1SDA071387R1 ABB E1.2C 800 Ekip G Touch LSIG 4p F F Air Circuit Breaker

1SDA071387R1 ABB E1.2C 800 Ekip G Touch LSIG 4p F F Air Circuit Breaker

ABB 1SDA071387R1 SACE Emax 2 E1.2C 800 four-pole fixed air circuit breaker with front terminals, Ekip G Touch LSIG generator protection, 800 A rated current and 50 kA ultimate breaking capacity at 400–440 V AC.

SKU: 1SDA071387R1MPN: 1SDA071387R1
Price
List Price £10,352.45 ex VAT
Your Price (ex VAT) Save 25%
£7,764.34 25% OFF
You save £2,588.11 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,764.34
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,764.34

Why Choose the ABB E1.2C 800 Ekip G Touch LSIG 4p F F Air Circuit Breaker?

The ABB E1.2C 800 Ekip G Touch LSIG 4p F F, order code 1SDA071387R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for protection, switching and management of low-voltage power distribution and generator circuits. This fixed four-pole E1.2C breaker combines an 800 A rated uninterrupted current with ABB's advanced Ekip G Touch LSIG electronic trip unit.

The Ekip G Touch LSIG release provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and ground-fault protection. Generator-specific protection functions and the integrated Ekip Measuring Pro module extend its capabilities for generator installations, while the touchscreen interface provides convenient configuration and access to protection and measurement functions.

The E1.2C performance level provides an ultimate short-circuit breaking capacity of 50 kA at 400–440 V AC, reducing to 42 kA at 500–690 V AC. With a 42 kA short-time withstand current for 1 s, fixed four-pole construction and front terminals, this breaker is suited to generator switchboards, industrial distribution systems and critical incoming or distribution feeders.

Key Advantages

  • Compact 800 A SACE Emax 2 air circuit breaker for low-voltage power distribution and generator applications.
  • Ekip G Touch LSIG electronic trip unit with generator-specific protection functionality.
  • Long-time, short-time, instantaneous and ground-fault protection.
  • Integrated Ekip Measuring Pro measurement functionality.
  • 50 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 42 kA short-time withstand current for 1 s supports selective protection architectures.
  • Four-pole fixed construction with front terminals for switchboard integration.

Key Features

  • ABB SACE Emax 2 E1.2C series.
  • 800 A rated uninterrupted current (Iu).
  • 4-pole configuration.
  • 100% neutral-pole current rating.
  • Fixed circuit breaker construction.
  • Front terminals.
  • Ekip G Touch LSIG solid-state electronic release.
  • Long-time (L) overload protection.
  • Short-time (S) selective short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Ground-fault (G) protection.
  • 320–800 A long-time overload adjustment range.
  • 480–8000 A short-time protection adjustment range.
  • 1200–12000 A instantaneous protection adjustment range.
  • 80–800 A ground-fault protection adjustment range.
  • Generator-specific protection functions.
  • Integrated Ekip Measuring Pro module.
  • Touch-sensitive display for protection configuration and supervision.

Advanced Generator and Distribution Protection

The ABB SACE Emax 2 E1.2C combines switching, isolation, measurement and advanced electronic protection in a compact air circuit breaker platform. Its 800 A rated current, four-pole construction and 50 kA breaking capacity at 400–440 V AC make it suitable for important incoming and distribution positions as well as generator switchboards where dependable fault interruption is essential.

The Ekip G Touch LSIG release combines adjustable long-time, short-time, instantaneous and ground-fault protection with generator-specific functions and integrated Ekip Measuring Pro capabilities. This comprehensive protection architecture supports coordinated fault clearance, system supervision and reliable protection of generators, conductors, busbars and connected electrical equipment.

Typical Applications

  • Generator protection and generator switchboards.
  • Standby and emergency power systems.
  • Low-voltage electrical distribution switchboards.
  • Industrial power distribution systems.
  • Main and sub-main incoming feeders.
  • Four-pole distribution circuits requiring neutral switching.
  • Manufacturing and process facilities.
  • Critical infrastructure requiring comprehensive LSIG protection and electrical measurement.

Technical Specifications

Series SACE Emax 2
Frame E1.2C
ABB order code 1SDA071387R1
Product type Air circuit breaker
Rated uninterrupted current (Iu) 800 A
Rated current (In) 800 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Frequency 50/60 Hz
Number of poles 4
Neutral-pole current 100% of Iu
Short-circuit performance level C
Trip unit Ekip G Touch LSIG
Release type Electronic / solid-state
Protection functions L, S, I and G
Long-time overload adjustment 0.4–1 × In / 320–800 A
Short-time protection adjustment 0.6–10 × In / 480–8000 A
Instantaneous protection adjustment 1.5–15 × In / 1200–12000 A
Ground-fault protection adjustment 0.1–1 × In / 80–800 A
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 50 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 50 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 50 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 42 kA
Ultimate short-circuit breaking capacity (Icu) at 525 V AC 42 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 42 kA
Service short-circuit breaking capacity (Ics) 100% of Icu
Short-time withstand current (Icw), 1 s 42 kA
Short-time withstand current (Icw), 3 s 24 kA
Integrated ground-fault protection Yes
Generator-specific protection Yes
Measurement module Ekip Measuring Pro
Execution Fixed
Terminal arrangement Front terminals
Suitable for IT networks Yes, up to 690 V AC
Power loss 50 W
Electrical durability 8000 operating cycles
Mechanical durability 20000 operating cycles
Dimensions (W × H × D) 280 × 296 × 183 mm
Net weight 16 kg
Standard IEC 60947-2
EAN 8015644752378
ABB product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA071387R1?

The ABB 1SDA071387R1 is a SACE Emax 2 E1.2C 800 Ekip G Touch LSIG four-pole fixed air circuit breaker with front terminals, an 800 A rated current and generator-oriented electronic protection.

What is the rated current of the ABB E1.2C 800?

The breaker has a rated uninterrupted current of 800 A, with adjustable long-time overload protection from 320–800 A.

What protection does the Ekip G Touch LSIG trip unit provide?

The Ekip G Touch LSIG electronic trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection, together with generator-specific protection functions and integrated Ekip Measuring Pro capabilities.

What is the breaking capacity of ABB 1SDA071387R1?

The E1.2C 800 has an ultimate short-circuit breaking capacity of 50 kA at 400–440 V AC and 42 kA at 500–690 V AC, with a short-time withstand current of 42 kA for 1 s.

Where is the ABB E1.2C 800 Ekip G Touch LSIG typically used?

It is typically used in generator switchboards, standby power systems, low-voltage distribution boards, industrial electrical systems and critical four-pole feeder applications requiring comprehensive LSIG protection and advanced measurement capabilities.

Advanced Protection for Generator and Distribution Systems

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, measurement and dependable short-circuit performance, providing comprehensive switching and protection for generator installations and critical low-voltage distribution systems.