ABB 1SDA071270R1 Emax 2 E6.2H 5000 Ekip G Hi-Touch LSIG three-pole fixed air circuit breaker with a 5000 A rated current, 690 V AC rated operational voltage and 100 kA short-circuit breaking capacity for generator and power distribution protection.
£30,228.42
The ABB E6.2H 5000 Ekip G Hi-Touch LSIG 3p F HR, order code 1SDA071270R1, is a high-performance three-pole air circuit breaker (ACB) designed for generator protection and demanding low-voltage power distribution systems. As part of the advanced ABB SACE Emax 2 series, this fixed circuit breaker combines a 5000 A rated current, high short-circuit performance and the sophisticated Ekip G Hi-Touch LSIG electronic protection release.
Designed for high-current generator and power distribution applications, the E6.2H provides comprehensive protection against overload, short-circuit and earth-fault conditions. The integrated Ekip G Hi-Touch LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, together with advanced measurement and protection capabilities for demanding electrical installations.
With a rated operational voltage of up to 690 V AC and an ultimate short-circuit breaking capacity of 100 kA at 440 V AC, the E6.2H 5000 is engineered for high-power systems requiring dependable fault interruption and generator-specific protection. This version features a fixed three-pole configuration with rear flat horizontal terminals for integration into low-voltage switchboards and high-current power distribution assemblies.
Air circuit breakers such as the ABB Emax 2 E6.2H provide switching and protection for high-current low-voltage electrical systems. By detecting overload, short-circuit and earth-fault conditions and interrupting fault current, the breaker helps protect generators, transformers, switchboards, cables and connected electrical equipment from potentially damaging electrical faults.
The Ekip G Hi-Touch LSIG release is designed to provide advanced protection and monitoring for generator applications. Its long-time, short-time, instantaneous and earth-fault protection functions enable comprehensive coordination within complex electrical networks, while the Emax 2 platform supports integration with modern automation and energy management systems.
| Series | SACE Emax 2 |
|---|---|
| Order code / MPN | 1SDA071270R1 |
| Product type | Air circuit breaker |
| Frame / sub-type | E6.2 |
| Performance level | H |
| Rated current | 5000 A |
| Rated uninterrupted current (Iu) | 5000 A |
| Rated operational voltage | 690 V AC |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 100 kA |
| Rated short-time withstand current (Icw) for 1 s | 100 kA |
| Number of poles | 3P |
| Current type | AC |
| Trip unit | Ekip G Hi-Touch LSIG electronic release |
| Protection functions | Long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) |
| Earth-fault protection | Yes |
| Mounting type | Fixed |
| Main circuit connection | Rear flat horizontal |
| Terminal orientation | Horizontal rear connection |
| Auxiliary contacts | 4 |
| Trip signalling contact | 1 |
| Standards / approvals | IEC |
| Dimensions | 762 × 371 × 270 mm |
| Weight | approx. 109 kg |
| Country of origin | Italy |
The ABB 1SDA071270R1 is a high-current air circuit breaker designed for generator protection and low-voltage power distribution systems, providing protection against overload, short-circuit and earth-fault conditions.
This Emax 2 air circuit breaker has a rated current of 5000 A, making it suitable for high-current generator, industrial and infrastructure power distribution applications.
The E6.2H 5000 has an ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 100 kA for 1 s.
The Ekip G Hi-Touch LSIG electronic release provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection, together with advanced protection and measurement functions for generator applications.
The 1SDA071270R1 is a fixed three-pole air circuit breaker equipped with rear flat horizontal terminals for installation in low-voltage switchboards and generator distribution assemblies.
ABB SACE Emax 2 air circuit breakers combine high interruption performance, advanced electronic protection, measurement and automation capabilities for demanding generator, industrial and infrastructure power distribution systems.