1SDA071294R1 ABB E6.2H 6300 Ekip Touch LI 3p F HR Air Circuit Breaker 6300 A

1SDA071294R1 ABB E6.2H 6300 Ekip Touch LI 3p F HR Air Circuit Breaker 6300 A

ABB 1SDA071294R1 Emax 2 E6.2H 6300 Ekip Touch LI three-pole fixed air circuit breaker with a 6300 A rated current, 690 V AC rated operational voltage and 100 kA ultimate short-circuit breaking capacity.

SKU: 1SDA071294R1MPN: 1SDA071294R1
Price
List Price £45,586.24 ex VAT
Your Price (ex VAT) Save 25%
£34,189.68 25% OFF
You save £11,396.56 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £34,189.68
Trade pricing is personalised to your account

Manufacturer Lead Time

£34,189.68

Why Choose the ABB E6.2H 6300 Ekip Touch LI 3p F HR Air Circuit Breaker?

The ABB E6.2H 6300 Ekip Touch LI 3p F HR, order code 1SDA071294R1, is a high-performance three-pole air circuit breaker (ACB) designed for switching and protection in demanding low-voltage power distribution systems. As part of the advanced ABB SACE Emax 2 series, this fixed circuit breaker combines a 6300 A rated current, high short-circuit performance and the electronic Ekip Touch LI protection release.

Designed for high-current industrial, infrastructure and commercial electrical installations, the E6.2H provides dependable protection against overload and short-circuit conditions. The integrated Ekip Touch LI electronic trip unit provides long-time overload and instantaneous short-circuit protection, with an intuitive touchscreen interface for configuring protection settings and monitoring the electrical system.

With a rated operational voltage of up to 690 V AC and an ultimate short-circuit breaking capacity of 100 kA at 400/415 V AC, the E6.2H 6300 is engineered for high-power installations requiring reliable interruption of substantial fault currents. This version features a fixed three-pole configuration with rear flat horizontal terminals for integration into low-voltage switchboards and high-current power distribution assemblies.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage distribution systems.
  • 6300 A rated current for very high-current electrical installations.
  • 100 kA Icu at 400/415 V AC short-circuit breaking capacity.
  • Advanced Ekip Touch LI electronic protection release with touchscreen interface.
  • Long-time overload and instantaneous short-circuit protection functions.
  • Three-pole fixed construction for dependable switchboard installation.
  • Rear flat horizontal terminals simplify integration into high-current distribution assemblies.
  • Four auxiliary contacts provide circuit breaker status signalling.

Key Features

  • ABB SACE Emax 2 E6.2H series.
  • 6300 A rated current.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 100 kA Icu at 400/415 V AC.
  • 100 kA Icu at 690 V AC.
  • 100 kA short-time withstand current for 1 s and 3 s.
  • Ekip Touch LI solid-state electronic release for long-time and instantaneous protection.
  • Adjustable overload and instantaneous short-circuit protection settings.
  • Three-pole fixed configuration with rear flat horizontal terminals.
  • Four changeover auxiliary contacts for circuit breaker status signalling.

Reliable Protection for High-Power Distribution Systems

Air circuit breakers such as the ABB Emax 2 E6.2H provide switching and protection for very high-current low-voltage electrical distribution systems. By detecting overload and short-circuit conditions and interrupting fault current, the breaker helps protect transformers, switchboards, busbars, cables and connected electrical equipment from potentially damaging electrical faults.

The Ekip Touch LI release combines long-time overload protection with instantaneous short-circuit protection and an intuitive electronic interface. Its adjustable protection settings enable the breaker to be configured for the requirements of the installation, while the E6.2H platform provides the high current-carrying capacity and fault interruption performance required for demanding industrial and infrastructure applications.

Typical Applications

  • Main incoming protection for high-current low-voltage switchboards.
  • Industrial power distribution systems.
  • High-current electrical distribution panels and busbar systems.
  • Transformer and installation protection.
  • Manufacturing and process industry installations.
  • Commercial and infrastructure power distribution.
  • Critical power and utility distribution systems.
  • Large industrial plant electrical systems.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA071294R1
Product type Air circuit breaker
Frame / sub-type E6.2
Performance level H
Rated current (In) 6300 A
Rated uninterrupted current (Iu) 6300 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 100 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw) 100 kA for 1 s / 100 kA for 3 s
Overload protection adjustment range 2520–6300 A
Instantaneous short-circuit protection adjustment range 9450–94500 A
Number of poles 3P
Current type AC
Trip unit Ekip Touch LI solid-state electronic release
Protection functions Long-time overload (L) and instantaneous short-circuit (I)
Integrated earth-fault protection No
Mounting type Fixed
Main circuit connection Bolted connection
Terminal type Rear flat horizontal
Main circuit screw M12
Terminal tightening torque 70 N·m
Auxiliary contacts 4 changeover contacts
Motor operator Optional
Power loss 767 W
Mechanical durability 12,000 cycles
Electrical durability at ≤440 V 2,000 cycles
Electrical durability at 500–690 V 2,000 cycles
Dimensions (W × H × D) 762 × 371 × 270 mm
Weight 109 kg
EAN 8015644751449

Frequently Asked Questions

What is the ABB 1SDA071294R1 used for?

The ABB 1SDA071294R1 is a high-current air circuit breaker designed for switching and protecting low-voltage electrical distribution systems against overload and short-circuit conditions.

What is the rated current of the ABB E6.2H 6300?

This Emax 2 air circuit breaker has a rated current of 6300 A, making it suitable for very high-current industrial, infrastructure and commercial power distribution systems.

What is the breaking capacity of the ABB 1SDA071294R1?

The E6.2H 6300 has an ultimate short-circuit breaking capacity of 100 kA at 400/415 V AC and maintains a 100 kA Icu at 690 V AC.

What protection functions does the Ekip Touch LI release provide?

The Ekip Touch LI electronic release provides long-time overload (L) and instantaneous short-circuit (I) protection, with adjustable electronic settings and a touchscreen interface.

Is the ABB 1SDA071294R1 fixed or withdrawable?

The 1SDA071294R1 is a fixed three-pole air circuit breaker equipped with rear flat horizontal terminals for installation in low-voltage switchboards.

Trusted High-Performance Circuit Protection

ABB SACE Emax 2 air circuit breakers are engineered for demanding low-voltage power distribution systems, combining high current capacity, strong interruption performance and advanced electronic protection for industrial, infrastructure and commercial electrical installations.