1SDA071390R1 ABB E1.2C 800 Ekip G Hi-Touch LSIG 4p F F Air Circuit Breaker

1SDA071390R1 ABB E1.2C 800 Ekip G Hi-Touch LSIG 4p F F Air Circuit Breaker

ABB 1SDA071390R1 is a SACE Emax 2 E1.2C 800 A fixed four-pole air circuit breaker with front terminals and an Ekip G Hi-Touch LSIG electronic trip unit for advanced low-voltage distribution and generator protection.

SKU: 1SDA071390R1MPN: 1SDA071390R1
Price
List Price £11,175.03 ex VAT
Your Price (ex VAT) Save 25%
£8,381.27 25% OFF
You save £2,793.76 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,381.27
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,381.27

Why Choose the ABB E1.2C 800 Ekip G Hi-Touch LSIG 4p F F Air Circuit Breaker?

The ABB E1.2C 800 Ekip G Hi-Touch LSIG 4p F F, order code 1SDA071390R1, is an advanced SACE Emax 2 air circuit breaker (ACB) designed for protection, monitoring and control of low-voltage distribution and generator systems. This fixed four-pole E1.2C breaker combines an 800 A rated uninterrupted current with ABB's sophisticated Ekip G Hi-Touch LSIG electronic trip unit.

The Ekip G Hi-Touch LSIG release provides long-time, short-time, instantaneous and earth-fault protection together with advanced generator-oriented functionality. Its touchscreen interface, measurement capabilities and power-quality monitoring support detailed supervision of demanding electrical systems while providing comprehensive protection against overloads and electrical faults.

The E1.2C performance level provides an ultimate short-circuit breaking capacity of 50 kA at 400/415/440 V AC and 42 kA at 500/525/690 V AC. Its fixed four-pole construction with front terminals is suitable for three-phase four-wire systems requiring neutral switching, advanced generator protection and integrated earth-fault protection.

Key Advantages

  • Compact ABB SACE Emax 2 E1.2C air circuit breaker.
  • 800 A rated uninterrupted current for low-voltage power distribution.
  • 50 kA ultimate short-circuit breaking capacity at 400/415/440 V AC.
  • Advanced Ekip G Hi-Touch LSIG electronic trip unit for distribution and generator applications.
  • LSIG protection covers overload, selective short circuit, instantaneous short circuit and earth fault.
  • 42 kA short-time withstand current for 1 s supports selective protection strategies.
  • Four-pole configuration supports switching of three phases and neutral.
  • Fixed construction with front terminals supports straightforward switchboard integration.

Key Features

  • ABB SACE Emax 2 E1.2C series.
  • 800 A rated uninterrupted current.
  • Four-pole fixed configuration.
  • Ekip G Hi-Touch LSIG advanced electronic protection release.
  • 690 V AC rated voltage.
  • Long-time overload protection.
  • Short-time selective short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • Generator-oriented protection and monitoring functionality.
  • 50 kA Icu at 400/415/440 V AC.
  • 42 kA Icu at 500/525/690 V AC.
  • Front main terminals for fixed switchboard installation.

Advanced Generator and Distribution Protection

The ABB Ekip G Hi-Touch LSIG trip unit combines comprehensive electronic circuit protection with advanced functionality intended for generator applications. Long-time protection responds to sustained overloads, short-time protection supports selective coordination, instantaneous protection responds rapidly to severe short circuits, and earth-fault protection provides additional protection against current flowing to earth.

The Hi-Touch platform extends protection with advanced measurement and power-quality monitoring capabilities, helping operators assess electrical system performance and identify abnormal conditions. Combined with the E1.2C frame's 50 kA breaking capacity at 400/415/440 V AC, four-pole switching and front-terminal fixed construction, the 1SDA071390R1 is well suited to sophisticated generator and low-voltage distribution switchboards.

Typical Applications

  • Generator protection and generator switchboards.
  • Low-voltage power distribution switchboards.
  • Main incoming and feeder circuit protection.
  • Industrial manufacturing and process facilities.
  • Commercial building electrical distribution.
  • Infrastructure and critical power installations.
  • Three-phase four-wire networks requiring neutral switching and earth-fault protection.

Technical Specifications

Series SACE Emax 2 E1.2
Order code / MPN 1SDA071390R1
EAN 8015644752408
Product type Air circuit breaker
Performance level C
Rated uninterrupted current (Iu) 800 A
Rated voltage 690 V AC
Number of poles 4
Installation Fixed
Main terminals Front
Main circuit connection Bolt connection
Trip unit Ekip G Hi-Touch LSIG
Release type Electronic
Protection functions Long-time, short-time, instantaneous and earth fault
Ultimate breaking capacity (Icu) at 400 V AC 50 kA
Ultimate breaking capacity (Icu) at 415 V AC 50 kA
Ultimate breaking capacity (Icu) at 440 V AC 50 kA
Ultimate breaking capacity (Icu) at 500/525 V AC 42 kA
Ultimate breaking capacity (Icu) at 690 V AC 42 kA
Service breaking capacity (Ics) 100% of Icu
Short-time withstand current (Icw) 42 kA for 1 s; 24 kA for 3 s
Suitable for IT networks Yes, up to 690 V
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071390R1 used for?

It is a SACE Emax 2 air circuit breaker designed for advanced protection, monitoring and control of low-voltage distribution and generator systems.

What is the current rating of this circuit breaker?

The E1.2C 800 has a rated uninterrupted current of 800 A.

Which protection unit is fitted to the 1SDA071390R1?

The breaker is equipped with an Ekip G Hi-Touch LSIG electronic trip unit providing long-time, short-time, instantaneous and earth-fault protection together with advanced generator-oriented functionality.

What is the breaking capacity of the ABB E1.2C 800?

The E1.2C configuration provides an ultimate short-circuit breaking capacity of 50 kA at 400/415/440 V AC and 42 kA at 690 V AC.

How is the ABB 1SDA071390R1 installed?

The 1SDA071390R1 is a fixed four-pole air circuit breaker with front terminals, making it suitable for integration into three-phase four-wire low-voltage and generator switchboards.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, sophisticated monitoring and dependable short-circuit performance for industrial, commercial, infrastructure and power-generation electrical systems.