ABB 1SDA071331R1 SACE Emax 2 E1.2B 630 four-pole fixed air circuit breaker with front terminals, Ekip Dip LI electronic protection, 630 A rated current and 42 kA ultimate breaking capacity.
£4,168.07
The ABB E1.2B 630 Ekip Dip LI 4p F F, order code 1SDA071331R1, is a compact SACE Emax 2 air circuit breaker (ACB) designed for protection, switching and isolation in low-voltage electrical distribution systems. This fixed four-pole E1.2B breaker has a 630 A rated uninterrupted current and is equipped with an Ekip Dip LI solid-state electronic release.
The Ekip Dip LI trip unit provides long-time overload and instantaneous short-circuit protection. Its adjustable long-time setting allows the breaker to be coordinated with the protected circuit, while the instantaneous function provides rapid operation during severe short-circuit conditions.
The E1.2B performance level provides an ultimate short-circuit breaking capacity of 42 kA across rated AC voltages from 400 to 690 V, together with a 42 kA short-time withstand current for 1 s. The four-pole fixed construction, front terminals and compact E1.2 frame make this configuration suitable for distribution boards, industrial switchboards and other applications requiring four-pole circuit switching and protection.
The ABB SACE Emax 2 E1.2B combines circuit switching and isolation with electronic protection in a compact air circuit breaker platform. Its 630 A rated current, four-pole configuration and 42 kA ultimate breaking capacity make it suitable for incoming feeders, distribution circuits and other switchboard positions where dependable overload and short-circuit protection are required.
The Ekip Dip LI release provides adjustable long-time overload protection together with instantaneous short-circuit protection. This combination allows the breaker to respond to sustained overcurrent conditions and rapidly interrupt severe faults, helping protect conductors, busbars and connected electrical equipment from damaging fault currents.
| Series | SACE Emax 2 |
|---|---|
| Frame | E1.2B |
| ABB order code | 1SDA071331R1 |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 630 A |
| Rated voltage | 690 V AC |
| Number of poles | 4 |
| Short-circuit performance level | B |
| Trip unit | Ekip Dip LI |
| Release type | Electronic / solid-state |
| Protection functions | L and I |
| Overload release adjustment | 252–630 A |
| Instantaneous short-circuit adjustment | 945–9450 A |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 42 kA |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 42 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 42 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500 V AC | 42 kA |
| Ultimate short-circuit breaking capacity (Icu) at 525 V AC | 42 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 42 kA |
| Service short-circuit breaking capacity (Ics) | 100% of Icu |
| Short-time withstand current (Icw), 1 s | 42 kA |
| Short-time withstand current (Icw), 3 s | 24 kA |
| Execution | Fixed |
| Terminal arrangement | Front terminals |
| Terminal type | Bolt |
| Terminal tightening torque | 45 N·m |
| Auxiliary contacts | 4 |
| Suitable for IT networks | Yes, up to 690 V AC |
| Electrical durability | 8000 operating cycles |
| Mechanical durability | 20000 operating cycles |
| Dimensions (W × H × D) | 284 × 295 × 184 mm |
| Net weight | 11 kg |
| Standard | IEC |
| EAN | 8015644751814 |
| ABB product group | Emax2 Air Circuit Breaker |
The ABB 1SDA071331R1 is a SACE Emax 2 E1.2B 630 Ekip Dip LI four-pole fixed air circuit breaker with front terminals, a 630 A rated uninterrupted current and an electronic Ekip Dip LI protection release.
The breaker has a rated uninterrupted current of 630 A and an adjustable long-time overload protection range of 252–630 A.
The Ekip Dip LI solid-state release provides long-time overload (L) and instantaneous short-circuit (I) protection. This LI version does not incorporate the additional short-time or ground-fault functions found on LSI and LSIG releases.
The E1.2B 630 has an ultimate short-circuit breaking capacity of 42 kA from 400 to 690 V AC, with a 42 kA short-time withstand current for 1 s.
It is typically used in low-voltage distribution boards, industrial switchboards, incoming feeders and four-pole distribution circuits requiring reliable overload and instantaneous short-circuit protection.
ABB SACE Emax 2 air circuit breakers combine compact construction, electronic protection and dependable switching performance, providing a flexible solution for industrial, commercial and infrastructure low-voltage distribution systems.