1SDA071228R1 ABB E4.2V 4000 Ekip Hi-Touch LSI 3p FHR Air Circuit Breaker

1SDA071228R1 ABB E4.2V 4000 Ekip Hi-Touch LSI 3p FHR Air Circuit Breaker

ABB 1SDA071228R1 Emax 2 E4.2V 4000 Ekip Hi-Touch LSI three-pole fixed air circuit breaker with a 4000 A rated uninterrupted current, 690 V AC operational voltage, 150 kA breaking capacity at 400–440 V AC and advanced LSI electronic protection for high-current low-voltage power distribution systems.

SKU: 1SDA071228R1MPN: 1SDA071228R1
Price
List Price £31,768.13 ex VAT
Your Price (ex VAT) Save 25%
£23,826.10 25% OFF
You save £7,942.03 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £23,826.10
Trade pricing is personalised to your account

Manufacturer Lead Time

£23,826.10

Why Choose the ABB E4.2V 4000 Ekip Hi-Touch LSI 3p FHR Air Circuit Breaker?

The ABB E4.2V 4000 Ekip Hi-Touch LSI 3p FHR, order code 1SDA071228R1, is a high-performance air circuit breaker (ACB) designed for advanced protection, switching and isolation in demanding high-current low-voltage power distribution systems. Part of the ABB SACE Emax 2 range, it combines a 4000 A rated uninterrupted current with the advanced Ekip Hi-Touch LSI electronic trip unit for industrial, commercial, infrastructure and critical-power installations.

The E4.2V performance level delivers exceptional short-circuit capability, providing a rated ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC and 100 kA at 500–690 V AC. Its Ekip Hi-Touch LSI electronic release provides long-time overload, selective short-time and instantaneous short-circuit protection, enabling sophisticated protection coordination across complex electrical distribution networks.

With a rated operational voltage of 690 V AC, three-pole construction and fixed installation with rear flat horizontal terminals, the 1SDA071228R1 is engineered for integration into high-capacity low-voltage switchboards and distribution assemblies. Its rated short-time withstand current of 100 kA for 1 s makes it particularly suitable for installations where high prospective fault currents, selectivity and continuity of supply are key design considerations.

Key Advantages

  • Premium ABB SACE Emax 2 E4.2V air circuit breaker for demanding low-voltage power systems.
  • 4000 A rated uninterrupted current for high-capacity switchboards and large electrical loads.
  • 150 kA Icu at 400–440 V AC provides exceptional short-circuit interruption capability.
  • 100 kA Icu at 500–690 V AC maintains high fault-breaking performance at elevated system voltages.
  • Advanced Ekip Hi-Touch LSI electronic trip unit with long-time, short-time and instantaneous protection.
  • 100 kA short-time withstand current for 1 s supports highly selective protection strategies.
  • Ics equal to 100% of Icu provides excellent service short-circuit performance.

Key Features

  • ABB SACE Emax 2 E4.2V series.
  • 4000 A rated uninterrupted current (Iu).
  • 690 V AC rated operational voltage (Ue).
  • 1000 V AC rated insulation voltage (Ui).
  • 12 kV rated impulse withstand voltage (Uimp).
  • 150 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 100 kA ultimate short-circuit breaking capacity at 500–690 V AC.
  • 100 kA rated short-time withstand current for 1 s.
  • 75 kA rated short-time withstand current for 3 s.
  • Ekip Hi-Touch LSI electronic protection release.
  • Long-time overload, selective short-time and instantaneous short-circuit protection.
  • Three-pole fixed-mounted construction.
  • Rear flat horizontal main terminals with bolted connections.
  • Four auxiliary change-over contacts.
  • Motor operator can be added as an option.
  • Suitable for IT networks up to 690 V.
  • IP30 degree of protection.

Advanced Selective Protection for High-Fault-Level Distribution

The ABB SACE Emax 2 E4.2V is engineered for high-current electrical networks where exceptional short-circuit performance and precise protection coordination are required. Its 4000 A current rating, 150 kA breaking capacity at 400–440 V AC and 100 kA one-second withstand capability make it suitable for protecting switchboards, busbars, transformers, cables and other critical components in substantial low-voltage power systems.

The Ekip Hi-Touch LSI electronic trip unit combines long-time overload, selective short-time and instantaneous short-circuit protection. The short-time function enables coordination between upstream and downstream protective devices, helping isolate the section affected by a fault while maintaining continuity of supply elsewhere in the installation. This LSI configuration is particularly appropriate where selective overcurrent protection is required without integrated earth-fault protection.

Typical Applications

  • Main incomer protection in high-capacity low-voltage switchboards.
  • Industrial power distribution systems.
  • Transformer and installation protection.
  • Data centres and critical-power installations.
  • Commercial and infrastructure electrical distribution.
  • Manufacturing facilities and process plants.
  • High-current feeder protection.
  • Low-voltage switchgear requiring advanced selective protection.

Technical Specifications

Product group Emax 2 Air Circuit Breaker
Series SACE Emax 2 E4.2
Performance level V
Order code / SKU 1SDA071228R1
EAN / GTIN 8015644750787
Product type Air circuit breaker (ACB)
Rated uninterrupted current (Iu) 4000 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Number of poles 3
Current type AC
Trip unit Ekip Hi-Touch LSI
Release type Electronic (EL)
Protection functions Long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I)
Overload protection adjustment From 1600 A
Short-time delayed protection adjustment From 2400 A
Instantaneous protection adjustment From 6000 A
Ultimate short-circuit breaking capacity (Icu) at 400 / 415 / 440 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 500 / 525 / 690 V AC 100 kA
Service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw), 1 s 100 kA
Rated short-time withstand current (Icw), 3 s 75 kA
Installation Fixed
Main terminal position Rear
Terminal configuration Rear flat horizontal
Main circuit connection Bolt connection
Recommended main-circuit screw M12
Tightening torque 70 N·m
Auxiliary contacts 4 change-over contacts
Open/closed position indication Yes
Integrated earth-fault protection No
Motor operator Optional
Degree of protection IP30
Suitable for IT networks Yes, up to 690 V
Power loss 465 W
Electrical durability at Ue ≤ 440 V 5000 cycles
Electrical durability at Ue 500–690 V 4000 cycles
Mechanical durability 15000 cycles
Product net width 384 mm
Product net height 371 mm
Product net depth 270 mm
Product net weight 56 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071228R1 used for?

The ABB 1SDA071228R1 is an Emax 2 air circuit breaker designed for switching, isolation and advanced overcurrent protection in high-current low-voltage systems, including transformer, generator and installation protection applications.

What is the current rating of the ABB E4.2V 4000?

The breaker has a rated uninterrupted current of 4000 A, making it suitable for high-capacity switchboards, main incomers, large feeders and demanding industrial power distribution systems.

What is the breaking capacity of the ABB 1SDA071228R1?

The E4.2V provides a rated ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC and 100 kA at 500–690 V AC. Its rated short-time withstand current is 100 kA for 1 s and 75 kA for 3 s.

What protection functions does the Ekip Hi-Touch LSI trip unit provide?

The Ekip Hi-Touch LSI electronic trip unit provides long-time overload, selective short-time short-circuit and instantaneous short-circuit protection. This model does not include integrated earth-fault protection.

Is the ABB 1SDA071228R1 fixed or withdrawable?

The 1SDA071228R1 is a fixed three-pole air circuit breaker with rear flat horizontal main terminals and bolted main-circuit connections for integration into low-voltage switchboards and power distribution assemblies.

Trusted Power Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance with advanced Ekip electronic protection technology, providing dependable protection, selectivity and control for high-current low-voltage power distribution systems.