ABB 1SDA071400R1 SACE Emax 2 E1.2N 800 four-pole fixed air circuit breaker with front terminals, Ekip G Hi-Touch LSIG protection, 800 A rated current and 66 kA ultimate breaking capacity at 400–440 V AC.
£9,254.00
The ABB E1.2N 800 Ekip G Hi-Touch LSIG 4p F F, order code 1SDA071400R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for advanced protection and management of low-voltage distribution and generator systems. This fixed four-pole E1.2N breaker combines an 800 A rated uninterrupted current with ABB's sophisticated Ekip G Hi-Touch LSIG electronic trip unit.
The Ekip G Hi-Touch LSIG release provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection together with advanced generator-oriented protection, measurement and power-management capabilities. The Hi-Touch platform is intended for applications requiring comprehensive electrical supervision and sophisticated protection coordination.
The E1.2N performance level provides an ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 690 V AC. Its 50 kA short-time withstand current for 1 s, four-pole fixed construction and front terminals make it a capable solution for generator switchboards, critical incoming feeders and industrial low-voltage distribution systems.
The ABB SACE Emax 2 E1.2N combines switching, isolation and sophisticated electronic protection in a compact air circuit breaker platform. Its 800 A rated current, four-pole construction, 66 kA ultimate breaking capacity at 400–440 V AC and 50 kA short-time withstand capability for 1 s make it suitable for critical positions within generator and low-voltage distribution switchboards.
The Ekip G Hi-Touch LSIG release combines adjustable long-time, short-time, instantaneous and ground-fault protection with the enhanced generator, measurement and power-management capabilities of ABB's Hi-Touch platform. This comprehensive functionality supports selective fault coordination, detailed electrical supervision and dependable protection of generators, conductors, busbars and connected equipment.
| Series | SACE Emax 2 |
|---|---|
| Frame | E1.2N |
| ABB order code | 1SDA071400R1 |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 800 A |
| Rated current (In) | 800 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Number of poles | 4 |
| Neutral-pole current | 100% of Iu |
| Short-circuit performance level | N |
| Trip unit | Ekip G Hi-Touch LSIG |
| Release type | Electronic |
| Protection functions | L, S, I and G |
| Overload release adjustment | 320–800 A |
| Short-time delayed short-circuit adjustment | 480–8000 A |
| Instantaneous short-circuit adjustment | 1200–12000 A |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500 V AC | 50 kA |
| Ultimate short-circuit breaking capacity (Icu) at 525 V AC | 50 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 50 kA |
| Service short-circuit breaking capacity (Ics) at 400 V AC | 50 kA |
| Service short-circuit breaking capacity (Ics) at 415 V AC | 50 kA |
| Service short-circuit breaking capacity (Ics) at 440 V AC | 50 kA |
| Service short-circuit breaking capacity (Ics) at 500–690 V AC | 50 kA |
| Short-time withstand current (Icw), 1 s | 50 kA |
| Short-time withstand current (Icw), 3 s | 30 kA |
| Integrated ground-fault protection | Yes |
| Execution | Fixed |
| Terminal arrangement | Front terminals |
| Power loss | 50 W |
| Maximum operating frequency | 60 cycles per hour |
| Standard | IEC 60947-2 |
| Country of origin | Italy |
| ABB product group | Emax2 Air Circuit Breaker |
The ABB 1SDA071400R1 is a SACE Emax 2 E1.2N 800 Ekip G Hi-Touch LSIG four-pole fixed air circuit breaker with front terminals, an 800 A rated current and advanced generator-oriented electronic protection.
The breaker has a rated uninterrupted current of 800 A, with an adjustable long-time overload protection range of 320–800 A.
The Ekip G Hi-Touch LSIG electronic trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection together with advanced generator, measurement and power-management functionality.
The E1.2N 800 has an ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 500–690 V AC. Its short-time withstand current is 50 kA for 1 s.
It is typically used in generator switchboards, standby power systems, industrial low-voltage distribution boards, critical incoming feeders and four-pole circuits requiring comprehensive LSIG protection and advanced electrical supervision.
ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, measurement and power-management capabilities with dependable short-circuit performance, providing comprehensive protection for generator installations and critical low-voltage distribution systems.