1SDA071353R1 ABB E1.2N 630 Ekip Dip LSIG 4p F F Air Circuit Breaker

1SDA071353R1 ABB E1.2N 630 Ekip Dip LSIG 4p F F Air Circuit Breaker

ABB 1SDA071353R1 is a SACE Emax 2 E1.2N 630 A fixed four-pole air circuit breaker with front terminals and an Ekip Dip LSIG solid-state electronic trip unit for comprehensive low-voltage distribution protection.

SKU: 1SDA071353R1MPN: 1SDA071353R1
Price
List Price £7,623.89 ex VAT
Your Price (ex VAT) Save 25%
£5,717.92 25% OFF
You save £1,905.97 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,717.92
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,717.92

Why Choose the ABB E1.2N 630 Ekip Dip LSIG 4p F F Air Circuit Breaker?

The ABB E1.2N 630 Ekip Dip LSIG 4p F F, order code 1SDA071353R1, is a compact SACE Emax 2 air circuit breaker (ACB) designed for comprehensive protection and switching in low-voltage electrical distribution systems. This fixed four-pole E1.2N breaker combines a 630 A rated uninterrupted current with ABB's Ekip Dip LSIG solid-state electronic trip unit.

The Ekip Dip LSIG release provides adjustable long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection. Protection thresholds are configured using DIP switches, providing straightforward adjustment while supporting selective coordination and comprehensive fault protection throughout the electrical distribution system.

The E1.2N performance level provides an ultimate short-circuit breaking capacity of 66 kA at 380–440 V AC and 50 kA at 500/525 V AC and 690 V AC. Its fixed four-pole construction with front terminals makes it suitable for three-phase four-wire systems requiring neutral switching together with integrated earth-fault protection.

Key Advantages

  • Compact ABB SACE Emax 2 E1.2N air circuit breaker.
  • 630 A rated uninterrupted current for low-voltage power distribution.
  • 66 kA ultimate short-circuit breaking capacity at 380–440 V AC.
  • Reliable Ekip Dip LSIG solid-state electronic trip unit.
  • LSIG protection covers overload, selective short circuit, instantaneous short circuit and earth fault.
  • Adjustable protection thresholds support effective coordination within distribution systems.
  • Four-pole configuration supports switching of three phases and neutral.
  • Fixed construction with front terminals supports straightforward switchboard integration.

Key Features

  • ABB SACE Emax 2 E1.2N series.
  • 630 A rated uninterrupted current.
  • Four-pole fixed configuration.
  • Ekip Dip LSIG solid-state electronic protection release.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 50/60 Hz operating frequency.
  • 66 kA Icu at 380–440 V AC.
  • 50 kA Icu at 500/525 V AC and 690 V AC.
  • Adjustable long-time, short-time, instantaneous and earth-fault protection.
  • DIP-switch protection adjustment.
  • Front main terminals for fixed switchboard installation.
  • Four auxiliary contacts with breaker open/closed position indication.

Comprehensive LSIG Circuit Protection

The ABB Ekip Dip LSIG trip unit combines four key electronic protection functions within a straightforward DIP-switch interface. Long-time protection responds to sustained overloads, short-time protection supports selective coordination, instantaneous protection responds rapidly to severe short circuits, and earth-fault protection helps safeguard the installation against current flowing to earth.

Protection thresholds can be adjusted to suit the characteristics of the electrical network, including long-time settings from 0.4–1 × In, short-time settings from 0.6–10 × In, instantaneous settings from 1.5–15 × In and earth-fault settings from 0.1–1 × In. Combined with the E1.2N frame's strong short-circuit performance, this makes the 1SDA071353R1 a versatile solution for demanding low-voltage distribution switchboards.

Typical Applications

  • Low-voltage power distribution switchboards.
  • Main incoming and feeder circuit protection.
  • Industrial manufacturing and process facilities.
  • Commercial building electrical distribution.
  • Infrastructure and utility installations.
  • Critical power distribution systems.
  • Three-phase four-wire networks requiring neutral switching and earth-fault protection.

Technical Specifications

Series SACE Emax 2 E1.2
Order code / MPN 1SDA071353R1
EAN 8015644752033
Product type Air circuit breaker
Performance level N
Rated uninterrupted current (Iu) 630 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50 / 60 Hz
Number of poles 4
Installation Fixed
Main terminals Front
Trip unit Ekip Dip LSIG
Release type Solid-state electronic
Protection functions Long-time, short-time, instantaneous and earth fault
Overload protection adjustment 0.4–1 × In
Selective short-circuit protection adjustment 0.6–10 × In
Instantaneous short-circuit protection adjustment 1.5–15 × In
Earth-fault protection adjustment 0.1–1 × In
Protection adjustment method DIP switches
Ultimate breaking capacity (Icu) at 380 V AC 66 kA
Ultimate breaking capacity (Icu) at 400/415 V AC 66 kA
Ultimate breaking capacity (Icu) at 440 V AC 66 kA
Ultimate breaking capacity (Icu) at 500/525 V AC 50 kA
Ultimate breaking capacity (Icu) at 690 V AC 50 kA
Auxiliary contacts 4
Breaker position indication Open / closed
Product net width 280 mm
Product net height 296 mm
Product net depth 183 mm
Product net weight 16 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071353R1 used for?

It is a SACE Emax 2 air circuit breaker designed for comprehensive protection, switching and selective coordination in low-voltage electrical distribution systems.

What is the current rating of this circuit breaker?

The E1.2N 630 has a rated uninterrupted current of 630 A.

Which protection unit is fitted to the 1SDA071353R1?

The breaker is equipped with an Ekip Dip LSIG solid-state electronic trip unit providing adjustable long-time, short-time, instantaneous and earth-fault protection.

What is the breaking capacity of the ABB E1.2N 630?

The E1.2N configuration provides an ultimate short-circuit breaking capacity of 66 kA at 400/415 V AC and 50 kA at 690 V AC.

How is the ABB 1SDA071353R1 installed?

The 1SDA071353R1 is a fixed four-pole air circuit breaker with front terminals, making it suitable for integration into three-phase four-wire low-voltage switchboards.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine comprehensive electronic protection, flexible selectivity and strong short-circuit performance for dependable industrial, commercial, infrastructure and critical low-voltage power-distribution systems.