ABB 1SDA071397R1 is a SACE Emax 2 E1.2N 800 A fixed four-pole air circuit breaker with front terminals, an Ekip G Touch LSIG electronic trip unit, generator-specific protection, 690 V AC rated operational voltage and 66 kA breaking capacity at 380–440 V AC.
£8,591.94
The ABB 1SDA071397R1 is a high-performance SACE Emax 2 E1.2N air circuit breaker (ACB) designed for advanced protection and control of low-voltage generator and electrical distribution systems. Rated at 800 A, this fixed four-pole circuit breaker combines ABB’s compact E1.2 frame with the specialised Ekip G Touch LSIG electronic trip unit for comprehensive generator and distribution protection.
As part of the advanced ABB SACE Emax 2 series, the E1.2N provides dependable circuit protection while supporting modern power-management requirements. The Ekip G Touch LSIG release provides long-time, short-time, instantaneous and ground-fault protection together with generator-specific protection functions and integrated Ekip Measuring Pro functionality, making it particularly suitable for generator installations and critical low-voltage networks.
With a rated uninterrupted current of 800 A, a rated operational voltage of 690 V AC and a rated ultimate short-circuit breaking capacity of 66 kA at 380–440 V AC, the 1SDA071397R1 delivers substantial fault-clearing performance in a compact format. This version features a fixed four-pole configuration with front terminals, providing straightforward integration into generator switchboards, industrial power systems and low-voltage distribution assemblies.
Air circuit breakers such as the ABB SACE Emax 2 E1.2N protect important low-voltage circuits against damaging overload, short-circuit and earth-fault conditions. The 1SDA071397R1 combines an 800 A continuous-current rating with high short-circuit interruption capability, making it suitable for generator protection, main incomers and critical distribution circuits within industrial and commercial switchboards.
The Ekip G Touch LSIG trip unit extends conventional LSIG circuit protection with functions specifically developed for generator applications. Its electronic architecture, integrated Ekip Measuring Pro module and touchscreen interface support precise protection configuration and electrical monitoring, helping engineers coordinate generator and distribution protection across modern low-voltage networks.
| Series | SACE Emax 2 |
|---|---|
| Frame / sub-type | E1.2N |
| Order code / MPN | 1SDA071397R1 |
| Product type | Air circuit breaker |
| Short-circuit performance level | N |
| Rated current (In) | 800 A |
| Rated uninterrupted current (Iu) | 800 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Frequency | 50 / 60 Hz |
| Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC | 66 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC | 66 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 66 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC | 50 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 50 kA |
| Number of poles | 4 |
| Trip unit | Ekip G Touch LSIG |
| Release type | Electronic |
| Protection functions | LSIG |
| Overload protection adjustment | 0.4–1 × In |
| Overload protection adjustment range | 320–800 A |
| Short-time protection adjustment | 0.6–10 × In |
| Short-time protection adjustment range | 480–8000 A |
| Instantaneous protection adjustment | 1.5–15 × In |
| Instantaneous protection adjustment range | 1200–12,000 A |
| Ground-fault protection adjustment | 0.1–1 × In |
| Integrated earth-fault protection | Yes |
| Generator-specific protection | Yes |
| Measurement module | Ekip Measuring Pro |
| Current type | AC |
| Installation version | Fixed |
| Terminal connection | Front |
| Optional motor operating mechanism | Yes |
| Standard | IEC 60947-2 |
The ABB 1SDA071397R1 is an 800 A Emax 2 air circuit breaker designed for protection and control of low-voltage generator and electrical distribution systems.
The circuit breaker has a rated current and rated uninterrupted current of 800 A.
The E1.2N version has a rated ultimate short-circuit breaking capacity of 66 kA at 380–440 V AC and 50 kA at 500–690 V AC.
The Ekip G Touch LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection together with specialised protection functions for generator applications.
The 1SDA071397R1 is a fixed four-pole air circuit breaker with front terminals for integration into generator and low-voltage distribution switchboards.
ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, generator-specific functionality and high short-circuit performance for dependable operation in modern industrial, commercial and critical-power electrical systems.