltage of up to 690 V AC, a rated insulation voltage of 1000 V AC and an ultimate short-circuit breaking capacity of 42 kA at 380–690 V AC, it provides dependable protection for industrial, commercial and infrastructure power distribution systems.
The ABB SACE Emax 2 E1.2B platform provides switching, isolation and electronic fault protection for low-voltage electrical distribution networks. Its compact construction and 42 kA short-circuit performance across a broad operating-voltage range make it suitable for switchboards where dependable protection, selective coordination and efficient use of installation space are important.
The Ekip Hi-Touch LSI electronic release combines adjustable overload, short-time and instantaneous protection with advanced electrical measurement. Integrated Ekip Measuring Pro and Network Analyzer functionality makes the 1SDA071418R1 particularly suitable for installations where circuit protection, energy-system visibility and power-quality supervision are required from a single integrated breaker platform.
| Series | SACE Emax 2 |
|---|---|
| Frame | E1.2B |
| ABB order code | 1SDA071418R1 |
| EAN | 8015644752682 |
| Product type | Air circuit breaker |
| Rated current (In) | 1000 A |
| Number of poles | 4 |
| Neutral pole current | 100% of rated current |
| Installation | Fixed |
| Main terminal arrangement | Front terminals |
| Main circuit connection | Bolt connection |
| Trip unit | Ekip Hi-Touch LSI |
| Release type | Electronic / solid-state |
| Protection functions | Long-time (L), short-time (S), instantaneous (I) |
| Overload protection adjustment | 0.4–1 × In |
| Short-time selective protection adjustment | 0.6–10 × In |
| Instantaneous protection adjustment | 1.5–15 × In |
| Integrated earth-fault protection | No |
| Measurement | Ekip Measuring Pro |
| Power-quality analysis | Network Analyzer |
| Current type | AC |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Frequency | 50 / 60 Hz |
| Ultimate short-circuit breaking capacity (Icu) at 380 V AC | 42 kA |
| Ultimate short-circuit breaking capacity (Icu) at 400/415 V AC | 42 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 42 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500/525 V AC | 42 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 42 kA |
| Rated short-time withstand current (Icw) at 1 s | 42 kA |
| Electrical durability at ≤440 V | 8000 cycles |
| Electrical durability at 500–690 V | 8000 cycles |
| Mechanical durability | 20000 cycles |
| Power loss | 78 W |
| Auxiliary contacts | 4 change-over contacts |
| Breaker position indication | Open / closed |
| Standard | IEC 60947-2 |
The ABB 1SDA071418R1 is a SACE Emax 2 E1.2B 1000 A four-pole fixed air circuit breaker with front terminals and an Ekip Hi-Touch LSI electronic protection release.
The circuit breaker has a rated current of 1000 A, making it suitable for substantial low-voltage incomer, feeder and power distribution applications.
The Ekip Hi-Touch LSI release provides long-time overload protection (L), short-time selective short-circuit protection (S) and instantaneous short-circuit protection (I).
The E1.2B 1000 has an ultimate short-circuit breaking capacity of 42 kA at 380, 400/415, 440, 500/525 and 690 V AC.
Yes. The Ekip Hi-Touch configuration incorporates Ekip Measuring Pro and Network Analyzer functionality for advanced electrical measurement and power-quality analysis.
This model is a fixed four-pole air circuit breaker with front terminals, designed for permanent installation within a suitable low-voltage switchboard or power distribution assembly.