1SDA071329R1 ABB E1.2N 250 Ekip Hi-Touch LSIG 4-Pole Air Circuit Breaker

1SDA071329R1 ABB E1.2N 250 Ekip Hi-Touch LSIG 4-Pole Air Circuit Breaker

ABB 1SDA071329R1 is a SACE Emax 2 E1.2N 250 A fixed four-pole air circuit breaker with front terminals and an Ekip Hi-Touch LSIG electronic trip unit for advanced low-voltage power distribution protection.

SKU: 1SDA071329R1MPN: 1SDA071329R1
Price
List Price £11,736.79 ex VAT
Your Price (ex VAT) Save 25%
£8,802.59 25% OFF
You save £2,934.20 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,802.59
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,802.59

Why Choose the ABB 1SDA071329R1 E1.2N 250 Ekip Hi-Touch LSIG Air Circuit Breaker?

The ABB 1SDA071329R1 is a compact, high-performance SACE Emax 2 E1.2N air circuit breaker designed for advanced protection, switching and monitoring in low-voltage power distribution systems. Rated at 250 A, this four-pole fixed breaker combines the E1.2N frame with ABB's advanced Ekip Hi-Touch LSIG electronic trip unit.

The Ekip Hi-Touch LSIG release provides long-time overload (L), short-time selective short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection. The Hi-Touch platform combines sophisticated protection, measurement and monitoring capabilities with a touchscreen interface, supporting accurate configuration and enhanced supervision of critical electrical distribution systems.

The 1SDA071329R1 is supplied in a fixed four-pole configuration with front terminals. With a rated operational voltage of up to 690 V AC, an ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and a rated short-time withstand current of 50 kA for 1 s, it provides robust protection for industrial, commercial and infrastructure power distribution installations.

Key Advantages

  • Compact 250 A SACE Emax 2 air circuit breaker for low-voltage power distribution.
  • E1.2N performance level with high short-circuit capability in a compact frame.
  • Advanced Ekip Hi-Touch LSIG electronic protection release.
  • Long-time, short-time, instantaneous and earth-fault protection functions.
  • 66 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 50 kA short-time withstand current for 1 s.
  • Four-pole construction with 100% neutral-pole current capability.
  • Fixed configuration with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Emax 2 E1.2N series.
  • 250 A rated uninterrupted current.
  • 4-pole fixed configuration.
  • Front terminal connection.
  • Ekip Hi-Touch LSIG electronic trip unit.
  • Long-time overload protection (L).
  • Short-time selective short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Earth-fault protection (G).
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 66 kA Icu at 400–440 V AC.
  • 50 kA Icw for 1 s.
  • Suitable for IT networks up to 690 V.

Advanced LSIG Protection for Low-Voltage Distribution

Air circuit breakers such as the ABB SACE Emax 2 E1.2N provide switching, isolation and fault protection for low-voltage electrical distribution networks. The compact E1.2 platform combines substantial short-circuit performance with advanced electronic protection, enabling switchboard designers to achieve dependable protection while reducing the space required for major distribution equipment.

The Ekip Hi-Touch LSIG electronic release provides configurable protection against overloads, delayed and instantaneous short circuits and earth faults. Combined with advanced measurement and monitoring capabilities, this makes the 1SDA071329R1 suitable for installations where system selectivity, electrical visibility and comprehensive fault protection are important.

Typical Applications

  • Low-voltage switchboard incomer protection.
  • Industrial power distribution systems.
  • Commercial building electrical distribution.
  • Transformer and installation protection.
  • Feeder and distribution circuit protection.
  • Manufacturing and process facilities.
  • Data centres and critical infrastructure.
  • Compact switchgear and power distribution assemblies.

Technical Specifications

Series SACE Emax 2
Frame E1.2N
ABB order code 1SDA071329R1
EAN 8015644751791
Product type Air circuit breaker
Rated current (In) 250 A
Rated uninterrupted current (Iu) 250 A
Number of poles 4
Neutral pole current 100% of Iu
Installation Fixed
Terminal connection Front
Trip unit Ekip Hi-Touch LSIG
Release type Electronic
Protection functions Long-time (L), short-time (S), instantaneous (I), earth fault (G)
Current type AC
Rated operational voltage (Ue) up to 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) at 400–440 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 500–525 V AC 50 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 50 kA
Service short-circuit breaking capacity (Ics) 50 kA
Rated short-time withstand current (Icw) 50 kA for 1 s; 30 kA for 3 s
Electrical durability 8000 cycles
Mechanical durability 20000 cycles
Power loss 31 W
Connecting capacity 120 mm²
Dimensions (W × H × D) 280 × 296 × 183 mm
Net weight approx. 16 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071329R1?

The ABB 1SDA071329R1 is a SACE Emax 2 E1.2N 250 A four-pole fixed air circuit breaker with front terminals and an Ekip Hi-Touch LSIG electronic protection release.

What is the rated current of the ABB 1SDA071329R1?

The breaker has a rated uninterrupted current of 250 A and is designed for low-voltage power distribution and installation protection.

What protection functions does the Ekip Hi-Touch LSIG trip unit provide?

The Ekip Hi-Touch LSIG release provides long-time overload (L), short-time selective short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection.

What is the breaking capacity of the ABB E1.2N 250?

The E1.2N 250 has an ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 500–690 V AC.

Is the ABB 1SDA071329R1 a three-pole or four-pole breaker?

The 1SDA071329R1 is a four-pole air circuit breaker with a neutral pole rated at 100% of the breaker's uninterrupted current.

Is the ABB 1SDA071329R1 fixed or withdrawable?

This model is a fixed air circuit breaker with front terminals, designed for permanent installation in a suitable low-voltage switchboard or distribution assembly.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers combine compact construction, advanced electronic protection, measurement capabilities and dependable short-circuit performance for industrial, commercial and infrastructure low-voltage power distribution systems.