1SDA071226R1 ABB E4.2V 4000 Ekip Touch LSIG 3p F HR Air Circuit Breaker

1SDA071226R1 ABB E4.2V 4000 Ekip Touch LSIG 3p F HR Air Circuit Breaker

ABB 1SDA071226R1 E4.2V 4000 Ekip Touch LSIG is a fixed three-pole 4000 A SACE Emax 2 air circuit breaker with rear horizontal terminals, 150 kA breaking capacity at 400–440 V AC and comprehensive electronic LSIG protection.

SKU: 1SDA071226R1MPN: 1SDA071226R1
Price
List Price £28,747.24 ex VAT
Your Price (ex VAT) Save 25%
£21,560.43 25% OFF
You save £7,186.81 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £21,560.43
Trade pricing is personalised to your account

Manufacturer Lead Time

£21,560.43

Why Choose the ABB E4.2V 4000 Ekip Touch LSIG 3p F HR Air Circuit Breaker?

The ABB E4.2V 4000 Ekip Touch LSIG 3p F HR, order code 1SDA071226R1, is a high-performance 4000 A three-pole air circuit breaker (ACB) designed for switching, isolation and comprehensive protection in demanding low-voltage power distribution systems. Part of the ABB SACE Emax 2 series, it combines the E4.2V high-breaking-capacity platform with fixed mounting, rear horizontal terminals and the advanced Ekip Touch LSIG electronic trip unit.

The E4.2V 4000 provides an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC and 100 kA at 500–690 V AC. Its rated short-time withstand current reaches 100 kA for 1 s, providing exceptional fault-handling capability for main distribution systems where very high prospective short-circuit currents and selective coordination are important.

Protection is provided by the Ekip Touch LSIG solid-state electronic release, delivering long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection. The breaker is supplied as a fixed three-pole unit with rear horizontal terminals and is fitted with four auxiliary contacts plus open/closed circuit-breaker position indication.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage distribution systems.
  • 4000 A rated uninterrupted current for high-current electrical installations.
  • Ekip Touch LSIG electronic trip unit with intuitive touchscreen configuration.
  • Comprehensive long-time, short-time, instantaneous and earth-fault protection.
  • 150 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 100 kA ultimate short-circuit breaking capacity at 500–690 V AC.
  • 100 kA rated short-time withstand current for 1 s.
  • Fixed three-pole construction with rear horizontal terminals for switchboard integration.

Key Features

  • ABB SACE Emax 2 E4.2V series.
  • 4000 A rated uninterrupted current.
  • Three-pole configuration.
  • Fixed mounting design.
  • Rear horizontal main terminals.
  • Ekip Touch LSIG solid-state electronic release.
  • Long-time overload protection.
  • Short-time selective short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • 150 kA Icu at 400–440 V AC.
  • 100 kA Icu at 500–690 V AC.
  • 100 kA Icw for 1 s and 75 kA Icw for 3 s.
  • Rated operational voltage up to 690 V AC.
  • Four auxiliary contacts and open/closed position indication.

Advanced LSIG Protection for High-Fault-Level Distribution

ABB SACE Emax 2 air circuit breakers provide switching, isolation and advanced electronic protection for high-current low-voltage electrical networks. The E4.2V 4000 combines a 4000 A continuous-current rating, 150 kA breaking capacity at 400–440 V AC and 100 kA one-second short-time withstand capability, making it particularly suitable for distribution systems with very high prospective fault currents.

The Ekip Touch LSIG release provides comprehensive protection against sustained overloads, delayed and instantaneous short circuits and earth faults. Adjustable protection thresholds and touchscreen configuration support effective coordination with other protective devices, helping isolate faults at the appropriate distribution level while maintaining continuity of supply to unaffected circuits.

Typical Applications

  • Main low-voltage distribution switchboards.
  • High-current industrial power distribution systems.
  • Manufacturing and process plants.
  • Large commercial and infrastructure installations.
  • Transformer-fed distribution networks.
  • Critical power and utility installations.
  • High-fault-level switchgear and power distribution assemblies.

Technical Specifications

Series SACE Emax 2
Order code 1SDA071226R1
EAN 8015644750763
Product type Air circuit breaker (ACB)
Rated uninterrupted current (Iu) 4000 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Frequency 50/60 Hz
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 100 kA
Ultimate short-circuit breaking capacity (Icu) at 525 V AC 100 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 100 kA
Service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw, 1 s) 100 kA
Rated short-time withstand current (Icw, 3 s) 75 kA
Number of poles 3
Current type AC
Mounting Fixed
Main terminal arrangement Rear horizontal
Terminal type Bolt
Main circuit connection screw M12
Trip unit Ekip Touch LSIG
Release type Solid-state electronic
Protection functions Long-time, short-time, instantaneous and earth fault
Overload protection adjustment 0.4–1 × In
Short-time protection adjustment 0.6–10 × In
Instantaneous protection adjustment 1.5–15 × In
Earth-fault protection adjustment 0.1–1 × In
Integrated earth-fault protection Yes
Auxiliary contacts 4
Breaker position indication Open / closed
Dimensions (W × H × D) 384 × 371 × 270 mm
Net weight 56 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071226R1 used for?

The ABB 1SDA071226R1 is a 4000 A air circuit breaker designed for switching, isolation and comprehensive electronic protection of high-current low-voltage power distribution circuits.

What protection unit is fitted to the ABB 1SDA071226R1?

The breaker is fitted with an ABB Ekip Touch LSIG electronic trip unit, providing long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection.

What is the rated current of the ABB E4.2V 1SDA071226R1?

The breaker has a rated uninterrupted current of 4000 A.

Is the ABB 1SDA071226R1 fixed or withdrawable?

The 1SDA071226R1 is a fixed three-pole air circuit breaker equipped with rear horizontal main terminals.

What is the breaking capacity of the ABB E4.2V 4000?

The E4.2V 4000 provides an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC and 100 kA at 500–690 V AC, with a rated short-time withstand current of 100 kA for 1 s.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers combine advanced electronic LSIG protection, flexible configuration and exceptional short-circuit performance for dependable switching and protection in demanding industrial, commercial and infrastructure low-voltage power distribution systems.