1SDA071415R1 ABB E1.2B 1000 Ekip Touch LSI 4p F F Air Circuit Breaker

1SDA071415R1 ABB E1.2B 1000 Ekip Touch LSI 4p F F Air Circuit Breaker

ABB 1SDA071415R1 is a SACE Emax 2 E1.2B 1000 A fixed four-pole air circuit breaker with front terminals and an Ekip Touch LSI electronic trip unit for selective low-voltage distribution protection.

SKU: 1SDA071415R1MPN: 1SDA071415R1
Price
List Price £6,600.67 ex VAT
Your Price (ex VAT) Save 25%
£4,950.50 25% OFF
You save £1,650.17 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,950.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,950.50

Why Choose the ABB E1.2B 1000 Ekip Touch LSI 4p F F Air Circuit Breaker?

The ABB E1.2B 1000 Ekip Touch LSI 4p F F, order code 1SDA071415R1, is a compact SACE Emax 2 air circuit breaker (ACB) designed for protection, switching and monitoring in low-voltage electrical distribution systems. This fixed four-pole E1.2B breaker combines a 1000 A rated uninterrupted current with ABB's Ekip Touch LSI electronic trip unit.

The Ekip Touch LSI release provides adjustable long-time overload, short-time selective short-circuit and instantaneous short-circuit protection. Its touchscreen interface gives convenient access to protection settings and operating information, while the short-time protection function supports selective coordination between upstream and downstream protective devices.

The E1.2B performance level provides an ultimate short-circuit breaking capacity of 42 kA across 380–690 V AC and a short-time withstand current of 42 kA for 1 s. Its fixed four-pole construction with front terminals makes it suitable for three-phase four-wire systems requiring neutral switching and advanced selective circuit protection.

Key Advantages

  • Compact ABB SACE Emax 2 E1.2B air circuit breaker.
  • 1000 A rated uninterrupted current for low-voltage power distribution.
  • 42 kA ultimate short-circuit breaking capacity across 380–690 V AC.
  • Advanced Ekip Touch LSI electronic trip unit.
  • LSI protection provides long-time, short-time and instantaneous protection.
  • Short-time protection supports selective coordination throughout the distribution system.
  • Four-pole configuration supports switching of three phases and neutral.
  • Fixed construction with front terminals supports straightforward switchboard integration.

Key Features

  • ABB SACE Emax 2 E1.2B series.
  • 1000 A rated uninterrupted current.
  • Four-pole fixed configuration.
  • Ekip Touch LSI electronic protection release.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 50/60 Hz operating frequency.
  • 42 kA Icu across 380–690 V AC.
  • 42 kA short-time withstand current for 1 s.
  • Adjustable long-time overload protection.
  • Adjustable short-time selective short-circuit protection.
  • Adjustable instantaneous short-circuit protection.
  • Front main terminals for fixed switchboard installation.

Advanced Touchscreen LSI Protection

The ABB Ekip Touch LSI trip unit combines long-time overload protection with short-time selective and instantaneous short-circuit protection. Long-time protection can be adjusted from 0.4–1 × In, short-time protection from 0.6–10 × In and instantaneous protection from 1.5–15 × In, providing flexibility when coordinating protection across a low-voltage distribution system.

The touchscreen interface simplifies configuration and access to operating information, while the E1.2B frame delivers 42 kA ultimate breaking capacity throughout its specified 380–690 V AC range. Combined with four-pole switching and fixed front-terminal construction, the 1SDA071415R1 provides a capable solution for industrial, commercial and infrastructure distribution switchboards.

Typical Applications

  • Low-voltage power distribution switchboards.
  • Main incoming and feeder circuit protection.
  • Industrial manufacturing and process facilities.
  • Commercial building electrical distribution.
  • Infrastructure and utility installations.
  • Data centres and critical power systems.
  • Three-phase four-wire networks requiring neutral switching and selective protection.

Technical Specifications

Series SACE Emax 2 E1.2
Order code / MPN 1SDA071415R1
EAN 8015644752651
Product type Air circuit breaker
Performance level B
Rated uninterrupted current (Iu) 1000 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50 / 60 Hz
Number of poles 4
Installation Fixed
Main terminals Front
Trip unit Ekip Touch LSI
Release type Electronic
Protection functions Long-time, short-time and instantaneous
Overload protection adjustment 0.4–1 × In
Short-time protection adjustment 0.6–10 × In
Instantaneous protection adjustment 1.5–15 × In
Ultimate breaking capacity (Icu) at 380 V AC 42 kA
Ultimate breaking capacity (Icu) at 400/415 V AC 42 kA
Ultimate breaking capacity (Icu) at 440 V AC 42 kA
Ultimate breaking capacity (Icu) at 500/525 V AC 42 kA
Ultimate breaking capacity (Icu) at 690 V AC 42 kA
Short-time withstand current (Icw) 42 kA for 1 s
Integrated earth-fault protection No
Auxiliary contacts 4
Breaker position indication Open / closed
Degree of protection IP30
Power loss 78 W
Mechanical durability 20000 cycles
Electrical durability 8000 cycles
Product net width 284 mm
Product net height 295 mm
Product net depth 184 mm
Product net weight 14 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071415R1 used for?

It is a SACE Emax 2 air circuit breaker designed for protection, switching and selective coordination in low-voltage electrical distribution systems.

What is the current rating of this circuit breaker?

The E1.2B 1000 has a rated uninterrupted current of 1000 A.

Which protection unit is fitted to the 1SDA071415R1?

The breaker is equipped with an Ekip Touch LSI electronic trip unit providing adjustable long-time, short-time and instantaneous protection.

What is the breaking capacity of the ABB E1.2B 1000?

The E1.2B configuration provides an ultimate short-circuit breaking capacity of 42 kA across 380–690 V AC.

How is the ABB 1SDA071415R1 installed?

The 1SDA071415R1 is a fixed four-pole air circuit breaker with front terminals, making it suitable for integration into three-phase four-wire low-voltage switchboards.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, flexible selectivity and dependable short-circuit performance for industrial, commercial, infrastructure and critical low-voltage power-distribution systems.