1SDA071340R1 ABB E1.2B 630 Ekip G Hi-Touch LSIG 4p F F Air Circuit Breaker

1SDA071340R1 ABB E1.2B 630 Ekip G Hi-Touch LSIG 4p F F Air Circuit Breaker

ABB 1SDA071340R1 is a SACE Emax 2 E1.2B 630 A fixed four-pole air circuit breaker with front terminals and an Ekip G Hi-Touch LSIG electronic trip unit for advanced low-voltage distribution and generator protection.

SKU: 1SDA071340R1MPN: 1SDA071340R1
Price
List Price £10,292.28 ex VAT
Your Price (ex VAT) Save 25%
£7,719.21 25% OFF
You save £2,573.07 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,719.21
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,719.21

Why Choose the ABB E1.2B 630 Ekip G Hi-Touch LSIG 4p F F Air Circuit Breaker?

The ABB E1.2B 630 Ekip G Hi-Touch LSIG 4p F F, order code 1SDA071340R1, is a compact SACE Emax 2 air circuit breaker (ACB) designed for advanced protection, monitoring and control of low-voltage distribution and generator systems. This fixed four-pole E1.2B breaker combines a 630 A rated uninterrupted current with ABB's sophisticated Ekip G Hi-Touch LSIG electronic trip unit.

The Ekip G Hi-Touch LSIG release provides long-time, short-time, instantaneous and earth-fault protection together with advanced generator-oriented protection functions. Its touchscreen interface supports intuitive configuration and monitoring, while the Hi-Touch platform provides enhanced measurement and power-quality analysis capabilities for demanding electrical installations.

The E1.2B performance level provides an ultimate short-circuit breaking capacity of 42 kA at 400 V AC. Its fixed four-pole construction with front terminals is suitable for three-phase four-wire systems requiring neutral switching, comprehensive LSIG protection and advanced generator protection functionality.

Key Advantages

  • Compact ABB SACE Emax 2 E1.2B air circuit breaker.
  • 630 A rated uninterrupted current for low-voltage electrical distribution.
  • 42 kA ultimate short-circuit breaking capacity at 400 V AC.
  • Advanced Ekip G Hi-Touch LSIG electronic trip unit for distribution and generator applications.
  • LSIG protection covers overload, selective short circuit, instantaneous short circuit and earth fault.
  • Four-pole configuration supports switching of three phases and neutral.
  • Advanced measurement and power-quality analysis capabilities support detailed system monitoring.
  • Fixed construction with front terminals supports straightforward switchboard integration.

Key Features

  • ABB SACE Emax 2 E1.2B series.
  • 630 A rated uninterrupted current.
  • Four-pole fixed configuration.
  • Ekip G Hi-Touch LSIG electronic protection release.
  • 690 V AC rated voltage.
  • Long-time overload protection.
  • Short-time selective short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • Generator-oriented protection functionality.
  • 42 kA Icu at 400 V AC.
  • Four auxiliary change-over contacts for breaker status signalling.
  • Front main terminals for fixed switchboard installation.

Advanced Generator and Distribution Protection

The ABB Ekip G Hi-Touch LSIG trip unit combines comprehensive electronic circuit protection with advanced functionality developed for generator applications. Long-time, short-time, instantaneous and earth-fault protection enables the breaker to respond effectively to overloads and fault conditions while supporting selective coordination throughout the electrical distribution system.

The Emax 2 platform combines protection with advanced monitoring, measurement and communication capabilities, while the Hi-Touch release supports sophisticated power-quality analysis. Together with its compact four-pole E1.2 construction, these capabilities make the 1SDA071340R1 well suited to generator switchboards and distribution systems where neutral switching, system visibility and dependable protection are required.

Typical Applications

  • Generator protection and generator switchboards.
  • Low-voltage power distribution switchboards.
  • Main incoming and feeder circuit protection.
  • Industrial manufacturing and process facilities.
  • Commercial building electrical distribution.
  • Infrastructure and critical power installations.
  • Four-wire networks requiring neutral switching and earth-fault protection.

Technical Specifications

Series SACE Emax 2 E1.2
Order code / MPN 1SDA071340R1
EAN 8015644751906
Product type Air circuit breaker
Performance level B
Rated uninterrupted current (Iu) 630 A
Rated voltage 690 V AC
Number of poles 4
Installation Fixed
Main terminals Front
Main circuit connection Bolt connection
Trip unit Ekip G Hi-Touch LSIG
Release type Electronic
Protection functions Long-time, short-time, instantaneous and earth fault
Overload protection adjustment range 252–630 A
Short-time delayed short-circuit adjustment range 378–6300 A
Instantaneous short-circuit adjustment range 945–9450 A
Integrated earth-fault protection Yes
Ultimate breaking capacity (Icu) at 400 V AC 42 kA
Auxiliary contacts 4 change-over contacts
Breaker status indication Open / closed
Trip indication Yes
Motor operator Optional
Degree of protection IP30
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071340R1 used for?

It is a SACE Emax 2 air circuit breaker designed for advanced protection, monitoring and control of low-voltage distribution and generator systems.

What is the current rating of this circuit breaker?

The E1.2B 630 has a rated uninterrupted current of 630 A.

Which protection unit is fitted to the 1SDA071340R1?

The breaker is equipped with an Ekip G Hi-Touch LSIG electronic trip unit providing long-time, short-time, instantaneous and earth-fault protection together with advanced generator-oriented functionality.

What is the breaking capacity of the ABB E1.2B 630?

The E1.2B configuration provides an ultimate short-circuit breaking capacity of 42 kA at 400 V AC.

Is the ABB 1SDA071340R1 a four-pole fixed circuit breaker?

Yes. The 1SDA071340R1 is a fixed four-pole air circuit breaker with front terminals, making it suitable for three-phase four-wire systems requiring neutral switching.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, compact construction and sophisticated monitoring capabilities for dependable operation in industrial, commercial, infrastructure and power-generation electrical systems.