1SDA071237R1 ABB E6.2H 4000 Ekip G Touch LSIG 3p FHR Air Circuit Breaker

1SDA071237R1 ABB E6.2H 4000 Ekip G Touch LSIG 3p FHR Air Circuit Breaker

ABB 1SDA071237R1 is a SACE Emax 2 E6.2H 4000 A fixed three-pole air circuit breaker with rear horizontal terminals, an Ekip G Touch LSIG electronic trip unit, 100 kA ultimate short-circuit breaking capacity at 440 V AC and 100 kA one-second short-time withstand capability.

SKU: 1SDA071237R1MPN: 1SDA071237R1
Price
List Price £23,329.12 ex VAT
Your Price (ex VAT) Save 25%
£17,496.84 25% OFF
You save £5,832.28 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £17,496.84
Trade pricing is personalised to your account

Manufacturer Lead Time

£17,496.84

Why Choose the ABB E6.2H 4000 Ekip G Touch LSIG 3p FHR Air Circuit Breaker?

The ABB E6.2H 4000 Ekip G Touch LSIG 3p FHR, order code 1SDA071237R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for advanced protection, switching and control in demanding low-voltage generator and power distribution systems. Rated at 4000 A, this three-pole fixed circuit breaker combines ABB's E6.2H frame with the advanced Ekip G Touch LSIG electronic trip unit.

The Ekip G Touch LSIG release provides comprehensive long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection. The generator-oriented Ekip G platform is designed for applications requiring sophisticated protection and supervision, making this breaker particularly suitable for generator switchboards, critical power systems and high-current distribution networks.

This configuration is a fixed three-pole breaker with rear horizontal (HR) terminals. The E6.2H 4000 provides an ultimate short-circuit breaking capacity of 100 kA at 440 V AC together with a rated short-time withstand current of 100 kA for 1 s, delivering substantial fault-handling capability for demanding power-generation and distribution installations.

Key Advantages

  • High-capacity 4000 A SACE Emax 2 air circuit breaker for major low-voltage power circuits.
  • Advanced Ekip G Touch LSIG electronic trip unit for generator and critical power applications.
  • 100 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 100 kA short-time withstand current for 1 s for demanding high-fault-level systems.
  • LSIG functionality provides overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection.
  • Short-time protection supports selective coordination between upstream and downstream protective devices.
  • Three-pole fixed configuration with rear horizontal connections for switchboard integration.
  • Generator-oriented Ekip G Touch technology supports sophisticated protection and electrical system supervision.

Key Features

  • ABB SACE Emax 2 E6.2H frame.
  • 4000 A rated uninterrupted current.
  • Three-pole configuration.
  • Fixed mounting version.
  • Ekip G Touch LSIG electronic release.
  • Long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection.
  • 100 kA Icu at 440 V AC.
  • 100 kA Icw for 1 s.
  • Rear horizontal (HR) main terminals.
  • Generator-oriented protection functionality.
  • High-performance H breaking-capacity class.
  • Designed for high-current generator, transformer and main distribution applications.

Advanced Generator Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 provide switching, isolation and fault protection for major low-voltage electrical circuits. The E6.2H frame combines a substantial 4000 A current rating with 100 kA ultimate breaking capacity at 440 V AC and 100 kA one-second short-time withstand capability, making it suitable for installations with significant prospective fault currents.

The Ekip G Touch LSIG trip unit combines long-time, short-time and instantaneous overcurrent protection with integrated earth-fault protection and generator-oriented functionality. This comprehensive protection architecture supports selective coordination and effective fault management in generator and critical power systems, helping correctly engineered installations isolate faults while maintaining continuity of supply to unaffected circuits.

Typical Applications

  • Generator protection and generator distribution switchboards.
  • Power-generation and standby power systems.
  • High-current industrial low-voltage switchboards.
  • Main incomer and 4000 A feeder protection.
  • Transformer secondary distribution systems.
  • Manufacturing and process-industry electrical installations.
  • Data centres and critical electrical infrastructure.
  • Systems requiring generator-oriented LSIG protection, selectivity and integrated earth-fault protection.

Technical Specifications

Series SACE Emax 2
Frame E6.2H
ABB order code 1SDA071237R1
Product type Air circuit breaker
Rated uninterrupted current (Iu) 4000 A
Number of poles 3
Trip unit Ekip G Touch LSIG
Release type Electronic
Protection functions L, S, I and G
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated short-time withstand current (Icw, 1 s) 100 kA
Short-circuit performance level H
Integrated earth-fault protection Yes
Generator-oriented protection Yes
Installation Fixed
Terminal configuration Rear horizontal (HR)
Product net weight 109 kg
Product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA071237R1?

The ABB 1SDA071237R1 is a SACE Emax 2 E6.2H fixed three-pole air circuit breaker rated at 4000 A and equipped with an Ekip G Touch LSIG electronic trip unit.

What protection functions does the Ekip G Touch LSIG trip unit provide?

The Ekip G Touch LSIG release provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection together with functionality for generator and critical power applications.

What is the current rating of the ABB E6.2H 1SDA071237R1?

The circuit breaker has a rated uninterrupted current of 4000 A.

What is the breaking capacity of the ABB E6.2H 4000?

The E6.2H 4000 configuration has an ultimate short-circuit breaking capacity of 100 kA at 440 V AC.

What is the short-time withstand rating of the ABB 1SDA071237R1?

The E6.2H 4000 has a rated short-time withstand current of 100 kA for 1 s, supporting demanding high-current and selectively coordinated distribution systems.

Does the ABB 1SDA071237R1 provide earth-fault protection?

Yes. The G function within the Ekip G Touch LSIG release provides integrated earth-fault protection in addition to long-time, short-time and instantaneous overcurrent protection.

Is the ABB 1SDA071237R1 suitable for generator applications?

Yes. The Ekip G Touch release is intended for generator-oriented protection applications, making this configuration suitable for generator switchboards, power-generation systems and critical power distribution networks.

What does FHR mean for the ABB 1SDA071237R1?

This configuration is a fixed circuit breaker with rear horizontal terminals, providing rear-facing main connections suitable for integration with switchboard busbars and power conductors.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers combine high-current switching and protection with advanced electronic trip technology, generator-oriented protection and sophisticated power-management capabilities for demanding industrial, infrastructure, critical power and power-generation applications worldwide.